These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
143 related articles for article (PubMed ID: 15587647)
1. Accuracy of the Burns equation for stopping-power ratio as a function of depth and R50. Rogers DW Med Phys; 2004 Nov; 31(11):2961-3. PubMed ID: 15587647 [TBL] [Abstract][Full Text] [Related]
2. R50 as a beam quality specifier for selecting stopping-power ratios and reference depths for electron dosimetry. Burns DT; Ding GX; Rogers DW Med Phys; 1996 Mar; 23(3):383-8. PubMed ID: 8815381 [TBL] [Abstract][Full Text] [Related]
3. Comment on "determination of the depth of 50% of maximum ionization, I50, for electron beams by the divided difference method" [med. phys. 31, 2068-2074 (2004)]. McEwen M Med Phys; 2004 Nov; 31(11):3158-9; author reply 3160. PubMed ID: 15587668 [No Abstract] [Full Text] [Related]
4. Mean energy, energy-range relationships and depth-scaling factors for clinical electron beams. Ding GX; Rogers DW Med Phys; 1996 Mar; 23(3):361-76. PubMed ID: 8815379 [TBL] [Abstract][Full Text] [Related]
5. Combining tissue-phantom ratios to provide a beam-quality specifier for flattening filter free photon beams. Dalaryd M; Knöös T; Ceberg C Med Phys; 2014 Nov; 41(11):111716. PubMed ID: 25370630 [TBL] [Abstract][Full Text] [Related]
6. Influence of initial electron beam parameters on Monte Carlo calculated absorbed dose distributions for radiotherapy photon beams. Tzedakis A; Damilakis JE; Mazonakis M; Stratakis J; Varveris H; Gourtsoyiannis N Med Phys; 2004 Apr; 31(4):907-13. PubMed ID: 15125009 [TBL] [Abstract][Full Text] [Related]
7. Experimental determination of fluence correction factors at depths beyond dmax for a Farmer type cylindrical ionization chamber in clinical electron beams. Huq MS; Yue N; Suntharalingam N Med Phys; 1997 Oct; 24(10):1609-13. PubMed ID: 9350714 [TBL] [Abstract][Full Text] [Related]
8. Monte Carlo simulation of backscatter from lead for clinical electron beams using EGSnrc. Chow JC; Grigorov GN Med Phys; 2008 Apr; 35(4):1241-50. PubMed ID: 18491516 [TBL] [Abstract][Full Text] [Related]
9. Monte Carlo calculated correction factors for primary standards of air kerma. Rogers DW; Kawrakow I Med Phys; 2003 Apr; 30(4):521-32. PubMed ID: 12722804 [TBL] [Abstract][Full Text] [Related]
10. Brachytherapy dosimetry parameters calculated for a new 103Pd source. Rivard MJ; Melhus CS; Kirk BL Med Phys; 2004 Sep; 31(9):2466-70. PubMed ID: 15487726 [TBL] [Abstract][Full Text] [Related]
11. Calculating percent depth dose with the electron pencil-beam redefinition algorithm. Price MJ; Hogstrom KR; Antolak JA; White RA; Bloch CD; Boyd RA J Appl Clin Med Phys; 2007 Apr; 8(2):61-75. PubMed ID: 17592466 [TBL] [Abstract][Full Text] [Related]
12. Evaluation of a commercial VMC++ Monte Carlo based treatment planning system for electron beams using EGSnrc/BEAMnrc simulations and measurements. Edimo P; Clermont C; Kwato MG; Vynckier S Phys Med; 2009 Sep; 25(3):111-21. PubMed ID: 18722148 [TBL] [Abstract][Full Text] [Related]
13. Variations in energy spectra and water-to-material stopping-power ratios in three-dimensional conformal and intensity-modulated photon fields. Jang SY; Liu HH; Mohan R; Siebers JV Med Phys; 2007 Apr; 34(4):1388-97. PubMed ID: 17500470 [TBL] [Abstract][Full Text] [Related]
14. Stopping-power ratios for electron beams used in total skin electron therapy. Ding GX Med Phys; 2021 Sep; 48(9):5472-5478. PubMed ID: 34287969 [TBL] [Abstract][Full Text] [Related]
15. An accurate energy-range relationship for high-energy electron beams in arbitrary materials. Sorcini BB; Brahme A Phys Med Biol; 1994 May; 39(5):795-811. PubMed ID: 15552086 [TBL] [Abstract][Full Text] [Related]
16. A new approach to electron-beam reference dosimetry. Rogers DW Med Phys; 1998 Mar; 25(3):310-20. PubMed ID: 9547498 [TBL] [Abstract][Full Text] [Related]
17. Comment on "Testing of the analytical anisotropic algorithm for photon dose calculation" [Med. Phys. 33, 4130-4148 (2006)]. Ding GX; Duggan DM; Coffey CW Med Phys; 2007 Aug; 34(8):3414. PubMed ID: 17879803 [No Abstract] [Full Text] [Related]
18. Ion recombination correction for very high dose-per-pulse high-energy electron beams. Di Martino F; Giannelli M; Traino AC; Lazzeri M Med Phys; 2005 Jul; 32(7):2204-10. PubMed ID: 16121574 [TBL] [Abstract][Full Text] [Related]
19. Phantom size in brachytherapy source dosimetric studies. Pérez-Calatayud J; Granero D; Ballester F Med Phys; 2004 Jul; 31(7):2075-81. PubMed ID: 15305460 [TBL] [Abstract][Full Text] [Related]
20. Determination of the relative linear collision stopping power and linear scattering power of electron bolus material. Low DA; Hogstrom KR Phys Med Biol; 1994 Jun; 39(6):1063-8. PubMed ID: 15551581 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]