BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 15588599)

  • 1. An evaluation of the use of passive shimming to improve frontal sensitivity in fMRI.
    Cusack R; Russell B; Cox SM; De Panfilis C; Schwarzbauer C; Ansorge R
    Neuroimage; 2005 Jan; 24(1):82-91. PubMed ID: 15588599
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Positive or negative blips? The effect of phase encoding scheme on susceptibility-induced signal losses in EPI.
    De Panfilis C; Schwarzbauer C
    Neuroimage; 2005 Mar; 25(1):112-21. PubMed ID: 15734348
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optimal EPI parameters for reduction of susceptibility-induced BOLD sensitivity losses: a whole-brain analysis at 3 T and 1.5 T.
    Weiskopf N; Hutton C; Josephs O; Deichmann R
    Neuroimage; 2006 Nov; 33(2):493-504. PubMed ID: 16959495
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Image distortion correction in fMRI: A quantitative evaluation.
    Hutton C; Bork A; Josephs O; Deichmann R; Ashburner J; Turner R
    Neuroimage; 2002 May; 16(1):217-40. PubMed ID: 11969330
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Investigating the benefits of multi-echo EPI for fMRI at 7 T.
    Poser BA; Norris DG
    Neuroimage; 2009 May; 45(4):1162-72. PubMed ID: 19349231
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Computer simulation studies of the effects of dynamic shimming on susceptibility artifacts in EPI at high field.
    Zhao Y; Anderson AW; Gore JC
    J Magn Reson; 2005 Mar; 173(1):10-22. PubMed ID: 15705507
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Compensation of susceptibility-induced BOLD sensitivity losses in echo-planar fMRI imaging.
    Deichmann R; Josephs O; Hutton C; Corfield DR; Turner R
    Neuroimage; 2002 Jan; 15(1):120-35. PubMed ID: 11771980
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Physical and physiological consequences of passive intra-oral shimming.
    Osterbauer RA; Wilson JL; Calvert GA; Jezzard P
    Neuroimage; 2006 Jan; 29(1):245-53. PubMed ID: 16099680
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Susceptibility-matched envelope for the correction of EPI artifacts.
    Neufeld A; Assaf Y; Graif M; Hendler T; Navon G
    Magn Reson Imaging; 2005 Nov; 23(9):947-51. PubMed ID: 16310110
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Spatial sensitivity and temporal response of spin echo and gradient echo bold contrast at 3 T using peak hemodynamic activation time.
    Hulvershorn J; Bloy L; Gualtieri EE; Leigh JS; Elliott MA
    Neuroimage; 2005 Jan; 24(1):216-23. PubMed ID: 15588613
    [TBL] [Abstract][Full Text] [Related]  

  • 11. EPI image reconstruction with correction of distortion and signal losses.
    Liu G; Ogawa S
    J Magn Reson Imaging; 2006 Sep; 24(3):683-9. PubMed ID: 16892198
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Anatomic localization and quantitative analysis of gradient refocused echo-planar fMRI susceptibility artifacts.
    Ojemann JG; Akbudak E; Snyder AZ; McKinstry RC; Raichle ME; Conturo TE
    Neuroimage; 1997 Oct; 6(3):156-67. PubMed ID: 9344820
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Utilization of an intra-oral diamagnetic passive shim in functional MRI of the inferior frontal cortex.
    Wilson JL; Jezzard P
    Magn Reson Med; 2003 Nov; 50(5):1089-94. PubMed ID: 14587020
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Increased BOLD sensitivity in the orbitofrontal cortex using slice-dependent echo times at 3 T.
    Domsch S; Linke J; Heiler PM; Kroll A; Flor H; Wessa M; Schad LR
    Magn Reson Imaging; 2013 Feb; 31(2):201-11. PubMed ID: 22925606
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Combination of BOLD-fMRI and VEP recordings for spin-echo MRI detection of primary magnetic effects caused by neuronal currents.
    Bianciardi M; Di Russo F; Aprile T; Maraviglia B; Hagberg GE
    Magn Reson Imaging; 2004 Dec; 22(10):1429-40. PubMed ID: 15707792
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Application of k-space energy spectrum analysis to susceptibility field mapping and distortion correction in gradient-echo EPI.
    Chen NK; Oshio K; Panych LP
    Neuroimage; 2006 Jun; 31(2):609-22. PubMed ID: 16480898
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Single-shot compensation of image distortions and BOLD contrast optimization using multi-echo EPI for real-time fMRI.
    Weiskopf N; Klose U; Birbaumer N; Mathiak K
    Neuroimage; 2005 Feb; 24(4):1068-79. PubMed ID: 15670684
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The cost of parallel imaging in functional MRI of the human brain.
    Lütcke H; Merboldt KD; Frahm J
    Magn Reson Imaging; 2006 Jan; 24(1):1-5. PubMed ID: 16410172
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Combined passive and active shimming for in vivo MR spectroscopy at high magnetic fields.
    Juchem C; Muller-Bierl B; Schick F; Logothetis NK; Pfeuffer J
    J Magn Reson; 2006 Dec; 183(2):278-89. PubMed ID: 17011219
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Spinal cord functional MRI at 3 T: gradient echo echo-planar imaging versus turbo spin echo.
    Bouwman CJ; Wilmink JT; Mess WH; Backes WH
    Neuroimage; 2008 Nov; 43(2):288-96. PubMed ID: 18706507
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.