These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
180 related articles for article (PubMed ID: 1559360)
1. Ventilation/perfusion indices do not correlate with the difference between oxygen consumption measured by the Fick principle and metabolic monitoring systems in critically ill patients. Myburgh JA; Webb RK; Worthley LI Crit Care Med; 1992 Apr; 20(4):479-82. PubMed ID: 1559360 [TBL] [Abstract][Full Text] [Related]
2. Real-time gas-exchange measurement of oxygen consumption in neonates and infants after cardiac surgery. Chang AC; Kulik TJ; Hickey PR; Wessel DL Crit Care Med; 1993 Sep; 21(9):1369-75. PubMed ID: 8370302 [TBL] [Abstract][Full Text] [Related]
3. [Inverse fick's principle in comparison to measurements of oxygen consumption in respiratory gases. Does intrapulmonary oxygen uptake account for differences shown by different system methods?]. Weyland A; Weyland W; Sydow M; Weyland C; Kettler D Anaesthesist; 1994 Oct; 43(10):658-66. PubMed ID: 7818047 [TBL] [Abstract][Full Text] [Related]
4. Oxygen consumption after cardiopulmonary bypass--implications of different measuring methods. Oudemans-van Straaten HM; Scheffer GJ; Eysman L; Wildevuur CR Intensive Care Med; 1993; 19(2):105-10. PubMed ID: 8486864 [TBL] [Abstract][Full Text] [Related]
5. Derived oxygen saturations are not clinically useful for the calculation of oxygen consumption. Myburgh JA Anaesth Intensive Care; 1992 Nov; 20(4):460-3. PubMed ID: 1463173 [TBL] [Abstract][Full Text] [Related]
7. Measuring oxygen uptake and carbon dioxide production in critically ill patients using a standard blood gas analyzer. Zenger M; Brenner M; Hua P; Haruno M; Wilson AF Crit Care Med; 1994 May; 22(5):783-8. PubMed ID: 8181286 [TBL] [Abstract][Full Text] [Related]
8. Respiratory deadspace measurements in neonates during extracorporeal membrane oxygenation. Arnold JH; Thompson JE; Benjamin PK Crit Care Med; 1993 Dec; 21(12):1895-900. PubMed ID: 8252895 [TBL] [Abstract][Full Text] [Related]
10. Correlation between oxygen consumption calculated using Fick's method and measured with indirect calorimetry in critically ill patients. Marson F; Auxiliadora Martins M; Coletto FA; Campos AD; Basile-Filho A Arq Bras Cardiol; 2004 Jan; 82(1):77-81, 72-6. PubMed ID: 14978596 [TBL] [Abstract][Full Text] [Related]
11. Calculated versus measured oxygen consumption during and after cardiac surgery. Is it possible to estimate lung oxygen consumption? Keinänen O; Takala J Acta Anaesthesiol Scand; 1997 Aug; 41(7):803-9. PubMed ID: 9265920 [TBL] [Abstract][Full Text] [Related]
12. Predicting dead space ventilation in critically ill patients using clinically available data. Frankenfield DC; Alam S; Bekteshi E; Vender RL Crit Care Med; 2010 Jan; 38(1):288-91. PubMed ID: 19789453 [TBL] [Abstract][Full Text] [Related]
13. Energy expenditure and gas exchange measurements in postoperative patients: thermodilution versus indirect calorimetry. Brandi LS; Grana M; Mazzanti T; Giunta F; Natali A; Ferrannini E Crit Care Med; 1992 Sep; 20(9):1273-83. PubMed ID: 1521442 [TBL] [Abstract][Full Text] [Related]
14. Use of continuous noninvasive measurement of oxygen consumption in patients with adult respiratory distress syndrome following shock of various etiologies. Hankeln KB; Gronemeyer R; Held A; Böhmert F Crit Care Med; 1991 May; 19(5):642-9. PubMed ID: 2026026 [TBL] [Abstract][Full Text] [Related]
15. Oxygen Fick and modified carbon dioxide Fick cardiac outputs. Mahutte CK; Jaffe MB; Chen PA; Sasse SA; Wong DH; Sassoon CS Crit Care Med; 1994 Jan; 22(1):86-95. PubMed ID: 8124981 [TBL] [Abstract][Full Text] [Related]
16. Evaluation of oxygen uptake and delivery in critically ill patients: a statistical reappraisal. Hanique G; Dugernier T; Laterre PF; Roeseler J; Dougnac A; Reynaert MS Intensive Care Med; 1994; 20(1):19-26. PubMed ID: 8163753 [TBL] [Abstract][Full Text] [Related]
17. A comparison between the Fick method and indirect calorimetry for determining oxygen consumption in patients with fulminant hepatic failure. Walsh TS; Hopton P; Lee A Crit Care Med; 1998 Jul; 26(7):1200-7. PubMed ID: 9671369 [TBL] [Abstract][Full Text] [Related]
18. Spirometric versus Fick-derived oxygen consumption: which method is better? Thrush DN Crit Care Med; 1996 Jan; 24(1):91-5. PubMed ID: 8565545 [TBL] [Abstract][Full Text] [Related]
19. The relation of near-infrared spectroscopy with changes in peripheral circulation in critically ill patients. Lima A; van Bommel J; Sikorska K; van Genderen M; Klijn E; Lesaffre E; Ince C; Bakker J Crit Care Med; 2011 Jul; 39(7):1649-54. PubMed ID: 21685739 [TBL] [Abstract][Full Text] [Related]
20. Effects of ventilator resetting on indirect calorimetry measurement in the critically ill surgical patient. Brandi LS; Bertolini R; Santini L; Cavani S Crit Care Med; 1999 Mar; 27(3):531-9. PubMed ID: 10199532 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]