These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

419 related articles for article (PubMed ID: 15603785)

  • 21. The effect of post-sintering heat treatments on the fatigue properties of porous coated Ti-6Al-4V alloy.
    Cook SD; Thongpreda N; Anderson RC; Haddad RJ
    J Biomed Mater Res; 1988 Apr; 22(4):287-302. PubMed ID: 3372550
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The corrosion behaviour of Ti-6Al-4V, Ti-6Al-7Nb and Ti-13Nb-13Zr in protein solutions.
    Khan MA; Williams RL; Williams DF
    Biomaterials; 1999 Apr; 20(7):631-7. PubMed ID: 10208405
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Titanium alloys: in vitro biological analyzes on biofilm formation, biocompatibility, cell differentiation to induce bone formation, and immunological response.
    Mello DCR; de Oliveira JR; Cairo CAA; Ramos LSB; Vegian MRDC; de Vasconcellos LGO; de Oliveira FE; de Oliveira LD; de Vasconcellos LMR
    J Mater Sci Mater Med; 2019 Sep; 30(9):108. PubMed ID: 31535222
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Fatigue properties of carbon- and porous-coated Ti-6Al-4V alloy.
    Cook SD; Georgette FS; Skinner HB; Haddad RJ
    J Biomed Mater Res; 1984; 18(5):497-512. PubMed ID: 6736080
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Corrosion-fatigue life of commercially pure titanium and Ti-6Al-4V alloys in different storage environments.
    Zavanelli RA; Pessanha Henriques GE; Ferreira I; De Almeida Rollo JM
    J Prosthet Dent; 2000 Sep; 84(3):274-9. PubMed ID: 11005899
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Fracture analysis of cast pure Ti and Ti-6Al-4V alloy for dental use.
    Kim KH; Choi MY; Kishi T
    Biomed Mater Eng; 1997; 7(4):271-6. PubMed ID: 9408579
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Mechanical Properties and Residual Stress Measurements of Grade IV Titanium and Ti-6Al-4V and Ti-13Nb-13Zr Titanium Alloys after Laser Treatment.
    Jażdżewska M; Kwidzińska DB; Seyda W; Fydrych D; Zieliński A
    Materials (Basel); 2021 Oct; 14(21):. PubMed ID: 34771847
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Nanocomposite hydroxyapatite formation on a Ti-13Nb-13Zr alloy exposed in a MEM cell culture medium and the effect of H2O2 addition.
    Baker MA; Assis SL; Higa OZ; Costa I
    Acta Biomater; 2009 Jan; 5(1):63-75. PubMed ID: 18815081
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Over-refractory casting technique as an alternative to one-piece multi-unit fixed partial denture frameworks.
    de Oliveira Correa G; Henriques GE; Mesquita MF; Sobrinho LC
    J Prosthet Dent; 2006 Mar; 95(3):243-8. PubMed ID: 16543023
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparative study on torsional strength, ductility and fracture characteristics of laser-welded alpha+beta Ti-6Al-7Nb alloy, CP Titanium and Co-Cr alloy dental castings.
    Srimaneepong V; Yoneyama T; Kobayashi E; Doi H; Hanawa T
    Dent Mater; 2008 Jun; 24(6):839-45. PubMed ID: 18054380
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Mechanical performance of the new posterior spinal implant: effect of materials, connecting plate, and pedicle screw design.
    Chen PQ; Lin SJ; Wu SS; So H
    Spine (Phila Pa 1976); 2003 May; 28(9):881-6; discussion 887. PubMed ID: 12942002
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Mechanical properties of the binary titanium-zirconium alloys and their potential for biomedical materials.
    Kobayashi E; Matsumoto S; Doi H; Yoneyama T; Hamanaka H
    J Biomed Mater Res; 1995 Aug; 29(8):943-50. PubMed ID: 7593037
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Influence of heat treatment and oxygen doping on the mechanical properties and biocompatibility of titanium-niobium binary alloys.
    da Silva LM; Claro AP; Donato TA; Arana-Chavez VE; Moraes JC; Buzalaf MA; Grandini CR
    Artif Organs; 2011 May; 35(5):516-21. PubMed ID: 21595721
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Acoustic emission during fatigue of porous-coated Ti-6Al-4V implant alloy.
    Kohn DH; Ducheyne P; Awerbuch J
    J Biomed Mater Res; 1992 Jan; 26(1):19-38. PubMed ID: 1577833
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Electrochemical studies of the corrosion behaviour of titanium and the Ti-6Al-4V alloy using electrochemical impedance spectroscopy.
    Grosgogeat B; Boinet M; Dalard F; Lissac M
    Biomed Mater Eng; 2004; 14(3):323-31. PubMed ID: 15299244
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Surface elastic properties of Ti alloys modified for medical implants: a force spectroscopy study.
    Munuera C; Matzelle TR; Kruse N; López MF; Gutiérrez A; Jiménez JA; Ocal C
    Acta Biomater; 2007 Jan; 3(1):113-9. PubMed ID: 17070123
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Selection and evaluation of blood- and tribologically compatible journal bearing materials.
    Murray SF; Calabrese SJ; Malanoski SB; Golding LR; Smith WA; Hamby M
    ASAIO J; 1997; 43(5):M603-8. PubMed ID: 9360116
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Novel production method and in-vitro cell compatibility of porous Ti-6Al-4V alloy disk for hard tissue engineering.
    Bhattarai SR; Khalil KA; Dewidar M; Hwang PH; Yi HK; Kim HY
    J Biomed Mater Res A; 2008 Aug; 86(2):289-99. PubMed ID: 17957720
    [TBL] [Abstract][Full Text] [Related]  

  • 39. In vitro apatite formation on chemically treated (P/M) Ti-13Nb-13Zr.
    Müller FA; Bottino MC; Müller L; Henriques VA; Lohbauer U; Bressiani AH; Bressiani JC
    Dent Mater; 2008 Jan; 24(1):50-6. PubMed ID: 17442387
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Superplastic forming of titanium alloy denture base].
    Okuno O; Nakano T; Hamanaka H; Miura I; Ito M; Ai M; Okada M
    Shika Zairyo Kikai; 1989 Mar; 8(2):129-36. PubMed ID: 2603084
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 21.