173 related articles for article (PubMed ID: 15604825)
1. Improving the dynamic response of a mediator-less microbial fuel cell as a biochemical oxygen demand (BOD) sensor.
Moon H; Chang IS; Kang KH; Jang JK; Kim BH
Biotechnol Lett; 2004 Nov; 26(22):1717-21. PubMed ID: 15604825
[TBL] [Abstract][Full Text] [Related]
2. A microbial fuel cell with improved cathode reaction as a low biochemical oxygen demand sensor.
Kang KH; Jang JK; Pham TH; Moon H; Chang IS; Kim BH
Biotechnol Lett; 2003 Aug; 25(16):1357-61. PubMed ID: 14514065
[TBL] [Abstract][Full Text] [Related]
3. Improvement of a microbial fuel cell performance as a BOD sensor using respiratory inhibitors.
Chang IS; Moon H; Jang JK; Kim BH
Biosens Bioelectron; 2005 Mar; 20(9):1856-9. PubMed ID: 15681205
[TBL] [Abstract][Full Text] [Related]
4. Continuous determination of biochemical oxygen demand using microbial fuel cell type biosensor.
Chang IS; Jang JK; Gil GC; Kim M; Kim HJ; Cho BW; Kim BH
Biosens Bioelectron; 2004 Jan; 19(6):607-13. PubMed ID: 14683644
[TBL] [Abstract][Full Text] [Related]
5. Short-term BOD (BODst) as a parameter for on-line monitoring of biological treatment process. Part I. A novel design of BOD biosensor for easy renewal of bio-receptor.
Liu J; Olsson G; Mattiasson B
Biosens Bioelectron; 2004 Oct; 20(3):562-70. PubMed ID: 15494240
[TBL] [Abstract][Full Text] [Related]
6. Micromachined oxygen gas sensors for microscopic energy consumption measurement systems.
Wu CC; Lee GB; Chen MH; Luo CH
J Med Eng Technol; 2005; 29(6):278-87. PubMed ID: 16287677
[TBL] [Abstract][Full Text] [Related]
7. A single-chamber microbial fuel cell as a biosensor for wastewaters.
Di Lorenzo M; Curtis TP; Head IM; Scott K
Water Res; 2009 Jul; 43(13):3145-54. PubMed ID: 19482326
[TBL] [Abstract][Full Text] [Related]
8. Membrane-electrode assembly enhances performance of a microbial fuel cell type biological oxygen demand sensor.
Kim M; Hyun MS; Gadd GM; Kim GT; Lee SJ; Kim HJ
Environ Technol; 2009 Apr; 30(4):329-36. PubMed ID: 19492544
[TBL] [Abstract][Full Text] [Related]
9. Detection and identification of bacteria using antibiotic susceptibility and a multi-array electrochemical sensor with pattern recognition.
Karasinski J; White L; Zhang Y; Wang E; Andreescu S; Sadik OA; Lavine BK; Vora M
Biosens Bioelectron; 2007 May; 22(11):2643-9. PubMed ID: 17169547
[TBL] [Abstract][Full Text] [Related]
10. Operational parameters affecting the performannce of a mediator-less microbial fuel cell.
Gil GC; Chang IS; Kim BH; Kim M; Jang JK; Park HS; Kim HJ
Biosens Bioelectron; 2003 Apr; 18(4):327-34. PubMed ID: 12604249
[TBL] [Abstract][Full Text] [Related]
11. A novel bioelectrochemical BOD sensor operating with voltage input.
Modin O; Wilén BM
Water Res; 2012 Nov; 46(18):6113-20. PubMed ID: 23021520
[TBL] [Abstract][Full Text] [Related]
12. Microbial fuel cell biosensor for in situ assessment of microbial activity.
Tront JM; Fortner JD; Plötze M; Hughes JB; Puzrin AM
Biosens Bioelectron; 2008 Dec; 24(4):586-90. PubMed ID: 18621521
[TBL] [Abstract][Full Text] [Related]
13. Immobilized multi-species based biosensor for rapid biochemical oxygen demand measurement.
Liu C; Ma C; Yu D; Jia J; Liu L; Zhang B; Dong S
Biosens Bioelectron; 2011 Jan; 26(5):2074-9. PubMed ID: 20889329
[TBL] [Abstract][Full Text] [Related]
14. Application of a biosensor for monitoring of ethanol.
Wen G; Zhang Y; Shuang S; Dong C; Choi MM
Biosens Bioelectron; 2007 Aug; 23(1):121-9. PubMed ID: 17561389
[TBL] [Abstract][Full Text] [Related]
15. Techniques for the study and development of microbial fuel cells: an electrochemical perspective.
Zhao F; Slade RC; Varcoe JR
Chem Soc Rev; 2009 Jul; 38(7):1926-39. PubMed ID: 19551173
[TBL] [Abstract][Full Text] [Related]
16. Short-term BOD (BODst) as a parameter for on-line monitoring of biological treatment process; Part II: instrumentation of integrated flow injection analysis (FIA) system for BODst estimation.
Liu J; Olsson G; Mattiasson B
Biosens Bioelectron; 2004 Oct; 20(3):571-8. PubMed ID: 15494241
[TBL] [Abstract][Full Text] [Related]
17. A biosensor for the analysis of acetonitrile.
Håkansson K; Mattiasson B
Biosens Bioelectron; 2004 Feb; 19(7):721-6. PubMed ID: 14709390
[TBL] [Abstract][Full Text] [Related]
18. Co-immobilized microbial biosensor for BOD estimation based on sol-gel derived composite material.
Jia J; Tang M; Chen X; Qi L; Dong S
Biosens Bioelectron; 2003 Aug; 18(8):1023-9. PubMed ID: 12782465
[TBL] [Abstract][Full Text] [Related]
19. Development of mediated BOD biosensor system of flow injection mode for shochu distillery wastewater.
Oota S; Hatae Y; Amada K; Koya H; Kawakami M
Biosens Bioelectron; 2010 Sep; 26(1):262-6. PubMed ID: 20638832
[TBL] [Abstract][Full Text] [Related]
20. Development of an automated water toxicity biosensor using Thiobacillus ferrooxidans for monitoring cyanides in natural water for a water filtering plant.
Okochi M; Mima K; Miyata M; Shinozaki Y; Haraguchi S; Fujisawa M; Kaneko M; Masukata T; Matsunaga T
Biotechnol Bioeng; 2004 Sep; 87(7):905-11. PubMed ID: 15334417
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]