These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 15613024)

  • 1. Lupus anticoagulant testing using plasma spiked with monoclonal antibodies: performance in the UK NEQAS proficiency testing programme.
    Jennings I; Mackie I; Arnout J; Preston FE;
    J Thromb Haemost; 2004 Dec; 2(12):2178-84. PubMed ID: 15613024
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Lupus anticoagulant testing in Europe: an analysis of results from the first European Concerted Action on Thrombophilia (ECAT) survey using plasmas spiked with monoclonal antibodies against human beta2-glycoprotein I.
    Arnout J; Meijer P; Vermylen J
    Thromb Haemost; 1999 Jun; 81(6):929-34. PubMed ID: 10404770
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Potentially clinically important inaccuracies in testing for the lupus anticoagulant: an analysis of results from three surveys of the UK National External Quality Assessment Scheme (NEQAS) for Blood Coagulation.
    Jennings I; Kitchen S; Woods TA; Preston FE; Greaves M
    Thromb Haemost; 1997 May; 77(5):934-7. PubMed ID: 9184405
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Lupus anticoagulant testing: improvements in performance in a UK NEQAS proficiency testing exercise after dissemination of national guidelines on laboratory methods.
    Jennings I; Greaves M; Mackie IJ; Kitchen S; Woods TA; Preston FE;
    Br J Haematol; 2002 Nov; 119(2):364-9. PubMed ID: 12406070
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Methods for subtyping lupus anticoagulants.
    Exner T
    Lupus; 1998; 7 Suppl 2():S103-6. PubMed ID: 9814684
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quantification of lupus anticoagulants in clinical samples using anti-beta2GP1 and anti-prothrombin monoclonal antibodies.
    Le Querrec A; Arnout J; Arnoux D; Borg JY; Caron C; Darnige L; Delahousse B; Reber G; Sié P
    Thromb Haemost; 2001 Aug; 86(2):584-9. PubMed ID: 11522007
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A two-step coagulation test to identify antibeta-glycoprotein I lupus anticoagulants.
    Pengo V; Biasiolo A; Pegoraro C; Iliceto S
    J Thromb Haemost; 2004 May; 2(5):702-7. PubMed ID: 15099274
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Variability of cut-off values for the detection of lupus anticoagulants: results of an international multicenter multiplatform study.
    Tripodi A; Chantarangkul V; Cini M; Devreese K; Dlott JS; Giacomello R; Gray E; Legnani C; Martinuzzo ME; Pradella P; Siegemund A; Subramanian S; Suchon P; Testa S
    J Thromb Haemost; 2017 Jun; 15(6):1180-1190. PubMed ID: 28316135
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Lupus-anticoagulant testing at NOAC trough levels.
    Ratzinger F; Lang M; Belik S; Jilma-Stohlawetz P; Schmetterer KG; Haslacher H; Perkmann T; Quehenberger P
    Thromb Haemost; 2016 Aug; 116(2):235-40. PubMed ID: 27075441
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Kaolin clotting time and dilute Russell's viper venom time distinguish between prothrombin-dependent and beta 2-glycoprotein I-dependent antiphospholipid antibodies.
    Galli M; Finazzi G; Bevers EM; Barbui T
    Blood; 1995 Jul; 86(2):617-23. PubMed ID: 7605991
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Coagulation tests and anti-phospholipid antibodies in patients positive for lupus anticoagulant.
    Sakakura M; Wada H; Watanabe R; Mamamuro M; Okugawa Y; Nakasaki T; Nakase T; Wakita Y; Minamikawa K; Mori Y; Nshikawa M; Shiku H
    Clin Appl Thromb Hemost; 2000 Jul; 6(3):144-50. PubMed ID: 10898274
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Lupus anticoagulant (LA) testing: performance of clinical laboratories assessed by a national survey using lyophilized affinity-purified immunoglobulin with LA activity.
    Tripodi A; Biasiolo A; Chantarangkul V; Pengo V
    Clin Chem; 2003 Oct; 49(10):1608-14. PubMed ID: 14500585
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Monoclonal antibodies against beta-2-glycoprotein I: use as reference material for lupus anticoagulant tests.
    Arnout J; Vanrusselt M; Wittevrongel C; Vermylen J
    Thromb Haemost; 1998 May; 79(5):955-8. PubMed ID: 9609228
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effect of DOAC-Stop on lupus anticoagulant testing in plasma samples of venous thromboembolism patients receiving direct oral anticoagulants.
    Ząbczyk M; Kopytek M; Natorska J; Undas A
    Clin Chem Lab Med; 2019 Aug; 57(9):1374-1381. PubMed ID: 30763261
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Mixing test specific cut-off is more sensitive at detecting lupus anticoagulants than index of circulating anticoagulant.
    Moore GW; Culhane AP; Daw CR; Noronha CP; Kumano O
    Thromb Res; 2016 Mar; 139():98-101. PubMed ID: 26916303
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The role of beta 2-glycoprotein I-dependent lupus anticoagulants in the pathogenesis of the antiphospholipid syndrome.
    Arnout J
    Verh K Acad Geneeskd Belg; 2000; 62(5):353-72. PubMed ID: 11144685
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of test methods for the lupus anticoagulant: international survey on lupus anticoagulants-I (ISLA-1).
    Exner T; Triplett DA; Taberner DA; Howard MA; Harris EN
    Thromb Haemost; 1990 Nov; 64(3):478-84. PubMed ID: 2128977
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Laboratory identification of lupus anticoagulants: results of the Second International Workshop for Identification of Lupus Anticoagulants. On behalf of the Subcommittee on Lupus Anticoagulants/Antiphospholipid Antibodies of the ISTH.
    Brandt JT; Barna LK; Triplett DA
    Thromb Haemost; 1995 Dec; 74(6):1597-603. PubMed ID: 8772243
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Laboratory diagnosis of lupus anticoagulants for patients on oral anticoagulant treatment. Performance of dilute Russell viper venom test and silica clotting time in comparison with Staclot LA.
    Tripodi A; Chantarangkul V; Clerici M; Mannucci PM
    Thromb Haemost; 2002 Oct; 88(4):583-6. PubMed ID: 12362227
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Applying index of circulating anticoagulant to mixing tests with lupus anticoagulant screen and confirm reagents can distinguish with high specificity between lupus anticoagulants and direct factor Xa inhibitors.
    Kumano O; Amiral J; Dunois C; Peyrafitte M; Moore GW
    Int J Lab Hematol; 2021 Aug; 43(4):771-778. PubMed ID: 33974363
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.