154 related articles for article (PubMed ID: 1561349)
1. Intracranial venous system in newborns treated with extracorporeal membrane oxygenation: Doppler US evaluation after ligation of the right jugular vein.
Taylor GA; Walker LK
Radiology; 1992 May; 183(2):453-6. PubMed ID: 1561349
[TBL] [Abstract][Full Text] [Related]
2. The effects of venous occlusion on cerebral blood flow characteristics during ECMO.
Weber TR; Kountzman B
J Pediatr Surg; 1996 Aug; 31(8):1124-7. PubMed ID: 8863247
[TBL] [Abstract][Full Text] [Related]
3. Intracranial venous system in the newborn: evaluation of normal anatomy and flow characteristics with color Doppler US.
Taylor GA
Radiology; 1992 May; 183(2):449-52. PubMed ID: 1561348
[TBL] [Abstract][Full Text] [Related]
4. Jugular ligation does not increase intracranial pressure but does increase bihemispheric cerebral blood flow and metabolism.
Chai PJ; Skaryak LA; Ungerleider RM; Greeley WJ; Kern FH; Schulman SR; Hansell DR; Auten RL; Mahaffey SF; Meliones JN
Crit Care Med; 1995 Nov; 23(11):1864-71. PubMed ID: 7587263
[TBL] [Abstract][Full Text] [Related]
5. The intracranial venous system in infants: normal and abnormal findings on duplex and color Doppler sonography.
Dean LM; Taylor GA
AJR Am J Roentgenol; 1995 Jan; 164(1):151-6. PubMed ID: 7998529
[TBL] [Abstract][Full Text] [Related]
6. Circle of Willis blood velocity and flow direction after common carotid artery ligation for neonatal extracorporeal membrane oxygenation.
Raju TN; Kim SY; Meller JL; Srinivasan G; Ghai V; Reyes H
Pediatrics; 1989 Mar; 83(3):343-7. PubMed ID: 2645565
[TBL] [Abstract][Full Text] [Related]
7. Cerebral blood flow and oxygenation during venoarterial and venovenous extracorporeal membrane oxygenation in the newborn lamb.
Hunter CJ; Blood AB; Bishai JM; Hickerson AD; Wall DD; Peverini RL; Power GG; Hopper AO
Pediatr Crit Care Med; 2004 Sep; 5(5):475-81. PubMed ID: 15329165
[TBL] [Abstract][Full Text] [Related]
8. Cephalic jugular venous blood gas measurement during neonatal venoarterial extracorporeal membrane oxygenation.
O'Connor TA; Haney BM; Shaffer SG; Grist GE
J Extra Corpor Technol; 1993; 24(4):113-5. PubMed ID: 10148322
[TBL] [Abstract][Full Text] [Related]
9. Oxygenation and hemodynamics in left and right cerebral hemispheres during induction of veno-arterial extracorporeal membrane oxygenation.
Van Heijst A; Liem D; Hopman J; Van Der Staak F; Sengers R
J Pediatr; 2004 Feb; 144(2):223-8. PubMed ID: 14760266
[TBL] [Abstract][Full Text] [Related]
10. Right common carotid artery ligation for extracorporeal membrane oxygenation: cerebral blood flow velocity measurement with Doppler duplex US.
Matsumoto JS; Babcock DS; Brody AS; Weiss RG; Ryckman FG; Hiyama D
Radiology; 1990 Jun; 175(3):757-60. PubMed ID: 2188299
[TBL] [Abstract][Full Text] [Related]
11. Comparison of venoarterial versus venovenous access in the cerebral circulation of newborns undergoing extracorporeal membrane oxygenation.
Fukuda S; Aoyama M; Yamada Y; Saitoh N; Honjoh T; Hasegawa T; Futamura M; Katoh J; Niimi N; Tanaka S; Nagaya M
Pediatr Surg Int; 1999; 15(2):78-84. PubMed ID: 10079335
[TBL] [Abstract][Full Text] [Related]
12. Reverse blood flow in cervicofacial veins after venous ligations: Potential implications in microsurgery.
Nokovitch L; Peyrachon B; Chaux-Bodard AG; Poupart M; Roux PE; Devauchelle B; Deneuve S
J Plast Reconstr Aesthet Surg; 2021 Sep; 74(9):2042-2049. PubMed ID: 33455872
[TBL] [Abstract][Full Text] [Related]
13. Pilot study of intracranial venous physiology in craniosynostosis.
Cornelissen MJ; de Goederen R; Doerga P; Cuperus I; van Veelen ML; Lequin M; Govaert P; Mathijssen IMJ; Dudink J; Tasker RC
J Neurosurg Pediatr; 2018 Jun; 21(6):626-631. PubMed ID: 29624144
[TBL] [Abstract][Full Text] [Related]
14. Right common carotid artery reconstruction in neonates after extracorporeal membrane oxygenation: color Doppler imaging.
DeAngelis GA; Mitchell DG; Merton DA; Wolfson PJ; Desai HJ; Desai SA; Graziani LJ
Radiology; 1992 Feb; 182(2):521-5. PubMed ID: 1732973
[TBL] [Abstract][Full Text] [Related]
15. Proximal and distal cannulation of the internal jugular vein for ECMO in a primate.
Kitagawa H; Mccomb G; Ford E; Atkinson JB
J Pediatr Surg; 1992 Sep; 27(9):1189-91. PubMed ID: 1432526
[TBL] [Abstract][Full Text] [Related]
16. Use of umbilical vessels for neonatal ECMO cannulation: possibilities and precautions.
Cornish JD; Dudell GG; Evans ML; Sweet LD; Moulton SL
ASAIO Trans; 1991; 37(4):545-8. PubMed ID: 1768485
[TBL] [Abstract][Full Text] [Related]
17. [Trans-fontanellar Doppler sonography of the intracranial veins in infants--part I--Normal values].
Deeg KH; Lode HM
Ultraschall Med; 2005 Dec; 26(6):507-17. PubMed ID: 16453222
[TBL] [Abstract][Full Text] [Related]
18. Changes in superior sagittal sinus blood velocities due to postural alterations and pressure on the head of the newborn infant.
Cowan F; Thoresen M
Pediatrics; 1985 Jun; 75(6):1038-47. PubMed ID: 3889817
[TBL] [Abstract][Full Text] [Related]
19. Extracorporeal membrane oxygenation in infants: angiographic and parenchymal evaluation of the brain with MR imaging.
Lewin JS; Masaryk TJ; Modic MT; Ross JS; Stork EK; Wiznitzer M
Radiology; 1989 Nov; 173(2):361-5. PubMed ID: 2798869
[TBL] [Abstract][Full Text] [Related]
20. Collapsibility of the internal jugular veins in the lateral decubitus body position: A potential protective role of the cerebral venous outflow against neurodegeneration.
Simka M; Czaja J; Kowalczyk D
Med Hypotheses; 2019 Dec; 133():109397. PubMed ID: 31526984
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]