These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

169 related articles for article (PubMed ID: 1561468)

  • 21. [Rupture and fragmentation of a polyethylene terephthalate balloon catheter in a calcified coronary artery stenosis].
    Schräder R; Krause E; Blum U; Kober G
    Z Kardiol; 1990 Mar; 79(3):199-202. PubMed ID: 2141209
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Successful closure of coronary artery perforation using non-conventional embolic material.
    Trehan VK; Mulkhopadhyay S; Yusuf J; Rangasetty UC; Arora R
    Indian Heart J; 2005; 57(2):170-1. PubMed ID: 16013360
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Surgical management of entrapped percutaneous transluminal coronary angioplasty hardware.
    Chang TM; Pellegrini D; Ostrovsky A; Marrangoni AG
    Tex Heart Inst J; 2002; 29(4):329-32. PubMed ID: 12484620
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The fracture, dislodgement and retrieval of a probe III balloon-on-a-wire catheter.
    Hwang MH; Hsieh AA; Silverman P; Loeb HS
    J Invasive Cardiol; 1994 Jun; 6(5):154-6. PubMed ID: 10155063
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [A rare case of coronary artery perforation by a PTCA guide wire complicating with postinfarction cardiac rupture after thrombolytic therapy].
    Ogino H; Miki S; Ueda Y; Tahata T; Morioka K; Sakai T
    Nihon Kyobu Geka Gakkai Zasshi; 1995 Aug; 43(8):1151-4. PubMed ID: 7594850
    [TBL] [Abstract][Full Text] [Related]  

  • 26. An unusual case of guide wire fracture during percutaneous transluminal coronary angioplasty.
    Vrolix M; Vanhaecke J; Piessens J; De Geest H
    Cathet Cardiovasc Diagn; 1988; 15(2):99-102. PubMed ID: 2972384
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Balloon entrapment in a coronary artery: potential serious complications of balloon rupture.
    Colombo A; Skinner JM
    Cathet Cardiovasc Diagn; 1990 Jan; 19(1):23-5. PubMed ID: 2306760
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Guidewire fracture: an unusual complication of percutaneous transluminal coronary angioplasty.
    Stellin G; Ramondo A; Bortolotti U
    Int J Cardiol; 1987 Dec; 17(3):339-42. PubMed ID: 2960627
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Proximal balloon deflation technique: a novel method to retrieve retained or entrapped equipment from the coronary system.
    Ashikaga T; Inagaki H; Satoh Y; Isobe M
    Cardiovasc Revasc Med; 2012; 13(4):253-5. PubMed ID: 22591764
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Thrombotic occlusion of the coronary artery associated with accidental detachment of undeployed Palmaz-Schatz stent.
    Shiojima I; Ikari Y; Abe J; Ishizaka N; Maemura K; Kurihara H; Isshiki TA; Suma H; Saeki H; Hara K; Tamura T; Yamaguchi T
    Cathet Cardiovasc Diagn; 1996 Aug; 38(4):360-2. PubMed ID: 8853142
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Early experience with low speed rotational angioplasty.
    Anderson MH; Ward DE
    Br Heart J; 1991 Aug; 66(2):130-3. PubMed ID: 1883663
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Acute success rates of percutaneous transluminal coronary angioplasty in the treatment of chronic complete occlusions with use of the 0.014 magnum Meier wire.
    Mauser M
    Angiology; 2000 Oct; 51(10):849-54. PubMed ID: 11108329
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Broken guidewire fragment in the radio-brachial artery during transradial sheath placement: percutaneous retrieval via femoral approach.
    Kim JY; Yoon J; Jung HS; Kim WJ; Yoo BS; Lee SH; Choi KH
    Yonsei Med J; 2005 Feb; 46(1):166-8. PubMed ID: 15744822
    [TBL] [Abstract][Full Text] [Related]  

  • 34. An unusual case of guide wire fractured during primary percutaneous coronary intervention, and two year follow-up.
    Kaplan S; Kaplan ST; Kutlu M
    Kardiol Pol; 2010 Nov; 68(11):1291-3. PubMed ID: 21108216
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Pressure-wire guided balloon angioplasty in allograft coronary vasculopathy.
    Casella G; Rieber J; Mudra H; Klauss V
    J Heart Lung Transplant; 1999 Nov; 18(11):1143-6. PubMed ID: 10598740
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Entrapment of broken guidewire in the left main coronary artery during percutaneous transluminal coronary angioplasty.
    Sethi GK; Ferguson TB; Miller G; Scott SM
    Ann Thorac Surg; 1989 Mar; 47(3):455-7. PubMed ID: 2522760
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Successful percutaneous removal of retained probe balloon wire during coronary angioplasty.
    Yeon EB; Cemaletin NS; Moses JW; McCrossan J
    Am Heart J; 1990 May; 119(5):1201-5. PubMed ID: 2330879
    [No Abstract]   [Full Text] [Related]  

  • 38. Coronary artery dissection caused by angioplasty balloon rupture.
    Rothschild R; Voda J
    Cathet Cardiovasc Diagn; 1990 Jan; 19(1):26-9. PubMed ID: 2306761
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Circumferential rupture and entrapment of a balloon-on-a-wire device during coronary angioplasty.
    Nukta E; Meier B; Urban P; Muller T
    Cathet Cardiovasc Diagn; 1990 Jun; 20(2):123-5. PubMed ID: 2354512
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Complication in rotation angioplasty: removal of an intracoronary metal ring (roentgen marker) using a balloon catheter].
    Leisch F; Kerschner K
    Z Kardiol; 1990 Sep; 79(9):663-5. PubMed ID: 2238778
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.