175 related articles for article (PubMed ID: 15616092)
1. Conventional tracheal tubes for intubation through the intubating laryngeal mask airway.
Kundra P; Sujata N; Ravishankar M
Anesth Analg; 2005 Jan; 100(1):284-288. PubMed ID: 15616092
[TBL] [Abstract][Full Text] [Related]
2. A comparison of conventional endotracheal tube with silicone wire-reinforced tracheal tube for intubation through intubating laryngeal mask airway.
Shah VR; Bhosale GP; Mehta T; Parikh GP
Saudi J Anaesth; 2014 Apr; 8(2):183-7. PubMed ID: 24843329
[TBL] [Abstract][Full Text] [Related]
3. Endotracheal intubation through the intubating laryngeal mask airway (LMA-Fastrach™): A randomized study of LMA- Fastrach™ wire-reinforced silicone endotracheal tube versus conventional polyvinyl chloride tracheal tube.
Sharma MU; Gombar S; Gombar KK; Singh B; Bhatia N
Indian J Anaesth; 2013 Jan; 57(1):19-24. PubMed ID: 23716761
[TBL] [Abstract][Full Text] [Related]
4. Ease of endotracheal intubation with the conventional polyvinyl chloride endotracheal tube versus wire-reinforced flexometallic tube through the intubating laryngeal mask airway: A comparative study.
Kalvapudi D; Archana KN; Manjunatha Swamy AH; Kumararadhya GB; Shivakumar KG
Ann Afr Med; 2024; 23(1):70-75. PubMed ID: 38358174
[TBL] [Abstract][Full Text] [Related]
5. A comparison of a silicone wire-reinforced tube with the Parker and polyvinyl chloride tubes for tracheal intubation through an intubating laryngeal mask airway in patients with normal airways undergoing general anesthesia.
Kanazi GE; El-Khatib M; Nasr VG; Kaddoum R; Al-Alami A; Baraka AS; Ayoub CM
Anesth Analg; 2008 Sep; 107(3):994-7. PubMed ID: 18713919
[TBL] [Abstract][Full Text] [Related]
6. Evaluation of the Effect of Tracheal Tube Orientation on Success of Intubation through Intubating Laryngeal Mask Airway.
Chhatrapati S; Sahu A; Auti SS; Aswar SG
J Clin Diagn Res; 2016 May; 10(5):UC06-9. PubMed ID: 27437330
[TBL] [Abstract][Full Text] [Related]
7. A comparison of blind intubation with the intubating laryngeal mask FASTRACH™ and the intubating laryngeal mask Ambu Aura-i™ a prospective randomised clinical trial.
Schiewe R; Stoeck M; Gruenewald M; Hoecker J; Bein B
BMC Anesthesiol; 2019 Mar; 19(1):44. PubMed ID: 30927922
[TBL] [Abstract][Full Text] [Related]
8. The intubating laryngeal mask airway with and without fiberoptic guidance.
Joo HS; Rose DK
Anesth Analg; 1999 Mar; 88(3):662-6. PubMed ID: 10072024
[TBL] [Abstract][Full Text] [Related]
9. Use of the intubating laryngeal mask airway: are muscle relaxants necessary?
van Vlymen JM; Coloma M; Tongier WK; White PF
Anesthesiology; 2000 Aug; 93(2):340-5. PubMed ID: 10910479
[TBL] [Abstract][Full Text] [Related]
10. The intubating LMA: a comparison of insertion techniques with conventional tracheal tubes.
Lu PP; Yang CH; Ho AC; Shyr MH
Can J Anaesth; 2000 Sep; 47(9):849-53. PubMed ID: 10989853
[TBL] [Abstract][Full Text] [Related]
11. Effects of tracheal tube orientation on the success of intubation through an intubating laryngeal mask airway: study in Mallampati class 3 or 4 patients.
Ye L; Liu J; Wong DT; Zhu T
Br J Anaesth; 2009 Feb; 102(2):269-72. PubMed ID: 19151052
[TBL] [Abstract][Full Text] [Related]
12. [Roles of Cookgas and Fastrach intubating laryngeal mask airway for anticipated difficult tracheal intubation].
Yang D; Deng XM; Tong SY; Tang GZ; Wei LX; Sui JH; Wang L
Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2013 Apr; 35(2):207-12. PubMed ID: 23643011
[TBL] [Abstract][Full Text] [Related]
13. [First experience with the laryngeal intubation mask].
Langenstein H; Möller F
Anaesthesist; 1998 Apr; 47(4):311-9. PubMed ID: 9615848
[TBL] [Abstract][Full Text] [Related]
14. Flexible optical intubation via the Ambu Aura-i vs blind intubation via the single-use LMA Fastrach: a prospective randomized clinical trial.
Artime CA; Altamirano A; Normand KC; Ferrario L; Aijazi H; Cattano D; Hagberg CA
J Clin Anesth; 2016 Sep; 33():41-6. PubMed ID: 27555131
[TBL] [Abstract][Full Text] [Related]
15. Mallampati class does not affect the success rate of intubation through an intubating laryngeal mask airway with reverse tracheal tube direction.
Ye L; Wong DT; Liu J; Zhu T
Minerva Anestesiol; 2013 Mar; 79(3):227-31. PubMed ID: 23174918
[TBL] [Abstract][Full Text] [Related]
16. The intubating laryngeal mask airway facilitates tracheal intubation in the lateral position.
Komatsu R; Nagata O; Sessler DI; Ozaki M
Anesth Analg; 2004 Mar; 98(3):858-61, table of contents. PubMed ID: 14980953
[TBL] [Abstract][Full Text] [Related]
17. Comparison between Air Q and intubating laryngeal mask airway as intubation conduits in patients with simulated fixed cervical spine: a prospective observational study.
Bala R; Basumatary J; Bansal P
Med Gas Res; 2023; 13(1):10-14. PubMed ID: 35946217
[TBL] [Abstract][Full Text] [Related]
18. Use of the intubating laryngeal mask in children: an evaluation using video-endoscopic monitoring.
Weiss M; Schwarz U; Dillier C; Fischer J; Gerber AC
Eur J Anaesthesiol; 2001 Nov; 18(11):739-44. PubMed ID: 11580780
[TBL] [Abstract][Full Text] [Related]
19. Comparison of a polyvinyl chloride tube with a wire-reinforced tube for tracheal intubation through the SaCoVLM video laryngeal mask airway: protocol for a randomised controlled study.
Gao Z; Guo Y; Gao X; Wang W; Zhang M; Liu MJ; Chen L; Liu Y; Zhang X; Sun Y; Wang Y
BMJ Open; 2022 Dec; 12(12):e066084. PubMed ID: 36517088
[TBL] [Abstract][Full Text] [Related]
20. Awake tracheal intubation in anticipated difficult airways: LMA Fastrach vs flexible bronchoscope: A pilot study.
Hanna SF; Mikat-Stevens M; Loo J; Uppal R; Jellish WS; Adams M
J Clin Anesth; 2017 Feb; 37():31-37. PubMed ID: 28235524
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]