109 related articles for article (PubMed ID: 15621649)
1. A method for material parameter determination for the human mandible based on simulation and experiment.
Clason C; Hinz AM; Schieferstein H
Comput Methods Biomech Biomed Engin; 2004 Oct; 7(5):265-76. PubMed ID: 15621649
[TBL] [Abstract][Full Text] [Related]
2. Analysis of the effects of different materials in a tooth implant-supported fixed prosthesis using finite element method.
Dargahi J; Najarian S; Talebi M
Biomed Mater Eng; 2005; 15(4):317-31. PubMed ID: 16010040
[TBL] [Abstract][Full Text] [Related]
3. Influence of bone and dental implant parameters on stress distribution in the mandible: a finite element study.
Guan H; van Staden R; Loo YC; Johnson N; Ivanovski S; Meredith N
Int J Oral Maxillofac Implants; 2009; 24(5):866-76. PubMed ID: 19865627
[TBL] [Abstract][Full Text] [Related]
4. The biomechanics of human femurs in axial and torsional loading: comparison of finite element analysis, human cadaveric femurs, and synthetic femurs.
Papini M; Zdero R; Schemitsch EH; Zalzal P
J Biomech Eng; 2007 Feb; 129(1):12-9. PubMed ID: 17227093
[TBL] [Abstract][Full Text] [Related]
5. Flexural and creep properties of human jaw compact bone for FEA studies.
Vitins V; Dobelis M; Middleton J; Limbert G; Knets I
Comput Methods Biomech Biomed Engin; 2003; 6(5-6):299-303. PubMed ID: 14675950
[TBL] [Abstract][Full Text] [Related]
6. Probabilistic analysis of peri-implant strain predictions as influenced by uncertainties in bone properties and occlusal forces.
Petrie CS; Williams JL
Clin Oral Implants Res; 2007 Oct; 18(5):611-9. PubMed ID: 17590159
[TBL] [Abstract][Full Text] [Related]
7. Mechanical characterization of contact lenses by microindentation: Constant velocity and relaxation testing.
Lee SJ; Bourne GR; Chen X; Sawyer WG; Sarntinoranont M
Acta Biomater; 2008 Sep; 4(5):1560-8. PubMed ID: 18406673
[TBL] [Abstract][Full Text] [Related]
8. Geometric and material nonlinearity in tensioned wires of an external fixator.
Zhang G
Clin Biomech (Bristol, Avon); 2004 Jun; 19(5):513-8. PubMed ID: 15182987
[TBL] [Abstract][Full Text] [Related]
9. Geometric element analysis of fretting in a model of a modular femoral component of a hip implant.
Lewis G
Biomed Mater Eng; 2004; 14(1):43-51. PubMed ID: 14757952
[TBL] [Abstract][Full Text] [Related]
10. Nonlinear elastic material property estimation of lower extremity residual limb tissues.
Tönük E; Silver-Thorn MB
IEEE Trans Neural Syst Rehabil Eng; 2003 Mar; 11(1):43-53. PubMed ID: 12797725
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of multiple implant-bone parameters on stress characteristics in the mandible under traumatic loading conditions.
Guan H; van Staden R; Loo YC; Johnson N; Ivanovski S; Meredith N
Int J Oral Maxillofac Implants; 2010; 25(3):461-72. PubMed ID: 20556244
[TBL] [Abstract][Full Text] [Related]
12. Design of monolimb using finite element modelling and statistics-based Taguchi method.
Lee WC; Zhang M
Clin Biomech (Bristol, Avon); 2005 Aug; 20(7):759-66. PubMed ID: 15963612
[TBL] [Abstract][Full Text] [Related]
13. Intramedullary femoral nails: one or two lag screws? A preliminary study.
Paul JP
Med Eng Phys; 2004 May; 26(4):359; author reply 360. PubMed ID: 15121063
[No Abstract] [Full Text] [Related]
14. Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis.
Tada S; Stegaroiu R; Kitamura E; Miyakawa O; Kusakari H
Int J Oral Maxillofac Implants; 2003; 18(3):357-68. PubMed ID: 12814310
[TBL] [Abstract][Full Text] [Related]
15. Bivariate evaluation of cylinder implant diameter and length: a three-dimensional finite element analysis.
Kong L; Sun Y; Hu K; Li D; Hou R; Yang J; Liu B
J Prosthodont; 2008 Jun; 17(4):286-93. PubMed ID: 18205741
[TBL] [Abstract][Full Text] [Related]
16. The dynamics of a non-equilibrium bubble near bio-materials.
Ohl SW; Klaseboer E; Khoo BC
Phys Med Biol; 2009 Oct; 54(20):6313-36. PubMed ID: 19809103
[TBL] [Abstract][Full Text] [Related]
17. Effect of a thin HA coating on the stress/strain distribution in bone around dental implants using three-dimensional finite element analysis.
Aoki H; Ozeki K; Ohtani Y; Fukui Y; Asaoka T
Biomed Mater Eng; 2006; 16(3):157-69. PubMed ID: 16518015
[TBL] [Abstract][Full Text] [Related]
18. Stress and strain distribution behavior in the bone due to the effect of cancellous bone, dental implant material and the bone height.
Hedia HS
Biomed Mater Eng; 2002; 12(2):111-9. PubMed ID: 12122235
[TBL] [Abstract][Full Text] [Related]
19. Bone ingrowth simulation for a concept glenoid component design.
Andreykiv A; Prendergast PJ; van Keulen F; Swieszkowski W; Rozing PM
J Biomech; 2005 May; 38(5):1023-33. PubMed ID: 15797584
[TBL] [Abstract][Full Text] [Related]
20. Finite element analysis of 2 immediate loading systems in edentulous mandible: rigid and semirigid splinting of implants.
Teixeira MF; Ramalho SA; de Mattias Sartori IA; Lehmann RB
Implant Dent; 2010 Feb; 19(1):39-49. PubMed ID: 20147815
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]