126 related articles for article (PubMed ID: 15625819)
1. A simple method of bronchoprovocation using a valved holding chamber.
Taivans I; Jurka N; Strazda G; Brezinskis G
J Aerosol Med; 2004; 17(3):270-7. PubMed ID: 15625819
[TBL] [Abstract][Full Text] [Related]
2. A new aerosol device for bronchial provocation tests.
Matthys H; Knoch M; Eltschka R
Respiration; 1993; 60(6):343-50. PubMed ID: 8290799
[TBL] [Abstract][Full Text] [Related]
3. Effect of nebulizer configuration on delivery of aerosolized tobramycin.
O'Riordan TG; Amram JC
J Aerosol Med; 1997; 10(1):13-23. PubMed ID: 10166359
[TBL] [Abstract][Full Text] [Related]
4. Aerosolized protein delivery in asthma: gamma camera analysis of regional deposition and perfusion.
Sangwan S; Agosti JM; Bauer LA; Otulana BA; Morishige RJ; Cipolla DC; Blanchard JD; Smaldone GC
J Aerosol Med; 2001; 14(2):185-95. PubMed ID: 11681650
[TBL] [Abstract][Full Text] [Related]
5. SPECT-CT Comparison of Lung Deposition using a System combining a Vibrating-mesh Nebulizer with a Valved Holding Chamber and a Conventional Jet Nebulizer: a Randomized Cross-over Study.
Dugernier J; Hesse M; Vanbever R; Depoortere V; Roeseler J; Michotte JB; Laterre PF; Jamar F; Reychler G
Pharm Res; 2017 Feb; 34(2):290-300. PubMed ID: 27822851
[TBL] [Abstract][Full Text] [Related]
6. Capturing the efficiency of vibrating mesh nebulizers: minimizing upper airway deposition.
Sagalla RB; Smaldone GC
J Aerosol Med Pulm Drug Deliv; 2014 Oct; 27(5):341-8. PubMed ID: 25105472
[TBL] [Abstract][Full Text] [Related]
7. Does Valved Holding Chamber Improve Aerosol Lung Deposition with a Jet Nebulizer? A Randomized Crossover Study.
Alcoforado L; Paiva DN; Ari A; Barcelar JM; Brandão SCS; Fink JB; Dornelas de Andrade A
Pharmaceutics; 2022 Mar; 14(3):. PubMed ID: 35335942
[TBL] [Abstract][Full Text] [Related]
8. Positive expiratory pressure changes aerosol distribution in patients with cystic fibrosis.
Laube BL; Geller DE; Lin TC; Dalby RN; Diener-West M; Zeitlin PL
Respir Care; 2005 Nov; 50(11):1438-44. PubMed ID: 16253150
[TBL] [Abstract][Full Text] [Related]
9. A novel, versatile valved holding chamber for delivering inhaled medications to neonates and small children: laboratory simulation of delivery options.
DiBlasi RM; Coppolo DP; Nagel MW; Doyle CC; Avvakoumova VI; Ali RS; Mitchell JP
Respir Care; 2010 Apr; 55(4):419-26. PubMed ID: 20406509
[TBL] [Abstract][Full Text] [Related]
10. Aerosol deposition in infants with cystic fibrosis.
Mallol J; Rattray S; Walker G; Cook D; Robertson CF
Pediatr Pulmonol; 1996 May; 21(5):276-81. PubMed ID: 8726152
[TBL] [Abstract][Full Text] [Related]
11. Lung deposition and respirable mass during wet nebulization.
Sangwan S; Condos R; Smaldone GC
J Aerosol Med; 2003; 16(4):379-86. PubMed ID: 14977428
[TBL] [Abstract][Full Text] [Related]
12. Mode of breathing-tidal or slow and deep-through the I-neb Adaptive Aerosol Delivery (AAD) system affects lung deposition of (99m)Tc-DTPA.
Nikander K; Prince I; Coughlin S; Warren S; Taylor G
J Aerosol Med Pulm Drug Deliv; 2010 Apr; 23 Suppl 1(Suppl 1):S37-43. PubMed ID: 20373908
[TBL] [Abstract][Full Text] [Related]
13. [Comparative studies of airway deposition of 99mTc-DTPA aerosol particles among 4 different nebulizers by pulmonary scintillation method].
Yamaguchi H; Shiigai N; Mitsubayashi K; Oosika E; Okada F; Mitsubayashi T; Sasaki N; Iseya O; Miyamae T; Suzuki I; Akasaka T
Arerugi; 1997 Oct; 46(10):1052-7. PubMed ID: 9404093
[TBL] [Abstract][Full Text] [Related]
14. The challenges of quantitative measurement of lung deposition using 99mTc-DTPA from delivery systems with very different delivery times.
Coates AL; Green M; Leung K; Louca E; Tservistas M; Chan J; Ribeiro N; Charron M
J Aerosol Med; 2007; 20(3):320-30. PubMed ID: 17894538
[TBL] [Abstract][Full Text] [Related]
15. [Aerosol deposit sample in aspecific bronchial provocation test: a nuclear medicine study for quantification].
Eltschka R; App E; Köhler D; Popov T; Matthys H
Pneumologie; 1991 Aug; 45 Suppl 2():654-8. PubMed ID: 1946272
[TBL] [Abstract][Full Text] [Related]
16. Improved efficacy of aerosol delivery to distal airways in pediatric subjects using a new spacer mouth-mask.
Yüksel H; Berardino L; Yüksel D; Yilmaz O; Burak Z
Eur Ann Allergy Clin Immunol; 2007 Feb; 39(2):64-8. PubMed ID: 17441418
[TBL] [Abstract][Full Text] [Related]
17. Effect of drug targeting nebulization on lung deposition: a randomized crossover scintigraphic comparison between central and peripheral delivery.
Reychler G; Aubriot AS; Depoortere V; Jamar F; Liistro G
Respir Care; 2014 Oct; 59(10):1501-7. PubMed ID: 25161302
[TBL] [Abstract][Full Text] [Related]
18. Effect of pattern of aerosol inhalation on clearance of technetium-99m-labeled diethylenetriamine pentaacetic acid from the lungs of normal humans.
Smith RJ; Hyde RW; Waldman DL; Freund GG; Weber DA; Utell MJ; Morrow PE
Am Rev Respir Dis; 1992 May; 145(5):1109-16. PubMed ID: 1586055
[TBL] [Abstract][Full Text] [Related]
19. Accounting for radioactivity before and after nebulization of tobramycin to insure accuracy of quantification of lung deposition.
Coates AL; Dinh L; MacNeish CF; Rollin T; Gagnon S; Ho SL; Lands LC
J Aerosol Med; 2000; 13(3):169-78. PubMed ID: 11066020
[TBL] [Abstract][Full Text] [Related]
20. The effect of breathing frequency on deposition of drug aerosol using an inhalation-synchronized dosimeter in healthy adults.
Häkkinen AM; Uusi-Heikkilä H; Järvinen M; Saali K; Karhumäki L
Clin Physiol; 1999 May; 19(3):269-74. PubMed ID: 10361618
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]