969 related articles for article (PubMed ID: 15626601)
1. Microchamber array based DNA quantification and specific sequence detection from a single copy via PCR in nanoliter volumes.
Matsubara Y; Kerman K; Kobayashi M; Yamamura S; Morita Y; Tamiya E
Biosens Bioelectron; 2005 Feb; 20(8):1482-90. PubMed ID: 15626601
[TBL] [Abstract][Full Text] [Related]
2. On-chip nanoliter-volume multiplex TaqMan polymerase chain reaction from a single copy based on counting fluorescence released microchambers.
Matsubara Y; Kerman K; Kobayashi M; Yamamura S; Morita Y; Takamura Y; Tamiya E
Anal Chem; 2004 Nov; 76(21):6434-9. PubMed ID: 15516138
[TBL] [Abstract][Full Text] [Related]
3. Quantitative PCR based expression analysis on a nanoliter scale using polymer nano-well chips.
Dahl A; Sultan M; Jung A; Schwartz R; Lange M; Steinwand M; Livak KJ; Lehrach H; Nyarsik L
Biomed Microdevices; 2007 Jun; 9(3):307-14. PubMed ID: 17203381
[TBL] [Abstract][Full Text] [Related]
4. Real time PCR on disposable PDMS chip with a miniaturized thermal cycler.
Xiang Q; Xu B; Fu R; Li D
Biomed Microdevices; 2005 Dec; 7(4):273-9. PubMed ID: 16404505
[TBL] [Abstract][Full Text] [Related]
5. Electrohydrodynamic (EHD) dispensing of nanoliter DNA droplets for microarrays.
Lee JG; Cho HJ; Huh N; Ko C; Lee WC; Jang YH; Lee BS; Kang IS; Choi JW
Biosens Bioelectron; 2006 Jun; 21(12):2240-7. PubMed ID: 16384694
[TBL] [Abstract][Full Text] [Related]
6. Real-time PCR microfluidic devices with concurrent electrochemical detection.
Fang TH; Ramalingam N; Xian-Dui D; Ngin TS; Xianting Z; Lai Kuan AT; Peng Huat EY; Hai-Qing G
Biosens Bioelectron; 2009 Mar; 24(7):2131-6. PubMed ID: 19162460
[TBL] [Abstract][Full Text] [Related]
7. Real-time electrochemical monitoring of the polymerase chain reaction by mediated redox catalysis.
Deféver T; Druet M; Rochelet-Dequaire M; Joannes M; Grossiord C; Limoges B; Marchal D
J Am Chem Soc; 2009 Aug; 131(32):11433-41. PubMed ID: 19722651
[TBL] [Abstract][Full Text] [Related]
8. On-chip PCR amplification of very long templates using immobilized primers on glassy surfaces.
von Nickisch-Rosenegk M; Marschan X; Andresen D; Abraham A; Heise C; Bier FF
Biosens Bioelectron; 2005 Feb; 20(8):1491-8. PubMed ID: 15626602
[TBL] [Abstract][Full Text] [Related]
9. On-chip oligonucleotide ligation assay using one-dimensional microfluidic beads array for the detection of low-abundant DNA point mutations.
Zhang H; Yang X; Wang K; Tan W; Li H; Zuo X; Wen J
Biosens Bioelectron; 2008 Feb; 23(7):945-51. PubMed ID: 17983740
[TBL] [Abstract][Full Text] [Related]
10. Multiplexed detection and differentiation of the DNA strains for influenza A (H1N1 2009) using a silicon-based microfluidic system.
Kao LT; Shankar L; Kang TG; Zhang G; Tay GK; Rafei SR; Lee CW
Biosens Bioelectron; 2011 Jan; 26(5):2006-11. PubMed ID: 20888214
[TBL] [Abstract][Full Text] [Related]
11. Label-free quantitative DNA detection using the liquid core optical ring resonator.
Suter JD; White IM; Zhu H; Shi H; Caldwell CW; Fan X
Biosens Bioelectron; 2008 Feb; 23(7):1003-9. PubMed ID: 18036809
[TBL] [Abstract][Full Text] [Related]
12. Microfluidic handling of PCR solution and DNA amplification on a reaction chamber array biochip.
Gong H; Ramalingam N; Chen L; Che J; Wang Q; Wang Y; Yang X; Yap PH; Neo CH
Biomed Microdevices; 2006 Jun; 8(2):167-76. PubMed ID: 16688576
[TBL] [Abstract][Full Text] [Related]
13. Development of a temperature sensor array chip and a chip-based real-time PCR machine for DNA amplification efficiency-based quantification.
Lee DS; Chen CS
Biosens Bioelectron; 2008 Feb; 23(7):971-9. PubMed ID: 18042374
[TBL] [Abstract][Full Text] [Related]
14. A microsystem compatible strategy for viable Escherichia coli detection.
Zhao W; Yao S; Hsing IM
Biosens Bioelectron; 2006 Jan; 21(7):1163-70. PubMed ID: 15927460
[TBL] [Abstract][Full Text] [Related]
15. A novel fluorescence-based array biosensor: principle and application to DNA hybridization assays.
Schultz E; Galland R; Du Bouëtiez D; Flahaut T; Planat-Chrétien A; Lesbre F; Hoang A; Volland H; Perraut F
Biosens Bioelectron; 2008 Feb; 23(7):987-94. PubMed ID: 18207730
[TBL] [Abstract][Full Text] [Related]
16. Electrochemical microfluidic biosensor for the detection of nucleic acid sequences.
Goral VN; Zaytseva NV; Baeumner AJ
Lab Chip; 2006 Mar; 6(3):414-21. PubMed ID: 16511625
[TBL] [Abstract][Full Text] [Related]
17. A disposable and cost efficient microfluidic device for the rapid chip-based electrical detection of DNA.
Schüler T; Kretschmer R; Jessing S; Urban M; Fritzsche W; Möller R; Popp J
Biosens Bioelectron; 2009 Sep; 25(1):15-21. PubMed ID: 19592230
[TBL] [Abstract][Full Text] [Related]
18. Electrochemical microfluidic biosensor for nucleic acid detection with integrated minipotentiostat.
Kwakye S; Goral VN; Baeumner AJ
Biosens Bioelectron; 2006 Jun; 21(12):2217-23. PubMed ID: 16386889
[TBL] [Abstract][Full Text] [Related]
19. Liquid-based hybridization assay with real-time detection in miniaturized array platforms.
Guerasimova A; Nyarsik L; Liu JP; Schwartz R; Lange M; Lehrach H; Janitz M
Biomol Eng; 2006 Mar; 23(1):35-40. PubMed ID: 16298548
[TBL] [Abstract][Full Text] [Related]
20. Biofunctional subwavelength optical waveguides for biodetection.
Sirbuly DJ; Fischer NO; Huang SC; Artyukhin AB; Tok JB; Bakajin O; Noy A
ACS Nano; 2008 Feb; 2(2):255-62. PubMed ID: 19206625
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]