BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

686 related articles for article (PubMed ID: 15629814)

  • 1. Pattern electroretinogram abnormality and glaucoma.
    Ventura LM; Porciatti V; Ishida K; Feuer WJ; Parrish RK
    Ophthalmology; 2005 Jan; 112(1):10-9. PubMed ID: 15629814
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Role of Pattern Electroretinogram in Ocular Hypertension and Early Glaucoma.
    Turkey E; Elsanabary ZSE; Elshazly LHM; Osman MH
    J Glaucoma; 2019 Oct; 28(10):871-877. PubMed ID: 31306362
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Detection of optic neuropathy in glaucomatous eyes with normal standard visual fields using a test battery of short-wavelength automated perimetry and pattern electroretinography.
    Bayer AU; Maag KP; Erb C
    Ophthalmology; 2002 Jul; 109(7):1350-61. PubMed ID: 12093662
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical ability of pattern electroretinograms and visual evoked potentials in detecting visual dysfunction in ocular hypertension and glaucoma.
    Parisi V; Miglior S; Manni G; Centofanti M; Bucci MG
    Ophthalmology; 2006 Feb; 113(2):216-28. PubMed ID: 16406535
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Restoration of retinal ganglion cell function in early glaucoma after intraocular pressure reduction: a pilot study.
    Ventura LM; Porciatti V
    Ophthalmology; 2005 Jan; 112(1):20-7. PubMed ID: 15629815
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The relationship between retinal ganglion cell function and retinal nerve fiber thickness in early glaucoma.
    Ventura LM; Sorokac N; De Los Santos R; Feuer WJ; Porciatti V
    Invest Ophthalmol Vis Sci; 2006 Sep; 47(9):3904-11. PubMed ID: 16936103
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Short wavelength automated perimetry, frequency doubling technology perimetry, and pattern electroretinography for prediction of progressive glaucomatous standard visual field defects.
    Bayer AU; Erb C
    Ophthalmology; 2002 May; 109(5):1009-17. PubMed ID: 11986111
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Correlation of frequency-doubling perimetry with retinal nerve fiber layer thickness and optic disc size in ocular hypertensives and glaucoma suspects.
    Kaushik S; Pandav SS; Ichhpujani P; Gupta A
    J Glaucoma; 2011 Aug; 20(6):366-70. PubMed ID: 20717056
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pattern electroretinogram and computerized optic nerve-head analysis in glaucoma suspects.
    Bach M; Funk J
    Ger J Ophthalmol; 1993 May; 2(3):178-81. PubMed ID: 8334394
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ganglion cell loss in early glaucoma, as assessed by photopic negative response, pattern electroretinogram, and spectral-domain optical coherence tomography.
    Cvenkel B; Sustar M; Perovšek D
    Doc Ophthalmol; 2017 Aug; 135(1):17-28. PubMed ID: 28567618
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of optic nerve head topography and visual field in eyes with open-angle and angle-closure glaucoma.
    Boland MV; Zhang L; Broman AT; Jampel HD; Quigley HA
    Ophthalmology; 2008 Feb; 115(2):239-245.e2. PubMed ID: 18082888
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Detection of psychophysical and structural injury in eyes with glaucomatous optic neuropathy and normal standard automated perimetry.
    Bagga H; Feuer WJ; Greenfield DS
    Arch Ophthalmol; 2006 Feb; 124(2):169-76. PubMed ID: 16476885
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pattern ERG as an early glaucoma indicator in ocular hypertension: a long-term, prospective study.
    Bach M; Unsoeld AS; Philippin H; Staubach F; Maier P; Walter HS; Bomer TG; Funk J
    Invest Ophthalmol Vis Sci; 2006 Nov; 47(11):4881-7. PubMed ID: 17065502
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparing multifocal VEP and standard automated perimetry in high-risk ocular hypertension and early glaucoma.
    Fortune B; Demirel S; Zhang X; Hood DC; Patterson E; Jamil A; Mansberger SL; Cioffi GA; Johnson CA
    Invest Ophthalmol Vis Sci; 2007 Mar; 48(3):1173-80. PubMed ID: 17325161
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Retinal nerve fiber layer thickness measurements with scanning laser polarimetry predict glaucomatous visual field loss.
    Mohammadi K; Bowd C; Weinreb RN; Medeiros FA; Sample PA; Zangwill LM
    Am J Ophthalmol; 2004 Oct; 138(4):592-601. PubMed ID: 15488786
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Long-term PERG monitoring of untreated and treated glaucoma suspects.
    Gordon PS; Kostic M; Monsalve PF; Triolo G; Golubev L; Luna G; Ventura LM; Feuer WJ; Porciatti V
    Doc Ophthalmol; 2020 Oct; 141(2):149-156. PubMed ID: 32152920
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pattern electroretinogram progression in glaucoma suspects.
    Ventura LM; Golubev I; Feuer WJ; Porciatti V
    J Glaucoma; 2013 Mar; 22(3):219-25. PubMed ID: 22071557
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Retinal vessel diameter and open-angle glaucoma: the Blue Mountains Eye Study.
    Mitchell P; Leung H; Wang JJ; Rochtchina E; Lee AJ; Wong TY; Klein R
    Ophthalmology; 2005 Feb; 112(2):245-50. PubMed ID: 15691558
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Correlation of pattern electroretinogram with optic disc cup shape in ocular hypertension.
    Salgarello T; Colotto A; Falsini B; Buzzonetti L; Cesari L; Iarossi G; Scullica L
    Invest Ophthalmol Vis Sci; 1999 Aug; 40(9):1989-97. PubMed ID: 10440253
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Retinal ganglion cells function measured by the PERG test in patients with ocular hypertension.
    Wojciech L; Wojciech G; Krzysztof P; Zbigniew S; Danuta K
    Klin Oczna; 2011; 113(4-6):122-6. PubMed ID: 21913439
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 35.