These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
103 related articles for article (PubMed ID: 1563139)
1. Dissociation of modular hip arthroplasty components after dislocation. A report of three cases at differing dissociation levels. Star MJ; Colwell CW; Donaldson WF; Walker RH Clin Orthop Relat Res; 1992 May; (278):111-5. PubMed ID: 1563139 [TBL] [Abstract][Full Text] [Related]
2. Dissociation of modular total hip arthroplasty at the femoral head-neck interface after loosening of the acetabular shell following hip dislocation. Chu CM; Wang SJ; Lin LC J Arthroplasty; 2001 Sep; 16(6):806-9. PubMed ID: 11547382 [TBL] [Abstract][Full Text] [Related]
3. Late dissociation of the polyethylene liner from a modular acetabular metal shell after primary total hip arthroplasty--a report of five cases. Han CD; Choe WS; Yoo JH Yonsei Med J; 1998 Jun; 39(3):277-82. PubMed ID: 9664834 [TBL] [Abstract][Full Text] [Related]
4. [Dislocation-dissociation of a bipolar hip prosthesis]. Corteel J; Putz P Acta Orthop Belg; 1996 Sep; 62(3):173-6. PubMed ID: 8967298 [TBL] [Abstract][Full Text] [Related]
5. Dissociation of the modular femoral stem from the metaphyseal sleeve during reduction of a total hip arthroplasty dislocation. Fanuele J; Bernini P J Arthroplasty; 2007 Jan; 22(1):140-2. PubMed ID: 17197322 [TBL] [Abstract][Full Text] [Related]
6. [Dissociation of a modular acetabular component in an uncemented total hip prosthesis. Effect of the modular design and anti-luxation rim. A case report]. Blanco Blanco J; Tapia Casado L; Ramos Galea R; Léon Vasquez F Rev Chir Orthop Reparatrice Appar Mot; 1999 Jun; 85(3):302-5. PubMed ID: 10422137 [TBL] [Abstract][Full Text] [Related]
7. Dislocation rate after conversion from hip hemiarthroplasty to total hip arthroplasty. Sah AP; Estok DM J Bone Joint Surg Am; 2008 Mar; 90(3):506-16. PubMed ID: 18310700 [TBL] [Abstract][Full Text] [Related]
8. Dissociation of bipolar hemiarthroplasty of the hip after dislocation. A report of five different cases and review of literature. Georgiou G; Siapkara A; Dimitrakopoulou A; Provelengios S; Dounis E Injury; 2006 Feb; 37(2):162-8. PubMed ID: 16420955 [TBL] [Abstract][Full Text] [Related]
9. [Bousquet's device in the treatment of recurrent dislocation of a total hip prosthesis. Apropos of 13 cases]. Leclercq S; el Blidi S; Aubriot JH Rev Chir Orthop Reparatrice Appar Mot; 1995; 81(5):389-94. PubMed ID: 8560007 [TBL] [Abstract][Full Text] [Related]
10. Spontaneous modular femoral head dissociation complicating total hip arthroplasty. Talmo CT; Sharp KG; Malinowska M; Bono JV; Ward DM; LaReau J Orthopedics; 2014 Jun; 37(6):e592-5. PubMed ID: 24972443 [TBL] [Abstract][Full Text] [Related]
11. Disassembly of a modular femoral component during closed reduction of the dislocated femoral component. A case report. Pellicci PM; Haas SB J Bone Joint Surg Am; 1990 Apr; 72(4):619-20. PubMed ID: 2324149 [No Abstract] [Full Text] [Related]
12. Fixation, survival, and dislocation of jumbo acetabular components in revision hip arthroplasty. Lachiewicz PF; Soileau ES J Bone Joint Surg Am; 2013 Mar; 95(6):543-8. PubMed ID: 23515989 [TBL] [Abstract][Full Text] [Related]
13. Dual mobility cups hip arthroplasty as a treatment for displaced fracture of the femoral neck in the elderly. A prospective, systematic, multicenter study with specific focus on postoperative dislocation. Adam P; Philippe R; Ehlinger M; Roche O; Bonnomet F; Molé D; Fessy MH; Orthop Traumatol Surg Res; 2012 May; 98(3):296-300. PubMed ID: 22463868 [TBL] [Abstract][Full Text] [Related]
14. Early intraprosthetic dislocation in a revision dual-mobility hip prosthesis. Banka TR; Ast MP; Parks ML Orthopedics; 2014 Apr; 37(4):e395-7. PubMed ID: 24762847 [TBL] [Abstract][Full Text] [Related]
15. Component dissociation after closed reduction of dual mobility sockets - a report of three cases. Stigbrand H; Ullmark G Hip Int; 2011; 21(2):263-6. PubMed ID: 21484735 [TBL] [Abstract][Full Text] [Related]
16. Disassembly of a modular femoral prosthesis after dislocation of the femoral component. A case report. Woolson ST; Pottorff GT J Bone Joint Surg Am; 1990 Apr; 72(4):624-5. PubMed ID: 2324151 [No Abstract] [Full Text] [Related]
17. Five cases of early dissociation between the bipolar hip endoprosthesis cup components; either spontaneously or during reduction maneuvers. Uruç V; Özden R; Duman İG; Kalacı A Acta Orthop Traumatol Turc; 2017 Mar; 51(2):172-176. PubMed ID: 28236546 [TBL] [Abstract][Full Text] [Related]
18. Damage of oxinium femoral heads subsequent to hip arthroplasty dislocation three retrieval case studies. Kop AM; Whitewood C; Johnston DJ J Arthroplasty; 2007 Aug; 22(5):775-9. PubMed ID: 17689792 [TBL] [Abstract][Full Text] [Related]
19. Late disassembly of a modular acetabular component. A case report. O'Brien RF; Chess D J Arthroplasty; 1992; 7 Suppl():453-5. PubMed ID: 1431931 [TBL] [Abstract][Full Text] [Related]
20. Dissociation of bipolar components following bipolar hemiarthroplasty: A report of two different cases and review of the literature. Sevinç HF Ulus Travma Acil Cerrahi Derg; 2021 Sep; 27(5):600-603. PubMed ID: 34476791 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]