These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 15636399)

  • 1. A runny nose: an unexpected ferromagnetic foreign body in an unexpected place.
    Rodolà F; Anastasi F
    Eur Rev Med Pharmacol Sci; 2004; 8(4):139-41. PubMed ID: 15636399
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Metallic foreign bodies in the orbits of patients undergoing MR imaging: prevalence and value of radiography and CT before MR.
    Williamson MR; Espinosa MC; Boutin RD; Orrison WW; Hart BL; Kelsey CA
    AJR Am J Roentgenol; 1994 Apr; 162(4):981-3. PubMed ID: 8141030
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Re: Metallic foreign bodies in the orbits of patients undergoing MR imaging: prevalence and value of radiography and CT before MR.
    Shellock FG; Kanal E
    AJR Am J Roentgenol; 1994 Apr; 162(4):985-6. PubMed ID: 8141031
    [No Abstract]   [Full Text] [Related]  

  • 4. Injuries associated with MR imaging: survey of safety records and methods used to screen patients for metallic foreign bodies before imaging.
    Boutin RD; Briggs JE; Williamson MR
    AJR Am J Roentgenol; 1994 Jan; 162(1):189-94. PubMed ID: 8273663
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An unexpected ferromagnetic foreign body detected during emergency magnetic resonance imaging: a case report.
    Metterlein T; Haubner F; Knoppke B; Graf B; Zausig Y
    BMC Res Notes; 2014 Nov; 7():808. PubMed ID: 25403316
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Magnetic foreign body on the nasal septum.
    Jonas NE; Meyer E
    S Afr J Surg; 2007 Nov; 45(4):151. PubMed ID: 18069584
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Intracranial metal foreign bodies and contraindications of MRI. Apropos of a case].
    Viana-Fernandes CE; Iffenecker C; Doyon D
    J Radiol; 1998 Aug; 79(8):764-6. PubMed ID: 9757308
    [TBL] [Abstract][Full Text] [Related]  

  • 8. MR imaging of a patient with a ferromagnetic foreign body.
    Dupuy DE; Hartnell GG; Lipsky M
    AJR Am J Roentgenol; 1993 Apr; 160(4):893. PubMed ID: 8456685
    [No Abstract]   [Full Text] [Related]  

  • 9. Foreign body impaction: fifty years inside the nose.
    Pitsinis V; Patel A
    Ear Nose Throat J; 2004 Aug; 83(8):564, 566. PubMed ID: 15487637
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Incidental finding of a metallic nasal foreign body during MRI.
    Shailesh S; Shah S; Gopalkrishnan S; Sangari T
    Paediatr Anaesth; 2008 Aug; 18(8):803-4. PubMed ID: 18482247
    [No Abstract]   [Full Text] [Related]  

  • 11. Aneurysm clip testing for ferromagnetic properties: clip variability issues.
    Kanal E; Shellock FG; Lewin JS
    Radiology; 1996 Aug; 200(2):576-8. PubMed ID: 8685361
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characterization of ferromagnetic or conductive properties of metallic foreign objects embedded within the human body with magnetic iron detector (MID): Screening patients for MRI.
    Gianesin B; Zefiro D; Paparo F; Caminata A; Balocco M; Carrara P; Quintino S; Pinto V; Bacigalupo L; Rollandi GA; Marinelli M; Forni GL
    Magn Reson Med; 2015 May; 73(5):2030-7. PubMed ID: 25820253
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An unexpected ferromagnetic foreign body in a paediatric research participant undergoing 3T MRI.
    Mckinnon K; Jardine C; Barclay G; Thrippleton MJ; Abel S; Wardlaw JM; Bastin ME; Whalley HC; Richardson H; Boardman JP
    BMJ Case Rep; 2024 Jan; 17(1):. PubMed ID: 38272527
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Foreign bodies of external nose and forehead:a case report].
    Jin YL; Jiang X
    Lin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2016 Dec; 30(24):1973-1974. PubMed ID: 29798281
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Detectability of foreign body materials using X-ray, computed tomography and magnetic resonance imaging: A phantom study.
    Voss JO; Doll C; Raguse JD; Beck-Broichsitter B; Walter-Rittel T; Kahn J; Böning G; Maier C; Thieme N
    Eur J Radiol; 2021 Feb; 135():109505. PubMed ID: 33421828
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Unusual nasal foreign body. Hardened concrete as a nasal foreign body].
    Fischer M; Bachor E; Dietrich U; Jahnke K
    HNO; 1998 Jun; 46(6):604-5. PubMed ID: 9677495
    [No Abstract]   [Full Text] [Related]  

  • 17. [Case report: endonasal radiopaque foreign body].
    Froböse N; Köhl A
    Laryngorhinootologie; 2013 Sep; 92(9):610. PubMed ID: 23996552
    [No Abstract]   [Full Text] [Related]  

  • 18. CT detection and location of intraorbital foreign bodies. Experiments with wood and glass.
    Myllylä V; Pyhtinen J; Päivänsalo M; Tervonen O; Koskela P
    Rofo; 1987 Jun; 146(6):639-43. PubMed ID: 3037632
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Diagnosis of foreign bodies in trachea and bronchus of children by means of coronal CT scan].
    Liu J; Zhang W; Yang Z; Xie W
    Lin Chuang Er Bi Yan Hou Ke Za Zhi; 2002 Jun; 16(6):272-3. PubMed ID: 12599775
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Patient screening prior to MR imaging: a practical approach synthesized from protocols at 15 U. S. medical centers.
    Elster AD; Link KM; Carr JJ
    AJR Am J Roentgenol; 1994 Jan; 162(1):195-9. PubMed ID: 8273665
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.