These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

180 related articles for article (PubMed ID: 1564187)

  • 1. Effects of dispersion on the inference of metal texture from S0 plate mode measurements. Part I. Evaluation of dispersion correction methods.
    Li Y; Thompson RB
    J Acoust Soc Am; 1992 Mar; 91(3):1298-309. PubMed ID: 1564187
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The group velocity variation of Lamb wave in fiber reinforced composite plate.
    Rhee SH; Lee JK; Lee JJ
    Ultrasonics; 2007 Dec; 47(1-4):55-63. PubMed ID: 17881029
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Time-frequency analysis of the dispersion of Lamb modes.
    Prosser WH; Seale MD; Smith BT
    J Acoust Soc Am; 1999 May; 105(5):2669-76. PubMed ID: 10335617
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Off-axis propagation of ultrasonic guided waves in thin orthotropic layers: theoretical analysis and dynamic holographic imaging measurement.
    Mukdadi OM; Datta SK; Telschow KL; Deason VA
    IEEE Trans Ultrason Ferroelectr Freq Control; 2001 Nov; 48(6):1581-93. PubMed ID: 11800121
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Analytical study of the propagation of fast longitudinal modes along wz-BN/AlN thin acoustic waveguides.
    Caliendo C
    Sensors (Basel); 2015 Jan; 15(2):2525-37. PubMed ID: 25625904
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The propagation of Lamb waves in a plate bordered with layers of a liquid.
    Wu JR; Zhu ZM
    J Acoust Soc Am; 1992 Feb; 91(2):861-7. PubMed ID: 1556318
    [TBL] [Abstract][Full Text] [Related]  

  • 7. S0 Lamb Mode Scattering Studies in Laminated Composite Plate Structures with Surface Breaking Cracks: Insights into Crack Opening Behavior.
    Gupta S; Rajagopal P
    Ultrasonics; 2023 Mar; 129():106901. PubMed ID: 36473285
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In-plane backward and zero group velocity guided modes in rigid and soft strips.
    Laurent J; Royer D; Prada C
    J Acoust Soc Am; 2020 Feb; 147(2):1302. PubMed ID: 32113319
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Texture in steel plates revealed by laser ultrasonic surface acoustic waves velocity dispersion analysis.
    Yin A; Wang X; Glorieux C; Yang Q; Dong F; He F; Wang Y; Sermeus J; Van der Donck T; Shu X
    Ultrasonics; 2017 Jul; 78():30-39. PubMed ID: 28282636
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Air coupled ultrasonic inspection with Lamb waves in plates showing mode conversion.
    Römmeler A; Zolliker P; Neuenschwander J; van Gemmeren V; Weder M; Dual J
    Ultrasonics; 2020 Jan; 100():105984. PubMed ID: 31479964
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of an advanced multimode automatic ultrasonic texture measurement system for laboratory and production line application.
    Potter MD; Dixon S; Morrison JP; Suliamann AS
    Ultrasonics; 2006 Dec; 44 Suppl 1():e813-7. PubMed ID: 16793085
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Elastic constants measurement of anisotropic Olivier wood plates using air-coupled transducers generated Lamb wave and ultrasonic bulk wave.
    Dahmen S; Ketata H; Ben Ghozlen MH; Hosten B
    Ultrasonics; 2010 Apr; 50(4-5):502-7. PubMed ID: 19962719
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Equivalent boundary conditions for thin orthotropic layer between two solids: reflection, refraction, and interface waves.
    Rokhlin SI; Wang YJ
    J Acoust Soc Am; 1992 Apr; 91(4 Pt 1):1875-87. PubMed ID: 1597594
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Multi-Mode Electromagnetic Ultrasonic Lamb Wave Tomography Imaging for Variable-Depth Defects in Metal Plates.
    Huang S; Zhang Y; Wang S; Zhao W
    Sensors (Basel); 2016 May; 16(5):. PubMed ID: 27144571
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Corrosion and erosion monitoring in plates and pipes using constant group velocity Lamb wave inspection.
    Nagy PB; Simonetti F; Instanes G
    Ultrasonics; 2014 Sep; 54(7):1832-41. PubMed ID: 24582555
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Transmission analysis of ultrasonic Lamb mode conversion in a plate with partial-thickness notch.
    Xu K; Ta D; Su Z; Wang W
    Ultrasonics; 2014 Jan; 54(1):395-401. PubMed ID: 23916666
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Active fiber composites for the generation of Lamb waves.
    Birchmeier M; Gsell D; Juon M; Brunner AJ; Paradies R; Dual J
    Ultrasonics; 2009 Jan; 49(1):73-82. PubMed ID: 18621408
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ultrasonic waves propagation in absorbing thin plates application to paper characterization.
    Bonnin A; Huchon R; Deschamps M
    Ultrasonics; 2000 Jan; 37(8):555-63. PubMed ID: 11243459
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Lift-off compensation for improved accuracy in ultrasonic lamb wave velocity measurements using electromagnetic acoustic transducers (EMATs).
    Morrison JP; Dixon S; Potter MD; Jian X
    Ultrasonics; 2006 Dec; 44 Suppl 1():e1401-4. PubMed ID: 16828139
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Scattering of the fundamental shear horizontal guided wave by a part-thickness crack in an isotropic plate.
    Rajagopal P; Lowe MJ
    J Acoust Soc Am; 2008 Nov; 124(5):2895-2904. PubMed ID: 19045777
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.