These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
24. Effects of the driving condition of a pneumatic ventricular assist device on the cavitation intensity of the inlet and outlet mechanical heart valves. Lee H; Tatsumi E; Taenaka Y ASAIO J; 2009; 55(4):328-34. PubMed ID: 19506466 [TBL] [Abstract][Full Text] [Related]
25. An experimental-computational analysis of MHV cavitation: effects of leaflet squeezing and rebound. Makhijani VB; Yang HQ; Singhal AK; Hwang NH J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S35-44; discussion S44-8. PubMed ID: 8061869 [TBL] [Abstract][Full Text] [Related]
26. The effect of tip angle on cavitation potential during closure of a bileaflet prosthesis model. Zhang P; Yeo JH; Qian P; Hwang NH J Heart Valve Dis; 2007 Jul; 16(4):430-9. PubMed ID: 17702370 [TBL] [Abstract][Full Text] [Related]
27. Study of an acoustic technique to detect cavitation produced by a tilting disc valve. Herman BA; Porter JM; Carey RF J Heart Valve Dis; 1996 Jan; 5(1):90-6. PubMed ID: 8834731 [TBL] [Abstract][Full Text] [Related]
30. The effect of dissolved carbon dioxide on cavitation intensity in mechanical heart valves. Herbertson LH; Manning KB; Reddy V; Fontaine AA; Tarbell JM; Deutsch S J Heart Valve Dis; 2005 Nov; 14(6):835-42. PubMed ID: 16363068 [TBL] [Abstract][Full Text] [Related]
31. Estimation of mechanical heart valve cavitation in a pneumatic ventricular assist device. Lee H; Akagawa E; Homma A; Tsukiya T; Tatsumi E; Taenaka Y J Artif Organs; 2007; 10(3):181-5. PubMed ID: 17846718 [TBL] [Abstract][Full Text] [Related]
32. Observation of cavitation pits on mechanical heart valve surfaces in an artificial heart used in in vitro testing. Lee H; Homma A; Tatsumi E; Taenaka Y J Artif Organs; 2010 Apr; 13(1):17-23. PubMed ID: 20155293 [TBL] [Abstract][Full Text] [Related]
33. Development of squeeze flow in mechanical heart valve: a particle image velocimetry investigation. Zhang P; Yeo JH; Hwang NH ASAIO J; 2006; 52(4):391-7. PubMed ID: 16883118 [TBL] [Abstract][Full Text] [Related]
34. Observation and quantification of cavitation on a mechanical heart valve with an electro-hydraulic total artificial heart. Lee H; Taenaka Y Int J Artif Organs; 2006 Mar; 29(3):303-7. PubMed ID: 16685674 [TBL] [Abstract][Full Text] [Related]
35. Pressure field in the vicinity of mechanical valve occluders at the instant of valve closure: correlation with cavitation initiation. Chandran KB; Lee CS; Chen LD J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S65-75; discussion S75-6. PubMed ID: 8061871 [TBL] [Abstract][Full Text] [Related]
36. Mechanical valve closing dynamics: relationship between velocity of closing, pressure transients, and cavitation initiation. Chandran KB; Aluri S Ann Biomed Eng; 1997; 25(6):926-38. PubMed ID: 9395039 [TBL] [Abstract][Full Text] [Related]
37. Squeeze flow measurements in mechanical heart valves. Lo CW; Lu PC; Liu JS; Li CP; Hwang NH ASAIO J; 2008; 54(2):156-62. PubMed ID: 18356648 [TBL] [Abstract][Full Text] [Related]
38. In vitro observations of mechanical heart valve cavitation. Shu MC; Leuer LH; Armitage TL; Schneider TE; Christiansen DR J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S85-92; discussion S92-3. PubMed ID: 8061874 [TBL] [Abstract][Full Text] [Related]
39. Hydrodynamic characteristics of the Edwards MIRA bileaflet valve in a pneumatic ventricular assist device. Lee H; Taenaka Y ASAIO J; 2007; 53(4):397-402. PubMed ID: 17667221 [TBL] [Abstract][Full Text] [Related]
40. Dependence of tissue valve leaflet motion on the viscosity of blood analogue fluid. Chandran KB; Fatemi R; Schoephoerster R Life Support Syst; 1986; 4(4):289-303. PubMed ID: 3561030 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]