BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

229 related articles for article (PubMed ID: 15651604)

  • 1. An error-reduction-based algorithm for cone-beam computed tomography.
    Zeng K; Chen Z; Zhang L; Wang G
    Med Phys; 2004 Dec; 31(12):3206-12. PubMed ID: 15651604
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A reconstruction algorithm for helical CT imaging on PI-planes.
    Liang H; Zhang C; Yan M
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():2534-7. PubMed ID: 17945720
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development of a cone angle weighted three-dimensional image reconstruction algorithm to reduce cone-beam artefacts.
    Gomi T; Koshida K; Miyati T
    Dentomaxillofac Radiol; 2006 Nov; 35(6):398-406. PubMed ID: 17082329
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A filtered backprojection algorithm for cone beam reconstruction using rotational filtering under helical source trajectory.
    Tang X; Hsieh J
    Med Phys; 2004 Nov; 31(11):2949-60. PubMed ID: 15587646
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Handling data redundancy in helical cone beam reconstruction with a cone-angle-based window function and its asymptotic approximation.
    Tang X; Hsieh J
    Med Phys; 2007 Jun; 34(6):1989-98. PubMed ID: 17654902
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Tilted plane Feldkamp type reconstruction algorithm for spiral cone beam CT.
    Yan M; Zhang C
    Med Phys; 2005 Nov; 32(11):3455-67. PubMed ID: 16370432
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A three-dimensional-weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT-helical scanning.
    Tang X; Hsieh J; Nilsen RA; Dutta S; Samsonov D; Hagiwara A
    Phys Med Biol; 2006 Feb; 51(4):855-74. PubMed ID: 16467583
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fan-beam and cone-beam image reconstruction via filtering the backprojection image of differentiated projection data.
    Zhuang T; Leng S; Nett BE; Chen GH
    Phys Med Biol; 2004 Dec; 49(24):5489-503. PubMed ID: 15724538
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A combination-weighted Feldkamp-based reconstruction algorithm for cone-beam CT.
    Mori S; Endo M; Komatsu S; Kandatsu S; Yashiro T; Baba M
    Phys Med Biol; 2006 Aug; 51(16):3953-65. PubMed ID: 16885617
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A unified analysis of FBP-based algorithms in helical cone-beam and circular cone- and fan-beam scans.
    Pan X; Xia D; Zou Y; Yu L
    Phys Med Biol; 2004 Sep; 49(18):4349-69. PubMed ID: 15509070
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The cone-beam algorithm of Feldkamp, Davis, and Kress preserves oblique line integrals.
    Rodet T; Noo F; Defrise M
    Med Phys; 2004 Jul; 31(7):1972-5. PubMed ID: 15305448
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A general exact reconstruction for cone-beam CT via backprojection-filtration.
    Ye Y; Zhao S; Yu H; Wang G
    IEEE Trans Med Imaging; 2005 Sep; 24(9):1190-8. PubMed ID: 16156356
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cone-beam and fan-beam image reconstruction algorithms based on spherical and circular harmonics.
    Zeng GL; Gullberg GT
    Phys Med Biol; 2004 Jun; 49(11):2239-56. PubMed ID: 15248575
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A new weighting scheme for cone-beam helical CT to reduce the image noise.
    Taguchi K; Chiang BS; Silver MD
    Phys Med Biol; 2004 Jun; 49(11):2351-64. PubMed ID: 15248582
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Image reconstruction for the circle-and-arc trajectory.
    Katsevich A
    Phys Med Biol; 2005 May; 50(10):2249-65. PubMed ID: 15876665
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A Grangeat-type half-scan algorithm for cone-beam CT.
    Lee SW; Wang G
    Med Phys; 2003 Apr; 30(4):689-700. PubMed ID: 12722821
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Spiral scan long object reconstruction through PI line reconstruction.
    Tam KC; Hu J; Sourbelle K
    Phys Med Biol; 2004 Jun; 49(11):2453-62. PubMed ID: 15248589
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reduction of artifacts induced by misaligned geometry in cone-beam CT.
    Sun Y; Hou Y; Hu J
    IEEE Trans Biomed Eng; 2007 Aug; 54(8):1461-71. PubMed ID: 17694867
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Region of interest reconstruction from truncated data in circular cone-beam CT.
    Yu L; Zou Y; Sidky EY; Pelizzari CA; Munro P; Pan X
    IEEE Trans Med Imaging; 2006 Jul; 25(7):869-81. PubMed ID: 16827488
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fully truncated cone-beam reconstruction on Pi lines using prior CT.
    Ramamurthi K; Strobel N; Fahrig R; Prince JL
    Med Image Comput Comput Assist Interv; 2005; 8(Pt 1):631-8. PubMed ID: 16685899
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.