These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
8. Biomechanical analysis of an interspinous fusion device as a stand-alone and as supplemental fixation to posterior expandable interbody cages in the lumbar spine. Gonzalez-Blohm SA; Doulgeris JJ; Aghayev K; Lee WE; Volkov A; Vrionis FD J Neurosurg Spine; 2014 Feb; 20(2):209-19. PubMed ID: 24286528 [TBL] [Abstract][Full Text] [Related]
14. In vitro biomechanical comparison of an anterior and anterolateral lumbar plate with posterior fixation following single-level anterior lumbar interbody fusion. Johnson WM; Nichols TA; Jethwani D; Guiot BH J Neurosurg Spine; 2007 Sep; 7(3):332-5. PubMed ID: 17877269 [TBL] [Abstract][Full Text] [Related]
15. Direct lateral approach to lumbar fusion is a biomechanically equivalent alternative to the anterior approach: an in vitro study. Laws CJ; Coughlin DG; Lotz JC; Serhan HA; Hu SS Spine (Phila Pa 1976); 2012 May; 37(10):819-25. PubMed ID: 21971125 [TBL] [Abstract][Full Text] [Related]
16. Biomechanical evaluation of an expandable cage in single-segment posterior lumbar interbody fusion. Bhatia NN; Lee KH; Bui CN; Luna M; Wahba GM; Lee TQ Spine (Phila Pa 1976); 2012 Jan; 37(2):E79-85. PubMed ID: 21629171 [TBL] [Abstract][Full Text] [Related]
17. Primary stiffness of a modified transforaminal lumbar interbody fusion cage with integrated screw fixation: cadaveric biomechanical study. Keiler A; Schmoelz W; Erhart S; Gnanalingham K Spine (Phila Pa 1976); 2014 Aug; 39(17):E994-E1000. PubMed ID: 24875958 [TBL] [Abstract][Full Text] [Related]
18. Biomechanics of lateral lumbar interbody fusion constructs with lateral and posterior plate fixation: laboratory investigation. Fogel GR; Parikh RD; Ryu SI; Turner AW J Neurosurg Spine; 2014 Mar; 20(3):291-7. PubMed ID: 24405464 [TBL] [Abstract][Full Text] [Related]
19. Augmentation of anterior lumbar interbody fusion with anterior pedicle screw fixation: demonstration of novel constructs and evaluation of biomechanical stability in cadaveric specimens. Karim A; Mukherjee D; Ankem M; Gonzalez-Cruz J; Smith D; Nanda A Neurosurgery; 2006 Mar; 58(3):522-7; discussion 522-7. PubMed ID: 16528193 [TBL] [Abstract][Full Text] [Related]
20. Biomechanical testing of the lumbar facet interference screw. Kandziora F; Schleicher P; Scholz M; Pflugmacher R; Eindorf T; Haas NP; Pavlov PW Spine (Phila Pa 1976); 2005 Jan; 30(2):E34-9. PubMed ID: 15644745 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]