BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 15662773)

  • 1. Computational model for the estimation of the extracranial doses received during Leksell gamma knife model C treatment.
    Majali M; Novotny J; Novotny J
    J Neurosurg; 2005 Jan; 102 Suppl():14-8. PubMed ID: 15662773
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Transportation dose and doses to extracranial sites during stereotactic radiosurgery with the Leksell Gamma knife.
    Novotný J; Novotný J; Hobzová L; Simonová G; Liscák R; Vladyka V
    Stereotact Funct Neurosurg; 1996; 66(4):170-83. PubMed ID: 9144872
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Extracranial radiation doses in patients undergoing gamma knife radiosurgery.
    Yu C; Luxton G; Apuzzo ML; MacPherson DM; Petrovich Z
    Neurosurgery; 1997 Sep; 41(3):553-9; discussion 559-60. PubMed ID: 9310971
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An investigation of eye lens dose of stereotactic radiosurgery for trigeminal neuralgia using Leksell Gamma Knife model C.
    Liang CL; Ho MW; Lu K; Tsai YD; Liliang PC; Wang KW; Chen HJ
    J Neurosurg; 2006 Dec; 105 Suppl():112-6. PubMed ID: 18503342
    [TBL] [Abstract][Full Text] [Related]  

  • 5. MCNP-based computational model for the Leksell gamma knife.
    Trnka J; Novotny J; Kluson J
    Med Phys; 2007 Jan; 34(1):63-75. PubMed ID: 17278491
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Target and peripheral dose during patient repositioning with the Gamma Knife automatic positioning system (APS) device.
    Tran TA; Stanley TR; Malhotra HK; De Boer SF; Prasad D; Podgorsak MB
    J Appl Clin Med Phys; 2010 Jan; 11(1):3150. PubMed ID: 20160701
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Radiosurgery with the world's first fully robotized Leksell Gamma Knife PerfeXion in clinical use: a 200-patient prospective, randomized, controlled comparison with the Gamma Knife 4C.
    Régis J; Tamura M; Guillot C; Yomo S; Muraciolle X; Nagaje M; Arka Y; Porcheron D
    Neurosurgery; 2009 Feb; 64(2):346-55; discussion 355-6. PubMed ID: 19190462
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of absorbed dose to thyroid, parotid and ovaries in patients undergoing Gamma Knife radiosurgery.
    Hasanzadeh H; Sharafi A; Allah Verdi M; Nikoofar A
    Phys Med Biol; 2006 Sep; 51(17):4375-83. PubMed ID: 16912387
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Verification of dose profiles generated by the convolution algorithm of the gamma knife
    Chung HT; Park JH; Chun KJ
    Med Phys; 2017 Sep; 44(9):4880-4889. PubMed ID: 28513854
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Whole body radiation exposure with gamma unit radiosurgery.
    Chao MM; Lee YL; Chao LS; Yen SH; Chung WY; Pan DH; Chen KY
    Zhonghua Yi Xue Za Zhi (Taipei); 1996 Jul; 58(1):29-34. PubMed ID: 8870324
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Extracranial absorbed doses with Gamma Knife radiosurgery.
    Berk HW; Larner JM; Spaulding C; Agarwal SK; Scott MR; Steiner L
    Stereotact Funct Neurosurg; 1993; 61 Suppl 1():164-72. PubMed ID: 8115748
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fetal radiation doses for model C gamma knife radiosurgery.
    Yu C; Jozsef G; Apuzzo ML; MacPherson DM; Petrovich Z
    Neurosurgery; 2003 Mar; 52(3):687-93; discussion 693. PubMed ID: 12590695
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Monte Carlo calculations and GafChromic film measurements for plugged collimator helmets of Leksell Gamma Knife unit.
    Cheung JY; Yu KN; Ho RT; Yu CP
    Med Phys; 1999 Jul; 26(7):1252-6. PubMed ID: 10435525
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The Leksell Gamma Knife Perfexion and comparisons with its predecessors.
    Lindquist C; Paddick I
    Neurosurgery; 2007 Sep; 61(3 Suppl):130-40; discussion 140-1. PubMed ID: 17876243
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Gamma Knife radiosurgery with CT image-based dose calculation.
    Xu AY; Bhatnagar J; Bednarz G; Niranjan A; Kondziolka D; Flickinger J; Lunsford LD; Huq MS
    J Appl Clin Med Phys; 2015 Nov; 16(6):119–129. PubMed ID: 26699563
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of radiation dose spillage from the Gamma Knife Perfexion with that from volumetric modulated arc radiosurgery during treatment of multiple brain metastases in a single fraction.
    McDonald D; Schuler J; Takacs I; Peng J; Jenrette J; Vanek K
    J Neurosurg; 2014 Dec; 121 Suppl():51-9. PubMed ID: 25434937
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Mechanical and dose delivery accuracy evaluation in radiosurgery using polymer gels.
    Sandilos P; Tatsis E; Vlachos L; Karaiskos P; Georgiou E; Kipouros P; Torrens M; Angelopoulos A
    J Appl Clin Med Phys; 2006 Nov; 7(4):13-21. PubMed ID: 17533353
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Gamma knife surgery for trigeminal neuralgia: improved initial response with two isocenters and increasing dose.
    Alpert TE; Chung CT; Mitchell LT; Hodge CJ; Montgomery CT; Bogart JA; Kim DY; Bassano DA; Hahn SS
    J Neurosurg; 2005 Jan; 102 Suppl():185-8. PubMed ID: 15662807
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Verification of source and collimator configuration for Gamma Knife Perfexion using panoramic imaging.
    Cho YB; van Prooijen M; Jaffray DA; Islam MK
    Med Phys; 2010 Mar; 37(3):1325-31. PubMed ID: 20384269
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Two-year experience with the commercial Gamma Knife Check software.
    Xu AY; Bhatnagar J; Bednarz G; Novotny J; Flickinger J; Lunsford LD; Huq MS
    J Appl Clin Med Phys; 2016 Jul; 17(4):95-105. PubMed ID: 27455470
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.