BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 15664588)

  • 1. Septic arthritis of the major joints of the lower limb after periarticular external fixation application: are conventional safe corridors enough to prevent it?
    Stavlas P; Polyzois D
    Injury; 2005 Feb; 36(2):239-47. PubMed ID: 15664588
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Complications encountered while using thin-wire-hybrid-external fixation modular frames for fracture fixation. A retrospective clinical analysis and possible support for "Damage Control Orthopaedic Surgery".
    Lerner A; Chezar A; Haddad M; Kaufman H; Rozen N; Stein H
    Injury; 2005 May; 36(5):590-8. PubMed ID: 15826616
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effect of knee-spanning external fixation on compartment pressures in the leg.
    Egol KA; Bazzi J; McLaurin TM; Tejwani NC
    J Orthop Trauma; 2008; 22(10):680-5. PubMed ID: 18978542
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Soft tissue injuries with the use of safe corridors for transfixion wire placement during external fixation of distal tibia fractures: an anatomic study.
    Vives MJ; Abidi NA; Ishikawa SN; Taliwal RV; Sharkey PF
    J Orthop Trauma; 2001 Nov; 15(8):555-9. PubMed ID: 11733671
    [TBL] [Abstract][Full Text] [Related]  

  • 5. External fixation and pseudoaneurysm: report of a case related to tibial lengthening.
    Papanikolaou A; Thanassas C; Arealis G; Maris J
    Orthopedics; 2008 Oct; 31(10):. PubMed ID: 19225998
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cadaveric analysis of capsular attachments of the distal femur related to pin and wire placement.
    Lowery K; Dearden P; Sherman K; Mahadevan V; Sharma H
    Injury; 2015; 46(6):970-4. PubMed ID: 25835529
    [TBL] [Abstract][Full Text] [Related]  

  • 7. External fixation of tibial pilon fractures and fracture healing.
    Ristiniemi J
    Acta Orthop Suppl; 2007 Jun; 78(326):3, 5-34. PubMed ID: 17465283
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pin and wire technique for external fixation.
    Green SA
    Instr Course Lect; 1995; 44():487-93. PubMed ID: 7797887
    [No Abstract]   [Full Text] [Related]  

  • 9. [Pedicle flap transfer combined with external fixator to treat leg open fracture with soft tissue defect].
    Luo Z; Lou H; Jiang J; Song C; Gong M; Wang Y
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Aug; 22(8):956-8. PubMed ID: 18773813
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Safe corridors for external skeletal fixator pin placement in feline long bones.
    Prackova I; Paral V; Kyllar M
    J Feline Med Surg; 2022 Oct; 24(10):1008-1016. PubMed ID: 34870491
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Septic knee from Ilizarov transfixation tibial pin.
    Stevens MA; DeCoster TA; Garcia F; Sell JJ
    Iowa Orthop J; 1995; 15():217-20. PubMed ID: 7634036
    [No Abstract]   [Full Text] [Related]  

  • 12. Treatment strategies for complex fractures of the tibial plateau with external circular fixation and limited internal fixation.
    Catagni MA; Ottaviani G; Maggioni M
    J Trauma; 2007 Nov; 63(5):1043-53. PubMed ID: 17993949
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intramedullary nailing of proximal and distal one-third tibial shaft fractures with intraoperative two-pin external fixation.
    Wysocki RW; Kapotas JS; Virkus WW
    J Trauma; 2009 Apr; 66(4):1135-9. PubMed ID: 19359926
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pin tract infection with external fixation of pediatric fractures.
    Schalamon J; Petnehazy T; Ainoedhofer H; Zwick EB; Singer G; Hoellwarth ME
    J Pediatr Surg; 2007 Sep; 42(9):1584-7. PubMed ID: 17848253
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The 'Retro-Fibular Wire': an anatomical study describing a safe corridor for placement of fine wires in the distal tibia.
    Loughenbury PR; Harwood PJ; Tunstall R; Britten S
    J Bone Joint Surg Br; 2010 Jul; 92(7):1041-4. PubMed ID: 20595130
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Parotid salivary fistula secondary to external pin fixation: case report.
    Levine CL; Berger JR; Lazow SK
    J Craniomaxillofac Trauma; 1996; 2(4):20-3. PubMed ID: 11951445
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Functional outcome of tibial plateau fractures treated with the fine-wire fixator.
    Chin TY; Bardana D; Bailey M; Williamson OD; Miller R; Edwards ER; Esser MP
    Injury; 2005 Dec; 36(12):1467-75. PubMed ID: 16243333
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Infections in periarticular fractures of the lower extremity treated with tensioned wire hybrid fixators.
    Hutson JJ; Zych GA
    J Orthop Trauma; 1998; 12(3):214-8. PubMed ID: 9553864
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The basics of ring external fixator application and care.
    Beaman DN; Gellman R
    Foot Ankle Clin; 2008 Mar; 13(1):15-27,v. PubMed ID: 18328414
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fractures of the distal radius treated with a nonbridging external fixation technique using multiplanar k-wires.
    Gradl G; Jupiter JB; Gierer P; Mittlmeier T
    J Hand Surg Am; 2005 Sep; 30(5):960-8. PubMed ID: 16182052
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.