BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

224 related articles for article (PubMed ID: 15665046)

  • 1. Poor agreement among prothrombin time international normalized ratio methods: comparison of seven commercial reagents.
    Horsti J; Uppa H; Vilpo JA
    Clin Chem; 2005 Mar; 51(3):553-60. PubMed ID: 15665046
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Discrepant sensitivity of thromboplastin reagents to clotting factor levels explored by the prothrombin time in patients on stable oral anticoagulant treatment: impact on the international normalized ratio system.
    Testa S; Morstabilini G; Fattorini A; Galli L; Denti N; D'Angelo A
    Haematologica; 2002 Dec; 87(12):1265-73. PubMed ID: 12495900
    [TBL] [Abstract][Full Text] [Related]  

  • 3. International collaborative study for the calibration of proposed International Standards for thromboplastin, rabbit, plain, and for thromboplastin, recombinant, human, plain.
    van den Besselaar AMHP; Chantarangkul V; Angeloni F; Binder NB; Byrne M; Dauer R; Gudmundsdottir BR; Jespersen J; Kitchen S; Legnani C; Lindahl TL; Manning RA; Martinuzzo M; Panes O; Pengo V; Riddell A; Subramanian S; Szederjesi A; Tantanate C; Herbel P; Tripodi A
    J Thromb Haemost; 2018 Jan; 16(1):142-149. PubMed ID: 29065247
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The prothrombin time/international normalized ratio (PT/INR) Line: derivation of local INR with commercial thromboplastins and coagulometers--two independent studies.
    Poller L; Ibrahim S; Keown M; Pattison A; Jespersen J;
    J Thromb Haemost; 2011 Jan; 9(1):140-8. PubMed ID: 20942851
    [TBL] [Abstract][Full Text] [Related]  

  • 5. INR derivation with the PT/INR Line simplified using a spreadsheet from the world wide web.
    Poller L; Ibrahim S; Pattison A; Jespersen J;
    J Clin Pathol; 2011 Oct; 64(10):930-2. PubMed ID: 21515693
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Has the time arrived to replace the quick prothrombin time test for monitoring oral anticoagulant therapy?
    Jackson CM; Esnouf MP
    Clin Chem; 2005 Mar; 51(3):483-5. PubMed ID: 15738512
    [No Abstract]   [Full Text] [Related]  

  • 7. Harmonizing the International Normalized Ratio (INR) : Standardization of Methods and Use of Novel Strategies to Reduce Interlaboratory Variation and Bias.
    Favaloro EJ; McVicker W; Lay M; Ahuja M; Zhang Y; Hamdam S; Hocker N
    Am J Clin Pathol; 2016 Feb; 145(2):191-202. PubMed ID: 26800763
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Point-of-care monitoring of oral anticoagulation therapy in children. Comparison of the CoaguChek XS system with venous INR and venous INR using an International Reference Thromboplastin preparation (rTF/95).
    Greenway A; Ignjatovic V; Summerhayes R; Newall F; Burgess J; DeRosa L; Monagle P
    Thromb Haemost; 2009 Jul; 102(1):159-65. PubMed ID: 19572081
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quality assurance program for whole blood prothrombin time-international normalized ratio point-of-care monitors used for patient self-testing to control oral anticoagulation.
    Tripodi A; Bressi C; Carpenedo M; Chantarangkul V; Clerici M; Mannucci PM
    Thromb Res; 2004; 113(1):35-40. PubMed ID: 15081563
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Improving the inter-laboratory harmonization of the international normalized ratio (INR): utilizing the concept of transference to estimate and/or validate international sensitivity index (ISI) and mean normal prothrombin time (MNPT) values and/or to eliminate measurement bias.
    Favaloro EJ; McVicker W; Zhang Y; Hamdam S; Huynh M; Peris P; O'Neal M; Hocker N
    Clin Lab Sci; 2012; 25(1):13-25. PubMed ID: 22458045
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparison of INRs determined with a whole blood prothrombin time device and two international reference preparations for thromboplastin.
    van den Besselaar AM
    Thromb Haemost; 2000 Sep; 84(3):410-2. PubMed ID: 11019963
    [TBL] [Abstract][Full Text] [Related]  

  • 12. INR calibration of Owren-type prothrombin time based on the relationship between PT% and INR utilizing normal plasma samples.
    Lindahl TL; Egberg N; Hillarp A; Ødegaard OR; Edlund B; Svensson J; Sandset PM; Rånby M
    Thromb Haemost; 2004 Jun; 91(6):1223-31. PubMed ID: 15175811
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A modified international normalized ratio as an effective way of prothrombin time standardization in hepatology.
    Bellest L; Eschwège V; Poupon R; Chazouillères O; Robert A
    Hepatology; 2007 Aug; 46(2):528-34. PubMed ID: 17654598
    [TBL] [Abstract][Full Text] [Related]  

  • 14. European Concerted Action on Anticoagulation. Correction of displayed international normalized ratio on two point-of-care test whole-blood prothrombin time monitors (CoaguChek Mini and TAS PT-NC) by independent international sensitivity index calibration.
    Poller L; Keown M; Chauhan N; Van Den Besselaar AM; Tripodi A; Shiach C; Jespersen J;
    Br J Haematol; 2003 Sep; 122(6):944-9. PubMed ID: 12956765
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An International Sensitivity Index (ISI) derived from patients with abnormal liver function improves agreement between INRs determined with different reagents.
    Sermon AM; Smith JM; Maclean R; Kitchen S
    Thromb Haemost; 2010 Apr; 103(4):757-65. PubMed ID: 20174759
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Oral anticoagulant monitoring by laboratory or near-patient testing: what a clinician should be aware of.
    Tripodi A; Breukink-Engbers WG; van den Besselaar AM
    Semin Vasc Med; 2003 Aug; 3(3):243-54. PubMed ID: 15199457
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Field study of lyophilized calibrant plasmas for fresh plasma INR determination.
    van den Besselaar AM; Houbouyan-Réveillard LL
    Thromb Haemost; 2002 Feb; 87(2):277-81. PubMed ID: 11859852
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An international collaborative study on the INR calibration of freeze-dried reference plasmas.
    Hubbard AR; Margetts SM; Weller LJ; Macnab J; Barrowcliffe TW
    Br J Haematol; 1999 Mar; 104(3):455-60. PubMed ID: 10086778
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improving the harmonisation of the International Normalized Ratio (INR): time to think outside the box?
    Favaloro EJ; McVicker W; Hamdam S; Hocker N
    Clin Chem Lab Med; 2010 Aug; 48(8):1079-90. PubMed ID: 20441474
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Standardization of coagulation tests.
    Opartkiattikul N
    Southeast Asian J Trop Med Public Health; 1999; 30 Suppl 3():79-85. PubMed ID: 10926265
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.