BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

387 related articles for article (PubMed ID: 15668576)

  • 1. Surgical treatment of intertrochanteric hip fractures with associated femoral neck fractures using a sliding hip screw.
    Kyle RF; Ellis TJ; Templeman DC
    J Orthop Trauma; 2005 Jan; 19(1):1-4. PubMed ID: 15668576
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Is tip apex distance as important as we think? A biomechanical study examining optimal lag screw placement.
    Kane P; Vopat B; Heard W; Thakur N; Paller D; Koruprolu S; Born C
    Clin Orthop Relat Res; 2014 Aug; 472(8):2492-8. PubMed ID: 24760583
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Reliability of predictors for screw cutout in intertrochanteric hip fractures.
    De Bruijn K; den Hartog D; Tuinebreijer W; Roukema G
    J Bone Joint Surg Am; 2012 Jul; 94(14):1266-72. PubMed ID: 22810396
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Outcomes of dynamic hip screw augmented with trochanteric wiring for treatment of unstable type A2 intertrochanteric femur fractures.
    Puram C; Pradhan C; Patil A; Sodhai V; Sancheti P; Shyam A
    Injury; 2017 Aug; 48 Suppl 2():S72-S77. PubMed ID: 28802425
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The trochanteric nail versus the sliding hip screw for intertrochanteric hip fractures: a review of 93 cases.
    Crawford CH; Malkani AL; Cordray S; Roberts CS; Sligar W
    J Trauma; 2006 Feb; 60(2):325-8; discussion 328-9. PubMed ID: 16508490
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Risk factors in cutout of sliding hip screw in intertrochanteric fractures: an evaluation of 937 patients.
    Hsueh KK; Fang CK; Chen CM; Su YP; Wu HF; Chiu FY
    Int Orthop; 2010 Dec; 34(8):1273-6. PubMed ID: 19784649
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Anterior Malreduction is Associated With Lag Screw Cutout After Internal Fixation of Intertrochanteric Fractures.
    Inui T; Watanabe Y; Suzuki T; Matsui K; Kurata Y; Ishii K; Kurozumi T; Kawano H
    Clin Orthop Relat Res; 2024 Mar; 482(3):536-545. PubMed ID: 37732692
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Conversion to total hip arthroplasty after failed proximal femoral nail antirotations or dynamic hip screw fixations for stable intertrochanteric femur fractures: a retrospective study with a minimum follow-up of 3 years.
    Zeng X; Zhan K; Zhang L; Zeng D; Yu W; Zhang X; Zhao M
    BMC Musculoskelet Disord; 2017 Jan; 18(1):38. PubMed ID: 28122548
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Treatment of cutout of a lag screw of a dynamic hip screw in an intertrochanteric fracture.
    Wu CC; Shih CH; Chen WJ; Tai CL
    Arch Orthop Trauma Surg; 1998; 117(4-5):193-6. PubMed ID: 9581243
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Radiographic and functional results of osteosynthesis using the proximal femoral nail antirotation (PFNA) in the treatment of unstable intertrochanteric femoral fractures.
    Sahin S; Ertürer E; Oztürk I; Toker S; Seçkin F; Akman S
    Acta Orthop Traumatol Turc; 2010; 44(2):127-34. PubMed ID: 20676015
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Helical blade vs telescoping lag screw for intertrochanteric fracture fixation.
    Schwarzkopf R; Takemoto RC; Kummer FJ; Egol KA
    Am J Orthop (Belle Mead NJ); 2011 Sep; 40(9):452-6. PubMed ID: 22022674
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Risk factors for cut-out of double lag screw fixation in proximal femoral fractures.
    Buyukdogan K; Caglar O; Isik S; Tokgozoglu M; Atilla B
    Injury; 2017 Feb; 48(2):414-418. PubMed ID: 27889112
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Importance of screw position in intertrochanteric femoral fractures treated by dynamic hip screw.
    Güven M; Yavuz U; Kadioğlu B; Akman B; Kilinçoğlu V; Unay K; Altintaş F
    Orthop Traumatol Surg Res; 2010 Feb; 96(1):21-7. PubMed ID: 20170854
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reverse obliquity fractures of the intertrochanteric region of the femur.
    Haidukewych GJ; Israel TA; Berry DJ
    J Bone Joint Surg Am; 2001 May; 83(5):643-50. PubMed ID: 11379732
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Failure Patterns of Femoral Neck Fracture Fixation in Young Patients.
    Stockton DJ; Dua K; O'Brien PJ; Pollak AN; Hoshino CM; Slobogean GP
    Orthopedics; 2019 Jul; 42(4):e376-e380. PubMed ID: 30913299
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Factors influencing functional outcomes in united intertrochanteric hip fractures: a negative effect of lag screw sliding.
    Yoo JH; Kim TY; Chang JD; Kwak YH; Kwon YS
    Orthopedics; 2014 Dec; 37(12):e1101-7. PubMed ID: 25437085
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Sliding Hip Screw and Side Plate for Intertrochanteric Hip Fractures.
    Shih Y; Bartschat NI; Cheng EY
    JBJS Essent Surg Tech; 2022; 12(1):. PubMed ID: 35685237
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Alternative techniques in trochanteric hip fracture surgery. Clinical and biomechanical studies on the Medoff sliding plate and the Twin hook.
    Olsson O
    Acta Orthop Scand Suppl; 2000 Oct; 295():1-31. PubMed ID: 11116961
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Additional fixations for sliding hip screws in treating unstable pertrochanteric femoral fractures (AO Type 31-A2): short-term clinical results.
    Cho SH; Lee SH; Cho HL; Ku JH; Choi JH; Lee AJ
    Clin Orthop Surg; 2011 Jun; 3(2):107-13. PubMed ID: 21629470
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A mathematical simulation of the tip-apex distance and the calcar-referenced tip-apex distance for intertrochanteric fractures reduced with lag screws.
    Li S; Chang SM; Jin YM; Zhang YQ; Niu WX; Du SC; Zhang LZ; Ma H
    Injury; 2016 Jun; 47(6):1302-8. PubMed ID: 27087281
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.