These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

303 related articles for article (PubMed ID: 15675001)

  • 1. Across- and within-channel envelope interactions in cochlear implant listeners.
    Chatterjee M; Oba SI
    J Assoc Res Otolaryngol; 2004 Dec; 5(4):360-75. PubMed ID: 15675001
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Modulation masking in cochlear implant listeners: envelope versus tonotopic components.
    Chatterjee M
    J Acoust Soc Am; 2003 Apr; 113(4 Pt 1):2042-53. PubMed ID: 12703715
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Modulation detection interference in cochlear implant listeners under forward masking conditions.
    Chatterjee M; Kulkarni AM
    J Acoust Soc Am; 2018 Feb; 143(2):1117. PubMed ID: 29495705
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comodulation masking release (CMR) as a function of masker bandwidth, modulator bandwidth, and signal duration.
    Schooneveldt GP; Moore BC
    J Acoust Soc Am; 1989 Jan; 85(1):273-81. PubMed ID: 2921409
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Binaural modulation masking.
    Grantham DW; Bacon SP
    J Acoust Soc Am; 1991 Mar; 89(3):1340-9. PubMed ID: 2030221
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Factors affecting thresholds for sinusoidal signals in narrow-band maskers with fluctuating envelopes.
    Moore BC; Glasberg BR
    J Acoust Soc Am; 1987 Jul; 82(1):69-79. PubMed ID: 3624643
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Across-channel masking and comodulation masking release.
    Moore BC; Glasberg BR; Schooneveldt GP
    J Acoust Soc Am; 1990 Apr; 87(4):1683-94. PubMed ID: 2341672
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Understanding speech in modulated interference: cochlear implant users and normal-hearing listeners.
    Nelson PB; Jin SH; Carney AE; Nelson DA
    J Acoust Soc Am; 2003 Feb; 113(2):961-8. PubMed ID: 12597189
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comodulation detection differences for fixed-frequency and roved-frequency maskers.
    Hall JW; Buss E; Grose JH
    J Acoust Soc Am; 2006 Feb; 119(2):1021-8. PubMed ID: 16521764
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Forward-masking patterns produced by symmetric and asymmetric pulse shapes in electric hearing.
    Macherey O; van Wieringen A; Carlyon RP; Dhooge I; Wouters J
    J Acoust Soc Am; 2010 Jan; 127(1):326-38. PubMed ID: 20058980
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Modulation detection interference in cochlear implant subjects.
    Richardson LM; Busby PA; Clark GM
    J Acoust Soc Am; 1998 Jul; 104(1):442-52. PubMed ID: 9670536
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comodulation masking release using SAM tonal complex maskers: effects of modulation depth and signal position.
    Grose JH; Hall JW
    J Acoust Soc Am; 1989 Mar; 85(3):1276-84. PubMed ID: 2708670
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Electric-acoustic forward masking in cochlear implant users with ipsilateral residual hearing.
    Imsiecke M; Krüger B; Büchner A; Lenarz T; Nogueira W
    Hear Res; 2018 Jul; 364():25-37. PubMed ID: 29673567
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of inherent envelope fluctuations in forward maskers for listeners with normal and impaired hearing.
    Svec A; Dubno JR; Nelson PB
    J Acoust Soc Am; 2015 Mar; 137(3):1336-43. PubMed ID: 25786946
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A masking level difference due to harmonicity.
    Treurniet WC; Boucher DR
    J Acoust Soc Am; 2001 Jan; 109(1):306-20. PubMed ID: 11206159
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The relative role of beats and combination tones in determining the shapes of masking patterns: II. Hearing-impaired listeners.
    Alcántara JI; Moore BC
    Hear Res; 2002 Mar; 165(1-2):103-16. PubMed ID: 12031520
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Spatial and temporal disparity in signals and maskers affects signal detection in non-human primates.
    Rocchi F; Dylla ME; Bohlen PA; Ramachandran R
    Hear Res; 2017 Feb; 344():1-12. PubMed ID: 27770624
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Signal detection in temporally modulated and spectrally shaped maskers.
    van den Brink WA; Houtgast T; Smoorenburg GF
    J Acoust Soc Am; 1992 Jan; 91(1):267-78. PubMed ID: 1737877
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Modulation masking: effects of modulation frequency, depth, and phase.
    Bacon SP; Grantham DW
    J Acoust Soc Am; 1989 Jun; 85(6):2575-80. PubMed ID: 2745880
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Speech recognition in noise: estimating effects of compressive nonlinearities in the basilar-membrane response.
    Horwitz AR; Ahlstrom JB; Dubno JR
    Ear Hear; 2007 Sep; 28(5):682-93. PubMed ID: 17804982
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.