These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 15675515)

  • 1. Optimization of an interface chip for coupling capillary electrophoresis with thermal lens microscopic detection.
    Uchiyama K; Tokeshi M; Kikutani Y; Hattori A; Kitamori T
    Anal Sci; 2005 Jan; 21(1):49-52. PubMed ID: 15675515
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An interface chip connection between capillary electrophoresis and thermal lens microscope.
    Uchiyama K; Hibara A; Sato K; Hisamoto H; Tokeshi M; Kitamori T
    Electrophoresis; 2003 Jan; 24(1-2):179-84. PubMed ID: 12652589
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Toward million-fold sensitivity enhancement by sweeping in capillary electrophoresis combined with thermal lens microscopic detection using an interface chip.
    Kitagawa F; Tsuneka T; Akimoto Y; Sueyoshi K; Uchiyama K; Hattori A; Otsuka K
    J Chromatogr A; 2006 Feb; 1106(1-2):36-42. PubMed ID: 16443450
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Chip-CE/MS using a flat low-sheath-flow interface.
    Li FA; Huang JL; Her GR
    Electrophoresis; 2008 Dec; 29(24):4938-43. PubMed ID: 19130573
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Microchip capillary electrophoresis with amperometric detection for rapid separation and detection of seleno amino acids.
    Wang J; Mannino S; Camera C; Chatrathi MP; Scampicchio M; Zima J
    J Chromatogr A; 2005 Oct; 1091(1-2):177-82. PubMed ID: 16395808
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Multichannel microchip electrophoresis device fabricated in polycarbonate with an integrated contact conductivity sensor array.
    Shadpour H; Hupert ML; Patterson D; Liu C; Galloway M; Stryjewski W; Goettert J; Soper SA
    Anal Chem; 2007 Feb; 79(3):870-8. PubMed ID: 17263312
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Microchip CE analysis of amino acids on a titanium dioxide nanoparticles-coated PDMS microfluidic device with in-channel indirect amperometric detection.
    Qiu JD; Wang L; Liang RP; Wang JW
    Electrophoresis; 2009 Oct; 30(19):3472-9. PubMed ID: 19757433
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Microchip Electrophoresis Tools for the Analysis of Small Molecules.
    Gomez FJV; Silva MF
    Methods Mol Biol; 2019; 1906():197-206. PubMed ID: 30488394
    [TBL] [Abstract][Full Text] [Related]  

  • 9. On-chip pumping for pressure mobilization of the focused zones following microchip isoelectric focusing.
    Guillo C; Karlinsey JM; Landers JP
    Lab Chip; 2007 Jan; 7(1):112-8. PubMed ID: 17180213
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Chiral separation of NBD-amino acids by ligand-exchange micro-channel electrophoresis.
    Nakajima H; Kawata K; Shen H; Nakagama T; Uchiyama K
    Anal Sci; 2005 Jan; 21(1):67-71. PubMed ID: 15675519
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of a Microchip CE-HPMS Platform for Cell Growth Monitoring.
    Gilliland WM; Ramsey JM
    Anal Chem; 2018 Nov; 90(21):13000-13006. PubMed ID: 30335366
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fully microfabricated and integrated SU-8-based capillary electrophoresis-electrospray ionization microchips for mass spectrometry.
    Sikanen T; Tuomikoski S; Ketola RA; Kostiainen R; Franssila S; Kotiaho T
    Anal Chem; 2007 Dec; 79(23):9135-44. PubMed ID: 17973354
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Microfluidic chip capillary electrophoresis coupled with electrochemiluminescence for enantioseparation of racemic drugs using central composite design optimization.
    Guo WP; Rong ZB; Li YH; Fung YS; Gao GQ; Cai ZM
    Electrophoresis; 2013 Nov; 34(20-21):2962-9. PubMed ID: 24037989
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An on-column fracture/end-column reaction interface for chemiluminescence detection in capillary electrophoresis.
    Xu Q; Ji X; Li H; Liu J; He Z
    J Chromatogr A; 2010 Aug; 1217(35):5628-34. PubMed ID: 20663507
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A miniaturized liquid core waveguide-capillary electrophoresis system with flow injection sample introduction and fluorometric detection using light-emitting diodes.
    Wang SL; Huang XJ; Fang ZL
    Anal Chem; 2001 Sep; 73(18):4545-9. PubMed ID: 11575805
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A sheathless poly(methyl methacrylate) chip-CE/MS interface fabricated using a wire-assisted epoxy-fixing method.
    Li FA; Wang CH; Her GR
    Electrophoresis; 2007 Apr; 28(8):1265-73. PubMed ID: 17366484
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fabrication of a monolithic sampling probe system for automated and continuous sample introduction in microchip-based CE.
    He QH; Fang Q; Du WB; Fang ZL
    Electrophoresis; 2007 Aug; 28(16):2912-9. PubMed ID: 17640089
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Capillary zone electrophoresis of amino acids on a hybrid poly(dimethylsiloxane)-glass chip.
    Mourzina Y; Steffen A; Kalyagin D; Carius R; Offenhäusser A
    Electrophoresis; 2005 May; 26(9):1849-60. PubMed ID: 15719361
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Multichannel capillary electrophoresis microdevice and instrumentation for in situ planetary analysis of organic molecules and biomarkers.
    Benhabib M; Chiesl TN; Stockton AM; Scherer JR; Mathies RA
    Anal Chem; 2010 Mar; 82(6):2372-9. PubMed ID: 20151682
    [TBL] [Abstract][Full Text] [Related]  

  • 20. High-speed separation and detection of amino acids in laver using a short capillary electrophoresis system.
    Wang W; Ma L; Yao F; Lin X; Xu K
    Electrophoresis; 2015 Jan; 36(2):335-40. PubMed ID: 25223519
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.