80 related articles for article (PubMed ID: 15678533)
1. Real-time display of artifact-free electroencephalography during functional magnetic resonance imaging and magnetic resonance spectroscopy in an animal model of epilepsy.
Mirsattari SM; Ives JR; Bihari F; Leung LS; Menon RS; Bartha R
Magn Reson Med; 2005 Feb; 53(2):456-64. PubMed ID: 15678533
[TBL] [Abstract][Full Text] [Related]
2. Online Reduction of Artifacts in EEG of Simultaneous EEG-fMRI Using Reference Layer Adaptive Filtering (RLAF).
Steyrl D; Krausz G; Koschutnig K; Edlinger G; Müller-Putz GR
Brain Topogr; 2018 Jan; 31(1):129-149. PubMed ID: 29124547
[TBL] [Abstract][Full Text] [Related]
3. An EEG (electroencephalogram) recording system with carbon wire electrodes for simultaneous EEG-fMRI (functional magnetic resonance imaging) recording.
Negishi M; Abildgaard M; Laufer I; Nixon T; Constable RT
J Neurosci Methods; 2008 Aug; 173(1):99-107. PubMed ID: 18588913
[TBL] [Abstract][Full Text] [Related]
4. ICA decomposition of EEG signal for fMRI processing in epilepsy.
Marques JP; Rebola J; Figueiredo P; Pinto A; Sales F; Castelo-Branco M
Hum Brain Mapp; 2009 Sep; 30(9):2986-96. PubMed ID: 19172633
[TBL] [Abstract][Full Text] [Related]
5. Integration of EEG/MEG with MRI and fMRI.
Liu Z; Ding L; He B
IEEE Eng Med Biol Mag; 2006; 25(4):46-53. PubMed ID: 16898658
[TBL] [Abstract][Full Text] [Related]
6. NeuXus open-source tool for real-time artifact reduction in simultaneous EEG-fMRI.
Caetano G; Esteves I; Vourvopoulos A; Fleury M; Figueiredo P
Neuroimage; 2023 Oct; 280():120353. PubMed ID: 37652114
[TBL] [Abstract][Full Text] [Related]
7. Aluminum Thin Film Nanostructure Traces in Pediatric EEG Net for MRI and CT Artifact Reduction.
Jeong H; Ntolkeras G; Warbrick T; Jaschke M; Gupta R; Lev MH; Peters JM; Grant PE; Bonmassar G
Sensors (Basel); 2023 Mar; 23(7):. PubMed ID: 37050693
[TBL] [Abstract][Full Text] [Related]
8. MR imaging-compatible electroencephalography electrode system for an epilepsy monitoring unit.
Mirsattari SM; Tapsell LM; Ives JR; Lee DH
AJNR Am J Neuroradiol; 2008 Oct; 29(9):1649-51. PubMed ID: 18566007
[TBL] [Abstract][Full Text] [Related]
9. Simultaneous fMRI and local field potential measurements during epileptic seizures in medetomidine-sedated rats using raser pulse sequence.
Airaksinen AM; Niskanen JP; Chamberlain R; Huttunen JK; Nissinen J; Garwood M; Pitkänen A; Gröhn O
Magn Reson Med; 2010 Oct; 64(4):1191-9. PubMed ID: 20725933
[TBL] [Abstract][Full Text] [Related]
10. Numerical estimation of the B1 transmit field distortion in a copper EEG trace comparison with the thin-film based resistive trace "NeoNet".
Jeong H; Bonmassar G
Annu Int Conf IEEE Eng Med Biol Soc; 2021 Nov; 2021():4099-4103. PubMed ID: 34892129
[TBL] [Abstract][Full Text] [Related]
11. Movement Artifact Suppression in Wearable Low-Density and Dry EEG Recordings Using Active Electrodes and Artifact Subspace Reconstruction.
Yang SY; Lin YP
IEEE Trans Neural Syst Rehabil Eng; 2023; 31():3844-3853. PubMed ID: 37751338
[TBL] [Abstract][Full Text] [Related]
12. Windows on the human body--in vivo high-field magnetic resonance research and applications in medicine and psychology.
Moser E; Meyerspeer M; Fischmeister FP; Grabner G; Bauer H; Trattnig S
Sensors (Basel); 2010; 10(6):5724-57. PubMed ID: 22219684
[TBL] [Abstract][Full Text] [Related]
13. Simultaneous EEG-fMRI for Functional Neurological Assessment.
Mele G; Cavaliere C; Alfano V; Orsini M; Salvatore M; Aiello M
Front Neurol; 2019; 10():848. PubMed ID: 31456735
[TBL] [Abstract][Full Text] [Related]
14. Protocol for Reducing COVID-19 Transmission Risk in EEG Research.
Simmons AM; Luck SJ
Res Sq; 2020 Jul; ():. PubMed ID: 32743566
[TBL] [Abstract][Full Text] [Related]
15. Combining magnetic resonance imaging with readout and/or perturbation of neural activity in animal models: Advantages and pitfalls.
Kosten L; Emmi SA; Missault S; Keliris GA
Front Neurosci; 2022; 16():938665. PubMed ID: 35911983
[TBL] [Abstract][Full Text] [Related]
16. Toward Completely Sampled Extracellular Neural Recording During fMRI.
Cruttenden CE; Zhu W; Zhang Y; Zhu XH; Chen W; Rajamani R
IEEE Trans Med Imaging; 2022 Jul; 41(7):1735-1746. PubMed ID: 35120000
[TBL] [Abstract][Full Text] [Related]
17. Multi-band SWIFT enables quiet and artefact-free EEG-fMRI and awake fMRI studies in rat.
Paasonen J; Laakso H; Pirttimäki T; Stenroos P; Salo RA; Zhurakovskaya E; Lehto LJ; Tanila H; Garwood M; Michaeli S; Idiyatullin D; Mangia S; Gröhn O
Neuroimage; 2020 Feb; 206():116338. PubMed ID: 31730923
[TBL] [Abstract][Full Text] [Related]
18. Carbon monofilament electrodes for unit recording and functional MRI in same subjects.
Chuapoco MR; Choy M; Schmid F; Duffy BA; Lee HJ; Lee JH
Neuroimage; 2019 Feb; 186():806-816. PubMed ID: 30391560
[TBL] [Abstract][Full Text] [Related]
19. Resting state functional network disruptions in a kainic acid model of temporal lobe epilepsy.
Gill RS; Mirsattari SM; Leung LS
Neuroimage Clin; 2017; 13():70-81. PubMed ID: 27942449
[TBL] [Abstract][Full Text] [Related]
20. MRI compatible optrodes for simultaneous LFP and optogenetic fMRI investigation of seizure-like afterdischarges.
Duffy BA; Choy M; Chuapoco MR; Madsen M; Lee JH
Neuroimage; 2015 Dec; 123():173-84. PubMed ID: 26208873
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]