These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
149 related articles for article (PubMed ID: 15679144)
21. Characterization of reversed-phase columns using the linear free energy relationship. III. Effect of the organic modifier and the mobile phase composition. Sándi A; Nagy M; Szepesy L J Chromatogr A; 2000 Oct; 893(2):215-34. PubMed ID: 11073293 [TBL] [Abstract][Full Text] [Related]
22. Polycyclic aromatic hydrocarbons as test probes to investigate the retention behavior of 1,3-alternate calix[4]arene silica-bonded stationary phases. Sliwka-Kaszyńska M; Slebioda M J Sep Sci; 2014 Mar; 37(5):543-50. PubMed ID: 24347443 [TBL] [Abstract][Full Text] [Related]
23. Contributions to reversed-phase column selectivity. II. Cation exchange. Marchand DH; Carr PW; McCalley DV; Neue UD; Dolan JW; Snyder LR J Chromatogr A; 2011 Oct; 1218(40):7110-29. PubMed ID: 21872865 [TBL] [Abstract][Full Text] [Related]
24. Column selectivity in reversed-phase liquid chromatography II. Effect of a change in conditions. Wilson NS; Nelson MD; Dolan JW; Snyder LR; Carr PW J Chromatogr A; 2002 Jul; 961(2):195-215. PubMed ID: 12184619 [TBL] [Abstract][Full Text] [Related]
25. Size exclusion chromatography of synthetic polymers and biopolymers on common reversed phase and hydrophilic interaction chromatography columns. Caltabiano AM; Foley JP; Barth HG J Chromatogr A; 2016 Mar; 1437():74-87. PubMed ID: 26877177 [TBL] [Abstract][Full Text] [Related]
26. Investigating retention characteristics of a mixed-mode stationary phase and the enhancement of monolith selectivity for high-performance liquid chromatography. Bassanese DN; Soliven A; Stevenson PG; Dennis GR; Barnett NW; Shalliker RA; Conlan XA J Sep Sci; 2014 Aug; 37(15):1937-43. PubMed ID: 24824418 [TBL] [Abstract][Full Text] [Related]
27. Retention and selectivity effects caused by bonding of a polar urea-type ligand to silica: a study on mixed-mode retention mechanisms and the pivotal role of solute-silanol interactions in the hydrophilic interaction chromatography elution mode. Bicker W; Wu J; Yeman H; Albert K; Lindner W J Chromatogr A; 2011 Feb; 1218(7):882-95. PubMed ID: 21067765 [TBL] [Abstract][Full Text] [Related]
29. Impact of pore structural parameters on column performance and resolution of reversed-phase monolithic silica columns for peptides and proteins. Skudas R; Grimes BA; Machtejevas E; Kudirkaite V; Kornysova O; Hennessy TP; Lubda D; Unger KK J Chromatogr A; 2007 Mar; 1144(1):72-84. PubMed ID: 17084406 [TBL] [Abstract][Full Text] [Related]
30. Description and comparison of chromatographic tests and chemometric methods for packed column classification. Lesellier E; West C J Chromatogr A; 2007 Jul; 1158(1-2):329-60. PubMed ID: 17467721 [TBL] [Abstract][Full Text] [Related]
31. Selectivity of calixarene-bonded silica-phases in HPLC: description of special characteristics with a multiple term linear equation at two different pH-values. Schneider C; Meyer R; Jira T Anal Sci; 2008 Sep; 24(9):1157-64. PubMed ID: 18781029 [TBL] [Abstract][Full Text] [Related]
32. Repeatability and reproducibility of retention data and band profiles on reversed-phase liquid chromatography columns. III. Results obtained with Kromasil C18 columns. Kele M; Guiochon G J Chromatogr A; 1999 Sep; 855(2):423-53. PubMed ID: 10519085 [TBL] [Abstract][Full Text] [Related]
33. Study of the selectivity of reversed-phase columns for the separation of polycarboxylic acids and polyphenol compounds. Whelan TJ; Gray MJ; Slonecker PJ; Shalliker RA; Wilson MA J Chromatogr A; 2005 Dec; 1097(1-2):148-56. PubMed ID: 16298194 [TBL] [Abstract][Full Text] [Related]
34. Hydrophilic-subtraction model for the characterization and comparison of hydrophilic interaction liquid chromatography columns. Wang J; Guo Z; Shen A; Yu L; Xiao Y; Xue X; Zhang X; Liang X J Chromatogr A; 2015 Jun; 1398():29-46. PubMed ID: 25935798 [TBL] [Abstract][Full Text] [Related]
35. Effect of long-term storage and use on the properties of reversed-phase liquid chromatographic columns. Haghedooren E; Farkas E; Kerner A; Dragovic S; Noszál B; Hoogmartens J; Adams E Talanta; 2008 Jun; 76(1):172-82. PubMed ID: 18585260 [TBL] [Abstract][Full Text] [Related]
36. Intergroup cross-comparison for the evaluation of data-interchangeability from various chromatographic tests. Chamseddin C; Molnár I; Jira T J Chromatogr A; 2013 Jul; 1297():146-56. PubMed ID: 23726085 [TBL] [Abstract][Full Text] [Related]
37. Chromatographic test methods for characterizing alkylsiloxane-bonded silica columns for reversed-phase liquid chromatography. Poole CF J Chromatogr B Analyt Technol Biomed Life Sci; 2018 Aug; 1092():207-219. PubMed ID: 29908470 [TBL] [Abstract][Full Text] [Related]
38. Preparation and evaluation of a novel bonded imidazolium ionic liquid as stationary phase for gas chromatography. Dai JL; Zhao LH; Shi JH J Sep Sci; 2017 Jul; 40(13):2769-2778. PubMed ID: 28481044 [TBL] [Abstract][Full Text] [Related]