These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

70 related articles for article (PubMed ID: 1567915)

  • 1. Determination of SQ 33,600, a phosphinic acid containing HMG CoA reductase inhibitor, in human serum by high-performance liquid chromatography combined with ionspray mass spectrometry.
    Wang-Iverson D; Arnold ME; Jemal M; Cohen AI
    Biol Mass Spectrom; 1992 Apr; 21(4):189-94. PubMed ID: 1567915
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An automated method for the simultaneous determination of pravastatin and its main metabolite in human plasma by high-performance liquid chromatography/atmospheric pressure chemical ionization mass spectrometry.
    Kawabata K; Matsushima N; Sasahara K
    Biomed Chromatogr; 1998; 12(5):271-5. PubMed ID: 9787898
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Determination of two HMG-CoA reductase inhibitors, pravastatin and pitavastatin, in plasma samples using liquid chromatography-tandem mass spectrometry for pharmaceutical study.
    Deng JW; Kim KB; Song IS; Shon JH; Zhou HH; Liu KH; Shin JG
    Biomed Chromatogr; 2008 Feb; 22(2):131-5. PubMed ID: 17703482
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Liquid chromatography/negative ion electrospray tandem mass spectrometry method for the quantification of fluvastatin in human plasma: validation and its application to pharmacokinetic studies.
    Nirogi RV; Kandikere VN; Shrivastava W; Mudigonda K; Datla PV
    Rapid Commun Mass Spectrom; 2006; 20(8):1225-30. PubMed ID: 16541405
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantitation of the acid and lactone forms of atorvastatin and its biotransformation products in human serum by high-performance liquid chromatography with electrospray tandem mass spectrometry.
    Jemal M; Ouyang Z; Chen BC; Teitz D
    Rapid Commun Mass Spectrom; 1999; 13(11):1003-15. PubMed ID: 10368976
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The use of high-flow high performance liquid chromatography coupled with positive and negative ion electrospray tandem mass spectrometry for quantitative bioanalysis via direct injection of the plasma/serum samples.
    Jemal M; Xia YQ; Whigan DB
    Rapid Commun Mass Spectrom; 1998; 12(19):1389-99. PubMed ID: 9773524
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of a prostaglandin D2 antagonist and its acyl glucuronide metabolite in human plasma by high performance liquid chromatography with tandem mass spectrometric detection--a lack of MS/MS selectivity between a glucuronide conjugate and a phase I metabolite.
    Schwartz MS; Desai RB; Bi S; Miller AR; Matuszewski BK
    J Chromatogr B Analyt Technol Biomed Life Sci; 2006 Jun; 837(1-2):116-24. PubMed ID: 16716772
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Atmospheric pressure ionization time-of-flight mass spectrometry coupled with fast liquid chromatography for quantitation and accurate mass measurement of five pharmaceutical drugs in human plasma.
    Zhang H; Heinig K; Henion J
    J Mass Spectrom; 2000 Mar; 35(3):423-31. PubMed ID: 10767773
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A rapid and sensitive liquid chromatography/negative ion tandem mass spectrometry method for the determination of an indolocarbazole in human plasma using 96-well diatomaceous earth plates for solid-liquid extraction [correction of using internal standard (IS) 96-well diatomaceous earth plates for solid-liquid extraction].
    Wang AQ; Zeng W; Musson DG; Rogers JD; Fisher AL
    Rapid Commun Mass Spectrom; 2002; 16(10):975-81. PubMed ID: 11968130
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Simultaneous determination of tenidap and its stable isotope analog in serum by high-performance liquid chromatography/atmospheric pressure chemical ionization tandem mass spectrometry.
    Avery MJ; Mitchell DY; Falkner FC; Fouda HG
    Biol Mass Spectrom; 1992 Jul; 21(7):353-7. PubMed ID: 1420376
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Chiral evaluation of fluvastatin in human plasma by high-performance liquid chromatography electrospray mass spectrometry.
    Di Pietro G; Coelho EB; Geleilete TM; Marques MP; Lanchote VL
    J Chromatogr B Analyt Technol Biomed Life Sci; 2006 Mar; 832(2):256-61. PubMed ID: 16480934
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sensitivity enhancement in liquid chromatography/atmospheric pressure ionization mass spectrometry using derivatization and mobile phase additives.
    Gao S; Zhang ZP; Karnes HT
    J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Oct; 825(2):98-110. PubMed ID: 15897015
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Quantitative determination of rosuvastatin in human plasma by ion pair liquid-liquid extraction using liquid chromatography with electrospray ionization tandem mass spectrometry.
    Lan K; Jiang X; Li Y; Wang L; Zhou J; Jiang Q; Ye L
    J Pharm Biomed Anal; 2007 Jun; 44(2):540-6. PubMed ID: 17289330
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Liquid chromatography/tandem mass spectrometry methods for quantitation of mevalonic acid in human plasma and urine: method validation, demonstration of using a surrogate analyte, and demonstration of unacceptable matrix effect in spite of use of a stable isotope analog internal standard.
    Jemal M; Schuster A; Whigan DB
    Rapid Commun Mass Spectrom; 2003; 17(15):1723-34. PubMed ID: 12872277
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quantification of trandolapril and its metabolite trandolaprilat in human plasma by liquid chromatography/tandem mass spectrometry using solid-phase extraction.
    Nirogi RV; Kandikere VN; Shrivastava W; Mudigonda K
    Rapid Commun Mass Spectrom; 2006; 20(24):3709-16. PubMed ID: 17117442
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantitative determination of fluvastatin in human plasma by gas chromatography/negative ion chemical ionization mass spectrometry using [18O2]-fluvastatin as an internal standard.
    Leis HJ; Windischhofer W
    Rapid Commun Mass Spectrom; 2005; 19(2):128-32. PubMed ID: 15593066
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Analysis of five HMG-CoA reductase inhibitors-- atorvastatin, lovastatin, pravastatin, rosuvastatin and simvastatin: pharmacological, pharmacokinetic and analytical overview and development of a new method for use in pharmaceutical formulations analysis and in vitro metabolism studies.
    Pasha MK; Muzeeb S; Basha SJ; Shashikumar D; Mullangi R; Srinivas NR
    Biomed Chromatogr; 2006 Mar; 20(3):282-93. PubMed ID: 16143964
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determination of a novel gamma-secretase inhibitor in human plasma and cerebrospinal fluid using automated 96 well solid phase extraction and liquid chromatography/tandem mass spectrometry.
    Matthews CZ; Woolf EJ
    J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Feb; 863(1):36-45. PubMed ID: 18249589
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Determination of a novel substance P inhibitor in human plasma by high-performance liquid chromatography with atmospheric pressure chemical ionization mass spectrometric detection using single and triple quadrupole detectors.
    Constanzer ML; Chavez-Eng CM; Dru J; Kline WF; Matuszewski BK
    J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Aug; 807(2):243-50. PubMed ID: 15203036
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Simultaneous determination of a novel KDR kinase inhibitor and its N-oxide metabolite in human plasma using 96-well solid-phase extraction and liquid chromatography/tandem mass spectrometry.
    Xu Y; Du L; Soli ED; Braun MP; Dean DC; Musson DG
    J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Mar; 817(2):287-96. PubMed ID: 15686997
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.