These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

51 related articles for article (PubMed ID: 15681323)

  • 1. In vivo validation of a novel semi-automated method for border detection in intravascular ultrasound images.
    Bourantas CV; Plissiti ME; Fotiadis DI; Protopappas VC; Mpozios GV; Katsouras CS; Kourtis IC; Rees MR; Michalis LK
    Br J Radiol; 2005 Feb; 78(926):122-9. PubMed ID: 15681323
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A novel active contour model for fully automated segmentation of intravascular ultrasound images: in vivo validation in human coronary arteries.
    Giannoglou GD; Chatzizisis YS; Koutkias V; Kompatsiaris I; Papadogiorgaki M; Mezaris V; Parissi E; Diamantopoulos P; Strintzis MG; Maglaveras N; Parcharidis GE; Louridas GE
    Comput Biol Med; 2007 Sep; 37(9):1292-302. PubMed ID: 17291482
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Image analysis techniques for automated IVUS contour detection.
    Papadogiorgaki M; Mezaris V; Chatzizisis YS; Giannoglou GD; Kompatsiaris I
    Ultrasound Med Biol; 2008 Sep; 34(9):1482-98. PubMed ID: 18439746
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An artificial neural network method for lumen and media-adventitia border detection in IVUS.
    Su S; Hu Z; Lin Q; Hau WK; Gao Z; Zhang H
    Comput Med Imaging Graph; 2017 Apr; 57():29-39. PubMed ID: 28062170
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Improved automated lumen contour detection by novel multifrequency processing algorithm with current intravascular ultrasound system.
    Kume T; Kim BK; Waseda K; Sathyanarayana S; Li W; Teo TJ; Yock PG; Fitzgerald PJ; Honda Y
    Catheter Cardiovasc Interv; 2013 Feb; 81(3):E173-7. PubMed ID: 21805600
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Tissue characterization in intravascular ultrasound images.
    Zhang X; McKay CR; Sonka M
    IEEE Trans Med Imaging; 1998 Dec; 17(6):889-99. PubMed ID: 10048846
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Variability of a three-layered appearance in intravascular ultrasound coronary images: a comparison of morphometric measurements with four intravascular ultrasound systems.
    Hiro T; Leung CY; Russo RJ; Karimi H; Farvid AR; Tobis JM
    Am J Card Imaging; 1996 Oct; 10(4):219-27. PubMed ID: 9012388
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ultrasound-assisted stent implantation in small size coronary arteries: a pilot study.
    Ortolani P; Marzocchi A; Marrozzini C; Palmerini T; Saia F; Aquilina M; Corlianò L; Camplese G; Sbarzaglia P; Branzi A
    Ital Heart J; 2001 May; 2(5):372-8. PubMed ID: 11392642
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Angiographically silent left main disease detected by intravascular ultrasound: a marker for future adverse cardiac events.
    Ricciardi MJ; Meyers S; Choi K; Pang JL; Goodreau L; Davidson CJ
    Am Heart J; 2003 Sep; 146(3):507-12. PubMed ID: 12947371
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Duration of development of symptomatic in-stent restenosis correlates with the stent-to-vessel-diameter ratio: an intravascular ultrasound study.
    Schukro C; Gruska M; Syeda B; Winkler M; Poradek T; Sipötz H; Glogar D; Gaul G
    Coron Artery Dis; 2007 Nov; 18(7):507-12. PubMed ID: 17925602
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [New methods of coronary imaging II. Intracoronary ultrasonography in clinical practice].
    Sgura FA; Di Mario C
    Ital Heart J Suppl; 2001 Jun; 2(6):579-92. PubMed ID: 11460831
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Assessment of Inter-Expert Variability and of an Automated Segmentation Method of 40 and 60 MHz IVUS Images of Coronary Arteries.
    Destrempes F; Roy Cardinal MH; Saijo Y; Finet G; Tardif JC; Cloutier G
    PLoS One; 2017; 12(1):e0168332. PubMed ID: 28107355
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intravascular ultrasound and stent implantation: intraobserver and interobserver variability.
    Blessing E; Hausmann D; Sturm M; Wolpers HG; Amende I; Mügge A
    Am Heart J; 1999 Feb; 137(2):368-71. PubMed ID: 9924173
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Advanced deep learning methodology for accurate, real-time segmentation of high-resolution intravascular ultrasound images.
    Bajaj R; Huang X; Kilic Y; Ramasamy A; Jain A; Ozkor M; Tufaro V; Safi H; Erdogan E; Serruys PW; Moon J; Pugliese F; Mathur A; Torii R; Baumbach A; Dijkstra J; Zhang Q; Bourantas CV
    Int J Cardiol; 2021 Sep; 339():185-191. PubMed ID: 34153412
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Stent design related neointimal tissue proliferation in human coronary arteries; an intravascular ultrasound study.
    Hoffmann R; Jansen C; König A; Haager PK; Kerckhoff G; vom Dahl J; Klauss V; Hanrath P; Mudra H
    Eur Heart J; 2001 Nov; 22(21):2007-14. PubMed ID: 11603908
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Small stent size and intimal hyperplasia contribute to restenosis: a volumetric intravascular ultrasound analysis.
    Dussaillant GR; Mintz GS; Pichard AD; Kent KM; Satler LF; Popma JJ; Wong SC; Leon MB
    J Am Coll Cardiol; 1995 Sep; 26(3):720-4. PubMed ID: 7642865
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Low variation and high reproducibility in plaque volume with intravascular ultrasound.
    Jensen LO; Thayssen P; Pedersen KE; Stender S; Haghfelt T
    Int J Cardiol; 2004 Dec; 97(3):463-9. PubMed ID: 15561334
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Value of intravascular ultrasound in the assessment of coronary pseudostenosis during coronary interventions.
    Alfonso F; Delgado A; Magalhaes D; Goicolea J; Hernández R; Fernández-Ortíz A; Escaned J; Banũelos C; Cortés J; Flores A; Macaya C
    Catheter Cardiovasc Interv; 1999 Mar; 46(3):327-32. PubMed ID: 10348131
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of coronary minimal lumen area quantification by sixty-four-slice computed tomography versus intravascular ultrasound for intermediate stenosis.
    Caussin C; Larchez C; Ghostine S; Pesenti-Rossi D; Daoud B; Habis M; Sigal-Cinqualbre A; Perrier E; Angel CY; Lancelin B; Paul JF
    Am J Cardiol; 2006 Oct; 98(7):871-6. PubMed ID: 16996865
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Automated contour detection for high-frequency intravascular ultrasound imaging: a technique with blood noise reduction for edge enhancement.
    Takagi A; Hibi K; Zhang X; Teo TJ; Bonneau HN; Yock PG; Fitzgerald PJ
    Ultrasound Med Biol; 2000 Jul; 26(6):1033-41. PubMed ID: 10996703
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 3.