380 related articles for article (PubMed ID: 15683148)
1. A novel adaptive wrist actigraphy algorithm for sleep-wake assessment in sleep apnea patients.
Hedner J; Pillar G; Pittman SD; Zou D; Grote L; White DP
Sleep; 2004 Dec; 27(8):1560-6. PubMed ID: 15683148
[TBL] [Abstract][Full Text] [Related]
2. Validation of actigraphy for determining sleep and wake in children with sleep disordered breathing.
Hyde M; O'Driscoll DM; Binette S; Galang C; Tan SK; Verginis N; Davey MJ; Horne RS
J Sleep Res; 2007 Jun; 16(2):213-6. PubMed ID: 17542951
[TBL] [Abstract][Full Text] [Related]
3. Detecting REM sleep from the finger: an automatic REM sleep algorithm based on peripheral arterial tone (PAT) and actigraphy.
Herscovici S; Pe'er A; Papyan S; Lavie P
Physiol Meas; 2007 Feb; 28(2):129-40. PubMed ID: 17237585
[TBL] [Abstract][Full Text] [Related]
4. Sleep staging based on autonomic signals: a multi-center validation study.
Hedner J; White DP; Malhotra A; Herscovici S; Pittman SD; Zou D; Grote L; Pillar G
J Clin Sleep Med; 2011 Jun; 7(3):301-6. PubMed ID: 21677901
[TBL] [Abstract][Full Text] [Related]
5. Comparison of a novel non-contact biomotion sensor with wrist actigraphy in estimating sleep quality in patients with obstructive sleep apnoea.
Pallin M; O'Hare E; Zaffaroni A; Boyle P; Fagan C; Kent B; Heneghan C; de Chazal P; McNicholas WT
J Sleep Res; 2014 Aug; 23(4):475-84. PubMed ID: 24495222
[TBL] [Abstract][Full Text] [Related]
6. Wrist actigraphic scoring for sleep laboratory patients: algorithm development.
Kripke DF; Hahn EK; Grizas AP; Wadiak KH; Loving RT; Poceta JS; Shadan FF; Cronin JW; Kline LE
J Sleep Res; 2010 Dec; 19(4):612-9. PubMed ID: 20408923
[TBL] [Abstract][Full Text] [Related]
7. Automatic sleep/wake identification from wrist activity.
Cole RJ; Kripke DF; Gruen W; Mullaney DJ; Gillin JC
Sleep; 1992 Oct; 15(5):461-9. PubMed ID: 1455130
[TBL] [Abstract][Full Text] [Related]
8. How accurately does wrist actigraphy identify the states of sleep and wakefulness?
Pollak CP; Tryon WW; Nagaraja H; Dzwonczyk R
Sleep; 2001 Dec; 24(8):957-65. PubMed ID: 11766166
[TBL] [Abstract][Full Text] [Related]
9. Comparison between informant-observed and actigraphic assessments of sleep-wake rhythm disturbances in demented residents of homes for the elderly.
Hoekert M; der Lek RF; Swaab DF; Kaufer D; Van Someren EJ
Am J Geriatr Psychiatry; 2006 Feb; 14(2):104-11. PubMed ID: 16473974
[TBL] [Abstract][Full Text] [Related]
10. Detecting sleep using heart rate and motion data from multisensor consumer-grade wearables, relative to wrist actigraphy and polysomnography.
Roberts DM; Schade MM; Mathew GM; Gartenberg D; Buxton OM
Sleep; 2020 Jul; 43(7):. PubMed ID: 32215550
[TBL] [Abstract][Full Text] [Related]
11. Validation a portable monitoring device for sleep apnea diagnosis in a population based cohort using synchronized home polysomnography.
Zou D; Grote L; Peker Y; Lindblad U; Hedner J
Sleep; 2006 Mar; 29(3):367-74. PubMed ID: 16553023
[TBL] [Abstract][Full Text] [Related]
12. Algorithms for using an activity-based accelerometer for identification of infant sleep-wake states during nap studies.
Galland BC; Kennedy GJ; Mitchell EA; Taylor BJ
Sleep Med; 2012 Jun; 13(6):743-51. PubMed ID: 22542788
[TBL] [Abstract][Full Text] [Related]
13. Validation of Actigraphy in Middle Childhood.
Meltzer LJ; Wong P; Biggs SN; Traylor J; Kim JY; Bhattacharjee R; Narang I; Marcus CL;
Sleep; 2016 Jun; 39(6):1219-24. PubMed ID: 27091520
[TBL] [Abstract][Full Text] [Related]
14. Comparison of three actigraphic algorithms used to evaluate sleep in patients with obstructive sleep apnea.
Kim MJ; Lee GH; Kim CS; Kim WS; Chung YS; Chung S; Lee SA
Sleep Breath; 2013 Mar; 17(1):297-304. PubMed ID: 22447172
[TBL] [Abstract][Full Text] [Related]
15. Wake detection capacity of actigraphy during sleep.
Paquet J; Kawinska A; Carrier J
Sleep; 2007 Oct; 30(10):1362-9. PubMed ID: 17969470
[TBL] [Abstract][Full Text] [Related]
16. Improving Sleep Quality Assessment Using Wearable Sensors by Including Information From Postural/Sleep Position Changes and Body Acceleration: A Comparison of Chest-Worn Sensors, Wrist Actigraphy, and Polysomnography.
Razjouyan J; Lee H; Parthasarathy S; Mohler J; Sharafkhaneh A; Najafi B
J Clin Sleep Med; 2017 Nov; 13(11):1301-1310. PubMed ID: 28992827
[TBL] [Abstract][Full Text] [Related]
17. Energy expenditure in obstructive sleep apnea: validation of a multiple physiological sensor for determination of sleep and wake.
O'Driscoll DM; Turton AR; Copland JM; Strauss BJ; Hamilton GS
Sleep Breath; 2013 Mar; 17(1):139-46. PubMed ID: 22318784
[TBL] [Abstract][Full Text] [Related]
18. Sleep/wake measurement using a non-contact biomotion sensor.
De Chazal P; Fox N; O'Hare E; Heneghan C; Zaffaroni A; Boyle P; Smith S; O'Connell C; McNicholas WT
J Sleep Res; 2011 Jun; 20(2):356-66. PubMed ID: 20704645
[TBL] [Abstract][Full Text] [Related]
19. AASM standards of practice compliant validation of actigraphic sleep analysis from SOMNOwatchâ„¢ versus polysomnographic sleep diagnostics shows high conformity also among subjects with sleep disordered breathing.
Dick R; Penzel T; Fietze I; Partinen M; Hein H; Schulz J
Physiol Meas; 2010 Dec; 31(12):1623-33. PubMed ID: 21071830
[TBL] [Abstract][Full Text] [Related]
20. Activity-based sleep-wake identification: an empirical test of methodological issues.
Sadeh A; Sharkey KM; Carskadon MA
Sleep; 1994 Apr; 17(3):201-7. PubMed ID: 7939118
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]