  • 21. Wear of '100 Mrad' cross-linked polyethylene: effects of packaging after 30 years real-time shelf-aging.
    Kyomoto M; Ueno M; Kim SC; Oonishi H; Oonishi H
    J Biomater Sci Polym Ed; 2007; 18(1):59-70. PubMed ID: 17274451
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparison of the size and morphology of UHMWPE wear debris produced by a hip joint simulator under serum and water lubricated conditions.
    Wang A; Essner A; Stark C; Dumbleton JH
    Biomaterials; 1996 May; 17(9):865-71. PubMed ID: 8718931
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Strain-induced microstructural rearrangement in ultra-high molecular weight polyethylene for hip joints: A comparison between conventional and vitamin E-infused highly-crosslinked liners.
    Takahashi Y; Yamamoto K; Shishido T; Masaoka T; Tateiwa T; Puppulin L; Pezzotti G
    J Mech Behav Biomed Mater; 2014 Mar; 31():31-44. PubMed ID: 23394750
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A simple fully integrated contact-coupled wear prediction for ultra-high molecular weight polyethylene hip implants.
    Kang L; Galvin AL; Jin ZM; Fisher J
    Proc Inst Mech Eng H; 2006 Jan; 220(1):33-46. PubMed ID: 16459444
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulators.
    Tipper JL; Galvin AL; Williams S; McEwen HM; Stone MH; Ingham E; Fisher J
    J Biomed Mater Res A; 2006 Sep; 78(3):473-80. PubMed ID: 16721797
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Can Sequentially-irradiated and Annealed Highly Cross-linked Polyethylene Inserts Thinner than Eight-millimeters Be Utilized in Total Knee Arthroplasty?
    Sayeed SA; Jauregui JJ; Korduba LA; Essner A; Harwin SF; Delanois RE; Mont MA
    Surg Technol Int; 2015 May; 26():329-35. PubMed ID: 26055028
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Gradient crosslinking of UHMWPE using irradiation in molten state for total joint arthroplasty.
    Muratoglu OK; O'Connor DO; Bragdon CR; Delaney J; Jasty M; Harris WH; Merrill E; Venugopalan P
    Biomaterials; 2002 Feb; 23(3):717-24. PubMed ID: 11771692
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Wear simulation of total hip prostheses with polyethylene against CoCr, alumina and diamond-like carbon.
    Saikko V; Ahlroos T; Calonius O; Keränen J
    Biomaterials; 2001 Jun; 22(12):1507-14. PubMed ID: 11374449
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Evaluation of cytotoxicity of UHMWPE wear debris.
    Rao S; Shirata K; Furukawa KS; Ushida T; Tateishi T; Kanazawa M; Katsube S; Janna S
    Biomed Mater Eng; 1999; 9(4):209-17. PubMed ID: 10674175
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Third-body wear of highly cross-linked polyethylene in a hip simulator.
    Bragdon CR; Jasty M; Muratoglu OK; O'Connor DO; Harris WH
    J Arthroplasty; 2003 Aug; 18(5):553-61. PubMed ID: 12934205
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparison of the in vivo wear rates of 43 surgically retrieved direct compression molded and ram extruded ultra high molecular weight polyethylene acetabular components.
    Rentfrow ED; James SP; Beauregard GP; Lee KR; McLaughlin JR
    Biomed Sci Instrum; 1996; 32():135-41. PubMed ID: 8672661
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Do tissues from THA revision of highly crosslinked UHMWPE liners contain wear debris and associated inflammation?
    Baxter RM; Freeman TA; Kurtz SM; Steinbeck MJ
    Clin Orthop Relat Res; 2011 Aug; 469(8):2308-17. PubMed ID: 21136220
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Time- and depth-dependent changes in crosslinking and oxidation of shelf-aged polyethylene acetabular liners.
    Jacob RJ; Pienkowski D; Lee KY; Hamilton DM; Schroeder D; Higgins J
    J Biomed Mater Res; 2001 Aug; 56(2):168-76. PubMed ID: 11340586
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Comparison of wear of ultra-high molecular weight polyethylene acetabular cups against surface-engineered femoral heads.
    Galvin A; Brockett C; Williams S; Hatto P; Burton A; Isaac G; Stone M; Ingham E; Fisher J
    Proc Inst Mech Eng H; 2008 Oct; 222(7):1073-80. PubMed ID: 19024155
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The influence of molecular weight, crosslinking and counterface roughness on TNF-alpha production by macrophages in response to ultra high molecular weight polyethylene particles.
    Ingram JH; Stone M; Fisher J; Ingham E
    Biomaterials; 2004 Aug; 25(17):3511-22. PubMed ID: 15020125
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Microwear phenomena of ultrahigh molecular weight polyethylene cups and debris morphology related to gamma radiation dose in simulator study.
    Yamamoto K; Clarke IC; Masaoka T; Oonishi H; Williams PA; Good VD; Imakiire A
    J Biomed Mater Res; 2001 Jul; 56(1):65-73. PubMed ID: 11309792
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Influence of design and bearing material on polyethylene wear particle generation in total knee replacement.
    Utzschneider S; Paulus A; Datz JC; Schroeder C; Sievers B; Wegener B; Jansson V
    Acta Biomater; 2009 Sep; 5(7):2495-502. PubMed ID: 19375997
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Surface micromechanics of ultrahigh molecular weight polyethylene: Microindentation testing, crosslinking, and material behavior.
    Gilbert JL; Cumber J; Butterfield A
    J Biomed Mater Res; 2002 Aug; 61(2):270-81. PubMed ID: 12007208
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Wear of conventional and cross-linked ultra-high-molecular-weight polyethylene acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulator.
    Saikko V; Calonius O; Keränen J
    J Biomed Mater Res; 2002; 63(6):848-53. PubMed ID: 12418033
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Do temperature variations at the bearing surface during gait affect polyethylene wear in Charnley low-friction arthroplasty of the hip? Simulator study comparing UHMWPE and highly cross-linked polyethylene.
    Roussignol X; Siedlecki C; Duparc F; Dujardin F; Ould-Slimane M
    Orthop Traumatol Surg Res; 2016 Oct; 102(6):711-5. PubMed ID: 27318806
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]