BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

223 related articles for article (PubMed ID: 15686095)

  • 1. Resistance of ITI implant connectors to multivectorial fatigue load application.
    Wiskott HW; Pavone AF; Scherrer SS; Renevey RR; Belser UC
    Int J Prosthodont; 2004; 17(6):672-9. PubMed ID: 15686095
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Resistance of internal-connection implant connectors under rotational fatigue loading.
    Wiskott HW; Jaquet R; Scherrer SS; Belser UC
    Int J Oral Maxillofac Implants; 2007; 22(2):249-57. PubMed ID: 17465350
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dynamic fatigue properties of the dental implant-abutment interface: joint opening in wide-diameter versus standard-diameter hex-type implants.
    Hoyer SA; Stanford CM; Buranadham S; Fridrich T; Wagner J; Gratton D
    J Prosthet Dent; 2001 Jun; 85(6):599-607. PubMed ID: 11404760
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Load fatigue performance of implant-ceramic abutment combinations.
    Nguyen HQ; Tan KB; Nicholls JI
    Int J Oral Maxillofac Implants; 2009; 24(4):636-46. PubMed ID: 19885403
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Fatigue resistance of two implant/abutment joint designs.
    Khraisat A; Stegaroiu R; Nomura S; Miyakawa O
    J Prosthet Dent; 2002 Dec; 88(6):604-10. PubMed ID: 12488853
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of implant connection and restoration design (screwed vs. cemented) in reliability and failure modes of anterior crowns.
    Freitas AC; Bonfante EA; Rocha EP; Silva NR; Marotta L; Coelho PG
    Eur J Oral Sci; 2011 Aug; 119(4):323-30. PubMed ID: 21726295
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of engaging abutment position in implant-borne, screw-retained three-unit fixed cantilevered prostheses.
    Dogus SM; Kurtz KS; Watanabe I; Griggs JA
    J Prosthodont; 2011 Jul; 20(5):348-54. PubMed ID: 21585587
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Critical bending moment of implant-abutment screw joint interfaces: effect of torque levels and implant diameter.
    Tan BF; Tan KB; Nicholls JI
    Int J Oral Maxillofac Implants; 2004; 19(5):648-58. PubMed ID: 15508980
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Load fatigue performance of four implant-abutment interface designs: effect of torque level and implant system.
    Quek HC; Tan KB; Nicholls JI
    Int J Oral Maxillofac Implants; 2008; 23(2):253-62. PubMed ID: 18548921
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vitro study of the influence of the type of connection on the fracture load of zirconia abutments with internal and external implant-abutment connections.
    Sailer I; Sailer T; Stawarczyk B; Jung RE; Hämmerle CH
    Int J Oral Maxillofac Implants; 2009; 24(5):850-8. PubMed ID: 19865625
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Implant abutment screw rotations and preloads for four different screw materials and surfaces.
    Martin WC; Woody RD; Miller BH; Miller AW
    J Prosthet Dent; 2001 Jul; 86(1):24-32. PubMed ID: 11458261
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effect of eliminating implant/abutment rotational misfit on screw joint stability.
    Binon PP; McHugh MJ
    Int J Prosthodont; 1996; 9(6):511-9. PubMed ID: 9171488
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The dynamic natures of implant loading.
    Wang RF; Kang B; Lang LA; Razzoog ME
    J Prosthet Dent; 2009 Jun; 101(6):359-71. PubMed ID: 19463663
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Implant-abutment screw joint preload of 7 hex-top abutment systems.
    Tan KB; Nicholls JI
    Int J Oral Maxillofac Implants; 2001; 16(3):367-77. PubMed ID: 11432656
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dynamic fatigue resistance of implant-abutment junction in an internally notched morse-taper oral implant: influence of abutment design.
    Cehreli MC; Akça K; Iplikçioğlu H; Sahin S
    Clin Oral Implants Res; 2004 Aug; 15(4):459-65. PubMed ID: 15248881
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Examination of the implant-abutment interface after fatigue testing.
    Cibirka RM; Nelson SK; Lang BR; Rueggeberg FA
    J Prosthet Dent; 2001 Mar; 85(3):268-75. PubMed ID: 11264934
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Load fatigue performance of two implant-abutment combinations.
    Basten CH; Nicholls JI; Daly CH; Taggart R
    Int J Oral Maxillofac Implants; 1996; 11(4):522-8. PubMed ID: 8803348
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fracture resistance and failure location of zirconium and metallic implant abutments.
    Aramouni P; Zebouni E; Tashkandi E; Dib S; Salameh Z; Almas K
    J Contemp Dent Pract; 2008 Nov; 9(7):41-8. PubMed ID: 18997915
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Resistance of three implant-abutment interfaces to fatigue testing.
    Ribeiro CG; Maia ML; Scherrer SS; Cardoso AC; Wiskott HW
    J Appl Oral Sci; 2011 Aug; 19(4):413-20. PubMed ID: 21710094
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Preloads generated with repeated tightening in three types of screws used in dental implant assemblies.
    Byrne D; Jacobs S; O'Connell B; Houston F; Claffey N
    J Prosthodont; 2006; 15(3):164-71. PubMed ID: 16681498
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.