378 related articles for article (PubMed ID: 15690150)
1. Suctioning through a double-lumen endotracheal tube helps to prevent alveolar collapse and to preserve ventilation.
Reissmann H; Böhm SH; Suárez-Sipmann F; Tusman G; Buschmann C; Maisch S; Pesch T; Thamm O; Plümers C; Schulte am Esch J; Hedenstierna G
Intensive Care Med; 2005 Mar; 31(3):431-40. PubMed ID: 15690150
[TBL] [Abstract][Full Text] [Related]
2. Can ventilator settings reduce the negative effects of endotracheal suctioning? Investigations in a mechanical lung model.
Nakstad ER; Opdahl H; Heyerdahl F; Borchsenius F; Skjønsberg OH
BMC Anesthesiol; 2016 Jun; 16(1):30. PubMed ID: 27350249
[TBL] [Abstract][Full Text] [Related]
3. Physiological responses to endotracheal and oral suctioning in paediatric patients: the influence of endotracheal tube sizes and suction pressures.
Singh NC; Kissoon N; Frewen T; Tiffin N
Clin Intensive Care; 1991; 2(6):345-50. PubMed ID: 10149098
[TBL] [Abstract][Full Text] [Related]
4. Manual ventilation and open suction procedures contribute to negative pressures in a mechanical lung model.
Nakstad ER; Opdahl H; Heyerdahl F; Borchsenius F; Skjønsberg OH
BMJ Open Respir Res; 2017; 4(1):e000176. PubMed ID: 28725445
[TBL] [Abstract][Full Text] [Related]
5. The effects of closed endotracheal suction on ventilation during conventional and high-frequency oscillatory ventilation.
Kiraly NJ; Tingay DG; Mills JF; Morley CJ; Dargaville PA; Copnell B
Pediatr Res; 2009 Oct; 66(4):400-4. PubMed ID: 19581839
[TBL] [Abstract][Full Text] [Related]
6. A 72-hour study to test the efficacy and safety of the "Mucus Slurper" in mechanically ventilated sheep.
Li Bassi G; Curto F; Zanella A; Stylianou M; Kolobow T
Crit Care Med; 2007 Mar; 35(3):906-11. PubMed ID: 17255853
[TBL] [Abstract][Full Text] [Related]
7. Effects of prolonged mechanical ventilation with a closed suction system on endotracheal tube resistance and its reversibility by a closed suction cleaning system.
Adi NA; Tomer NT; Bergman GB; Kishinevsky EK; Wyncoll DW
Anaesth Intensive Care; 2013 Nov; 41(6):728-35. PubMed ID: 24180713
[TBL] [Abstract][Full Text] [Related]
8. [Indications for the use of closed endotracheal suction. Artificial respiration with high positive end-expiratory pressure].
Weitl J; Bettstetter H
Anaesthesist; 1994 Jun; 43(6):359-63. PubMed ID: 8048770
[TBL] [Abstract][Full Text] [Related]
9. The impact of closed endotracheal suctioning systems on mechanical ventilator performance.
El Masry A; Williams PF; Chipman DW; Kratohvil JP; Kacmarek RM
Respir Care; 2005 Mar; 50(3):345-53. PubMed ID: 15737244
[TBL] [Abstract][Full Text] [Related]
10. Endotracheal Tube Seal and Suction Performance in a Novel Biorealistic Tracheal Model.
Rozycki SK; Dixon FP; Yopp MA; Maxvold NJ; Rubin BK
Respir Care; 2015 Aug; 60(8):1113-9. PubMed ID: 25944945
[TBL] [Abstract][Full Text] [Related]
11. Airway ventilation pressures during bronchoscopy, bronchial blocker, and double-lumen endotracheal tube use: an in vitro study.
Kuo AS; Philip JH; Edrich T
J Cardiothorac Vasc Anesth; 2014 Aug; 28(4):873-9. PubMed ID: 24021918
[TBL] [Abstract][Full Text] [Related]
12. Prevention of endotracheal suctioning-induced alveolar derecruitment in acute lung injury.
Maggiore SM; Lellouche F; Pigeot J; Taille S; Deye N; Durrmeyer X; Richard JC; Mancebo J; Lemaire F; Brochard L
Am J Respir Crit Care Med; 2003 May; 167(9):1215-24. PubMed ID: 12615633
[TBL] [Abstract][Full Text] [Related]
13. The Mucus Slurper: A novel tracheal tube that requires no tracheal tube suctioning. A preliminary report.
Kolobow T; Li Bassi G; Curto F; Zanella A
Intensive Care Med; 2006 Sep; 32(9):1414-8. PubMed ID: 16826389
[TBL] [Abstract][Full Text] [Related]
14. Bronchial blocker versus left double-lumen endotracheal tube in video-assisted thoracoscopic surgery: a randomized-controlled trial examining time and quality of lung deflation.
Bussières JS; Somma J; Del Castillo JL; Lemieux J; Conti M; Ugalde PA; Gagné N; Lacasse Y
Can J Anaesth; 2016 Jul; 63(7):818-27. PubMed ID: 27138896
[TBL] [Abstract][Full Text] [Related]
15. Endotracheal suctioning: from principles to practice.
Morrow BM; Futter MJ; Argent AC
Intensive Care Med; 2004 Jun; 30(6):1167-74. PubMed ID: 15034648
[TBL] [Abstract][Full Text] [Related]
16. Effect of applying positive pressure with or without endotracheal suctioning during extubation: a laboratory study.
Andreu MF; Salvati IG; Donnianni MC; Ibañez B; Cotignola M; Bezzi M
Respir Care; 2014 Dec; 59(12):1905-11. PubMed ID: 25425709
[TBL] [Abstract][Full Text] [Related]
17. Endotracheal tube resistance and inertance in a model of mechanical ventilation of newborns and small infants-the impact of ventilator settings on tracheal pressure swings.
Hentschel R; Buntzel J; Guttmann J; Schumann S
Physiol Meas; 2011 Sep; 32(9):1439-51. PubMed ID: 21799238
[TBL] [Abstract][Full Text] [Related]
18. Deep versus shallow suction of endotracheal tubes in ventilated neonates and young infants.
Spence K; Gillies D; Waterworth L
Cochrane Database Syst Rev; 2003; (3):CD003309. PubMed ID: 12917961
[TBL] [Abstract][Full Text] [Related]
19. Deep versus shallow suction of endotracheal tubes in ventilated neonates and young infants.
Gillies D; Spence K
Cochrane Database Syst Rev; 2011 Jul; 2011(7):CD003309. PubMed ID: 21735391
[TBL] [Abstract][Full Text] [Related]
20. An Artificial Cough Maneuver to Remove Secretions From Below the Endotracheal Tube Cuff.
Zanella A; Florio G; Rezoagli E; Pastore M; Cadringer P; Biancolilli O; Carlesso E; Scaravilli V; Ristagno G; Pesenti AM
Respir Care; 2019 Apr; 64(4):372-383. PubMed ID: 30622174
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]