These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 15690557)

  • 1. Detailed assessment of fetal ventricular septal defect with 4D color Doppler ultrasound using spatio-temporal image correlation technology.
    Yagel S; Valsky DV; Messing B
    Ultrasound Obstet Gynecol; 2005 Jan; 25(1):97-8. PubMed ID: 15690557
    [No Abstract]   [Full Text] [Related]  

  • 2. Inversion mode spatio-temporal image correlation (STIC) echocardiography in three-dimensional rendering of fetal ventricular septal defects.
    Ghi T; Cera E; Segata M; Michelacci L; Pilu G; Pelusi G
    Ultrasound Obstet Gynecol; 2005 Nov; 26(6):679-80. PubMed ID: 16254880
    [No Abstract]   [Full Text] [Related]  

  • 3. Examination of the fetal heart by four-dimensional (4D) ultrasound with spatio-temporal image correlation (STIC).
    Gonçalves LF; Lee W; Espinoza J; Romero R
    Ultrasound Obstet Gynecol; 2006 Mar; 27(3):336-48. PubMed ID: 16482611
    [No Abstract]   [Full Text] [Related]  

  • 4. Three-dimensional (3D) and 4D color Doppler fetal echocardiography using spatio-temporal image correlation (STIC).
    Chaoui R; Hoffmann J; Heling KS
    Ultrasound Obstet Gynecol; 2004 Jun; 23(6):535-45. PubMed ID: 15170792
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Novel application of 4D sonography with B-flow imaging and spatio-temporal image correlation (STIC) in the assessment of the anatomy of pulmonary arteries in fetuses with pulmonary atresia and ventricular septal defect.
    Volpe P; Campobasso G; Stanziano A; De Robertis V; Di Paolo S; Caruso G; Volpe N; Gentile M
    Ultrasound Obstet Gynecol; 2006 Jul; 28(1):40-6. PubMed ID: 16795133
    [TBL] [Abstract][Full Text] [Related]  

  • 6. First trimester two- and four-dimensional cardiac scan: intra- and interobserver agreement, comparison between methods and benefits of color Doppler technique.
    Tudorache S; Cara M; Iliescu DG; Novac L; Cernea N
    Ultrasound Obstet Gynecol; 2013 Dec; 42(6):659-68. PubMed ID: 23494803
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Contemporary clinical applications of spatio-temporal image correlation in prenatal diagnosis.
    Espinoza J
    Curr Opin Obstet Gynecol; 2011 Apr; 23(2):94-102. PubMed ID: 21178772
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Recent Development in Three and Four Dimension Fetal Echocardiography.
    Chaoui R; Abuhamad A; Martins J; Heling KS
    Fetal Diagn Ther; 2020; 47(5):345-353. PubMed ID: 31266014
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fetal cardiac stroke volume determination by four-dimensional ultrasound with spatio-temporal image correlation compared with two-dimensional and Doppler ultrasonography.
    Rizzo G; Capponi A; Cavicchioni O; Vendola M; Arduini D
    Prenat Diagn; 2007 Dec; 27(12):1147-50. PubMed ID: 17968855
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Feasibility and accuracy of fetal echocardiography using four-dimensional spatiotemporal image correlation technology before 16 weeks' gestation.
    Bennasar M; Martínez JM; Olivella A; del Río M; Gómez O; Figueras F; Puerto B; Gratacós E
    Ultrasound Obstet Gynecol; 2009 Jun; 33(6):645-51. PubMed ID: 19479815
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Four-dimensional ultrasonography of the fetal heart using a novel Tomographic Ultrasound Imaging display.
    Gonçalves LF; Espinoza J; Romero R; Kusanovic JP; Swope B; Nien JK; Erez O; Soto E; Treadwell MC
    J Perinat Med; 2006; 34(1):39-55. PubMed ID: 16489885
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Four-dimensional sonography of the fetal heart with spatiotemporal image correlation directed at the interventricular septum.
    Myers SA; Fresquez M; Hamill N
    J Ultrasound Med; 2007 Aug; 26(8):1071-5. PubMed ID: 17646369
    [TBL] [Abstract][Full Text] [Related]  

  • 13. 4D fetal echocardiography-An update.
    DeVore GR; Satou G; Sklansky M
    Echocardiography; 2017 Dec; 34(12):1788-1798. PubMed ID: 29287138
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Prenatal diagnosis of congenital left ventricular aneurysm by four-dimensional ultrasonography with spatio-temporal image correlation (STIC).
    Chiang YC; Yang CK; Shih JC; Lee CN
    Ultrasound Obstet Gynecol; 2006 Sep; 28(3):345-7. PubMed ID: 16909405
    [No Abstract]   [Full Text] [Related]  

  • 15. Four-dimensional color Doppler reconstruction of the fetal heart with glass-body rendering mode.
    Hata T; Kanenishi K; Mori N; Yazon AO; Hanaoka U; Tanaka H
    Am J Cardiol; 2014 Nov; 114(10):1603-6. PubMed ID: 25242366
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Heart stroke volume, cardiac output, and ejection fraction in 265 normal fetus in the second half of gestation assessed by 4D ultrasound using spatio-temporal image correlation.
    Simioni C; Nardozza LM; Araujo Júnior E; Rolo LC; Zamith M; Caetano AC; Moron AF
    J Matern Fetal Neonatal Med; 2011 Sep; 24(9):1159-67. PubMed ID: 21250911
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Standardization of on-screen fetal heart orientation prior to storage of spatio-temporal image correlation (STIC) volume datasets.
    Paladini D
    Ultrasound Obstet Gynecol; 2007 Jun; 29(6):605-11. PubMed ID: 17523160
    [No Abstract]   [Full Text] [Related]  

  • 18. Current applications of fetal cardiac imaging technology.
    Deng J; Rodeck CH
    Curr Opin Obstet Gynecol; 2006 Apr; 18(2):177-84. PubMed ID: 16601479
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of normal fetal pulmonary veins using B-flow imaging with spatiotemporal image correlation and by traditional color Doppler echocardiography.
    Zhang Y; Ding C; Fan M; Ren W; Guo Y; Sun W; Cai A
    Prenat Diagn; 2012 Dec; 32(12):1186-91. PubMed ID: 23044982
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Three- and four-dimensional freehand fetal echocardiography: a feasibility study using a hand-held Doppler probe for cardiac gating.
    Herberg U; Goldberg H; Breuer J
    Ultrasound Obstet Gynecol; 2005 Apr; 25(4):362-71. PubMed ID: 15761914
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.