21. Direct imaging of bileaflet mechanical valve behavior in the tricuspid position. Ikeda K; Okazaki Y; Furukawa K; Ohtsubo S; Yunoki J; Natsuaki M; Itoh T Eur J Cardiothorac Surg; 2006 Jun; 29(6):1014-9. PubMed ID: 16675254 [TBL] [Abstract][Full Text] [Related]
22. Pressure and flow fields in the hinge region of bileaflet mechanical heart valves. Gao ZB; Hosein N; Dai FF; Hwang NH J Heart Valve Dis; 1999 Mar; 8(2):197-205. PubMed ID: 10224581 [TBL] [Abstract][Full Text] [Related]
23. Prototype anionic detergent technique used to decellularize allograft valve conduits evaluated in the right ventricular outflow tract in sheep. Hilbert SL; Yanagida R; Souza J; Wolfinbarger L; Jones AL; Krueger P; Stearns G; Bert A; Hopkins RA J Heart Valve Dis; 2004 Sep; 13(5):831-40. PubMed ID: 15473487 [TBL] [Abstract][Full Text] [Related]
24. New insights in minimally invasive valve replacement: description of a cooperative approach for the off-pump replacement of mitral valves. Boudjemline Y; Pineau E; Borenstein N; Behr L; Bonhoeffer P Eur Heart J; 2005 Oct; 26(19):2013-7. PubMed ID: 15872031 [TBL] [Abstract][Full Text] [Related]
25. [A new design of bileaflet heart valve to eliminate the blood flow disturbance]. Zhang Z; Wang Y Zhongguo Yi Liao Qi Xie Za Zhi; 1999 Sep; 23(5):249-51, 257. PubMed ID: 12583067 [TBL] [Abstract][Full Text] [Related]
26. Bioprosthetic tissue calcification: influence of blood contact and arterial pressure. an experimental study in rats and sheep. Meuris B; Ozaki S; Herijgers P; Verbeken E; Flameng W J Heart Valve Dis; 2003 May; 12(3):392-9; discussion 399. PubMed ID: 12803341 [TBL] [Abstract][Full Text] [Related]
27. Evaluation of an in-vitro thrombosis assessment procedure by application to the Medtronic Parallel and St. Jude Medical valves. Martin AJ; Christy JR J Heart Valve Dis; 2004 Jul; 13(4):667-75. PubMed ID: 15311876 [TBL] [Abstract][Full Text] [Related]
28. Prevention of device-related tissue damage during percutaneous deployment of tissue-engineered heart valves. Stock UA; Degenkolbe I; Attmann T; Schenke-Layland K; Freitag S; Lutter G J Thorac Cardiovasc Surg; 2006 Jun; 131(6):1323-30. PubMed ID: 16733165 [TBL] [Abstract][Full Text] [Related]
29. Histological evaluation of tissue-engineered heart valves implanted in the juvenile sheep model: is there a need for in-vitro seeding? Dohmen PM; da Costa F; Yoshi S; Lopes SV; da Souza FP; Vilani R; Wouk AF; da Costa M; Konertz W J Heart Valve Dis; 2006 Nov; 15(6):823-9. PubMed ID: 17152791 [TBL] [Abstract][Full Text] [Related]
30. Percutaneous heart valve replacement: histology and calcification characteristics of biological valved stents in juvenile sheep. Attmann T; Quaden R; Freistedt A; König C; Cremer J; Lutter G Cardiovasc Pathol; 2007; 16(3):165-70. PubMed ID: 17502246 [TBL] [Abstract][Full Text] [Related]
31. Decellularization does not eliminate thrombogenicity and inflammatory stimulation in tissue-engineered porcine heart valves. Kasimir MT; Rieder E; Seebacher G; Nigisch A; Dekan B; Wolner E; Weigel G; Simon P J Heart Valve Dis; 2006 Mar; 15(2):278-86; discussion 286. PubMed ID: 16607912 [TBL] [Abstract][Full Text] [Related]
32. Influence of design and fixation pressure on fibrous sheathing in right-sided porcine aortic bioprostheses. Ozaki S; Herijgers P; Verbeken E; Meuris B; Ypermann J; Flameng W Semin Thorac Cardiovasc Surg; 2001 Oct; 13(4 Suppl 1):1-6. PubMed ID: 11805941 [TBL] [Abstract][Full Text] [Related]
33. Significance of spatial orientation of percutaneously placed bioprosthetic venous valves in an ovine model. Pavcnik D; Kaufman JA; Uchida BT; Case B; Correa LO; Goktay AY; Hamada A; Keller FS; Rösch J J Vasc Interv Radiol; 2005 Nov; 16(11):1511-6. PubMed ID: 16319159 [TBL] [Abstract][Full Text] [Related]
34. Hydrodynamic characteristics of bileaflet mechanical heart valves in an artificial heart: cavitation and closing velocity. Lee H; Homma A; Taenaka Y Artif Organs; 2007 Jul; 31(7):532-7. PubMed ID: 17584477 [TBL] [Abstract][Full Text] [Related]
35. Acoustical analysis of mechanical heart valve sounds for early detection of malfunction. Famaey N; Defever K; Bielen P; Flameng W; Vander Sloten J; Sas P; Meuris B Med Eng Phys; 2010 Oct; 32(8):934-9. PubMed ID: 20573536 [TBL] [Abstract][Full Text] [Related]
36. Durability of hand-sewn valves in the right ventricular outlet. Nunn GR; Bennetts J; Onikul E J Thorac Cardiovasc Surg; 2008 Aug; 136(2):290-6. PubMed ID: 18692631 [TBL] [Abstract][Full Text] [Related]
37. Mechanical and morphological study of biostable polyurethane heart valve leaflets explanted from sheep. Bernacca GM; Straub I; Wheatley DJ J Biomed Mater Res; 2002 Jul; 61(1):138-45. PubMed ID: 12001256 [TBL] [Abstract][Full Text] [Related]