These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

207 related articles for article (PubMed ID: 15704846)

  • 1. [Study of the impact of the number of distal locking bolts on the biomechanical feature of locking intramedullary nails].
    Gong F; Wang K; Dang X; Wang L
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2005 Jan; 19(1):58-60. PubMed ID: 15704846
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of one versus two distal locking bolts on the biomechanics of tibial interlocking nail: a comparative study using a new model.
    Gong FL; Wang KZ; Dang XQ; Wang CS; Shi ZB
    Di Yi Jun Yi Da Xue Xue Bao; 2005 May; 25(5):488-92. PubMed ID: 15897116
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [A biomechanical study on internal and external fixation devices for treatment of humeral shaft fracture].
    Niu X; Huang F; Cen S; Qin T; Wang R; Shang Z; Liu A; Zheng H
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 May; 22(5):516-9. PubMed ID: 18630425
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Biomechanical study on rotating-arm self-locking intramedullary nail in the treatment of tibial shaft fracture].
    Fang Y; Guo H; Chi L; Wang G; Yang T
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2004 Dec; 21(6):970-3. PubMed ID: 15646344
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Factors influencing interlocking screw failure in unreamed small diameter nails--a biomechanical study using a distal tibia fracture model.
    Weninger P; Schueller M; Jamek M; Stanzl-Tschegg S; Redl H; Tschegg EK
    Clin Biomech (Bristol, Avon); 2009 May; 24(4):379-84. PubMed ID: 19231049
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Angular stability potentially permits fewer locking screws compared with conventional locking in intramedullary nailed distal tibia fractures: a biomechanical study.
    Gueorguiev B; Ockert B; Schwieger K; Wähnert D; Lawson-Smith M; Windolf M; Stoffel K
    J Orthop Trauma; 2011 Jun; 25(6):340-6. PubMed ID: 21577069
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fracture strain and stability with additional locking screws in intramedullary nailing: a biomechanical study.
    Sayana MK; Davis BJ; Kapoor B; Rahmatalla A; Maffulli N
    J Trauma; 2006 May; 60(5):1053-7. PubMed ID: 16688070
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomechanical analysis of retrograde intramedullary nail fixation in distal femoral fractures.
    Chen SH; Yu TC; Chang CH; Lu YC
    Knee; 2008 Oct; 15(5):384-9. PubMed ID: 18722126
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fatigue load of current tibial intramedullary nail designs: a simulated study.
    Wagner M; Liu Q; Ellis TJ
    Orthopedics; 2011 Jun; 34(6):195. PubMed ID: 21667907
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Distal femoral fixation: a biomechanical comparison of trigen retrograde intramedullary (i.m.) nail, dynamic condylar screw (DCS), and locking compression plate (LCP) condylar plate.
    Heiney JP; Barnett MD; Vrabec GA; Schoenfeld AJ; Baji A; Njus GO
    J Trauma; 2009 Feb; 66(2):443-9. PubMed ID: 19204519
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Biomechanical evaluation of nickel-titanium shape-memory alloy enclosed interlocking intramedular nail].
    Cao YM; Zhao WD; Zhang MC; Bao K; Da GZ
    Nan Fang Yi Ke Da Xue Xue Bao; 2006 May; 26(5):584-6. PubMed ID: 16762855
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparison of the torsional performance of stainless steel and titanium alloy tibial intramedullary nails: a clinically relevant approach.
    Aitchison GA; Johnstone AJ; Shepherd DE; Watson MA
    Biomed Mater Eng; 2004; 14(3):235-40. PubMed ID: 15299235
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [The biomechanical study of rotating-arm self-locking intramedullary nails in comminuted femoral shaft fractures].
    Fang Y; Fu X; Chi L; Wang G; Yang T
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Oct; 23(5):1041-4. PubMed ID: 17121350
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mechanics of intramedullary nails for femoral fractures.
    Johnson KD; Tencer A
    Unfallchirurg; 1990 Nov; 93(11):506-11. PubMed ID: 2270493
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Micromotion at the fracture site after tibial nailing with four unreamed small-diameter nails--a biomechanical study using a distal tibia fracture model.
    Schüller M; Weninger P; Tschegg E; Jamek M; Redl H; Stanzl-Tschegg S
    J Trauma; 2009 May; 66(5):1391-7. PubMed ID: 19430244
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Introduction of a new interlocked intramedullary nailing device for stabilization of critically sized femoral defects in the rat: A combined biomechanical and animal experimental study.
    Schoen M; Rotter R; Schattner S; Mittlmeier T; Claes L; Vollmar B; Gradl G
    J Orthop Res; 2008 Feb; 26(2):184-9. PubMed ID: 17868113
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical comparison of a 2 and 3 proximal screw-configured antegrade piriformis intramedullary nail with a trochanteric reconstruction nail in an unstable subtrochanteric fracture model.
    Fissel B; Moed BR; Bledsoe JG
    J Orthop Trauma; 2008; 22(5):337-41. PubMed ID: 18448988
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Improving the distal fixation of intramedullary nails in osteoporotic bone.
    Kummer FJ; Koval KJ; Kauffman JI
    Bull Hosp Jt Dis; 1997; 56(2):88-90. PubMed ID: 9220097
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Biomechanical test of intramedullary controlled dynamic nailing].
    Wang G; Peng X; Wang J; Pan T
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Jun; 22(6):703-6. PubMed ID: 18630568
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Increasing nail-cortical contact to increase fixation stability and decrease implant strain in antegrade locked nailing of distal femoral fractures: a biomechanical study.
    Huang SC; Lin CC; Lin J
    J Trauma; 2009 Feb; 66(2):436-42. PubMed ID: 19065112
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.