These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

196 related articles for article (PubMed ID: 15705507)

  • 21. Combined passive and active shimming for in vivo MR spectroscopy at high magnetic fields.
    Juchem C; Muller-Bierl B; Schick F; Logothetis NK; Pfeuffer J
    J Magn Reson; 2006 Dec; 183(2):278-89. PubMed ID: 17011219
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A new EPI-based dynamic field mapping method: application to retrospective geometrical distortion corrections.
    Lamberton F; Delcroix N; Grenier D; Mazoyer B; Joliot M
    J Magn Reson Imaging; 2007 Sep; 26(3):747-55. PubMed ID: 17729370
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Diffusion-weighted echo planar MR imaging of the neck at 3 T using integrated shimming: comparison of MR sequence techniques for reducing artifacts caused by magnetic-field inhomogeneities.
    Gatidis S; Graf H; Weiß J; Stemmer A; Kiefer B; Nikolaou K; Notohamiprodjo M; Martirosian P
    MAGMA; 2017 Feb; 30(1):57-63. PubMed ID: 27503308
    [TBL] [Abstract][Full Text] [Related]  

  • 24. High-resolution fMRI with higher-order generalized series imaging and parallel imaging techniques (HGS-parallel).
    Yun S; Oh SS; Han Y; Park H
    J Magn Reson Imaging; 2009 Apr; 29(4):924-36. PubMed ID: 19306432
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Reducing image artefacts in concurrent TMS/fMRI by passive shimming.
    Bungert A; Chambers CD; Phillips M; Evans CJ
    Neuroimage; 2012 Feb; 59(3):2167-74. PubMed ID: 22019878
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Susceptibility-matched envelope for the correction of EPI artifacts.
    Neufeld A; Assaf Y; Graif M; Hendler T; Navon G
    Magn Reson Imaging; 2005 Nov; 23(9):947-51. PubMed ID: 16310110
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A method of generalized projections (MGP) ghost correction algorithm for interleaved EPI.
    Lee KJ; Papadakis NG; Barber DC; Wilkinson ID; Griffiths PD; Paley MN
    IEEE Trans Med Imaging; 2004 Jul; 23(7):839-48. PubMed ID: 15250636
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Integrated parallel reception, excitation, and shimming (iPRES) with multiple shim loops per radio-frequency coil element for improved B
    Darnell D; Truong TK; Song AW
    Magn Reson Med; 2017 May; 77(5):2077-2086. PubMed ID: 27174387
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Joint estimation and correction of geometric distortions for EPI functional MRI using harmonic retrieval.
    Nguyen HM; Sutton BP; Morrison RL; Do MN
    IEEE Trans Med Imaging; 2009 Mar; 28(3):423-34. PubMed ID: 19244014
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Surface-based functional magnetic resonance imaging analysis of partial brain echo planar imaging data at 1.5 T.
    Jo HJ; Lee JM; Kim JH; Choi CH; Kang DH; Kwon JS; Kim SI
    Magn Reson Imaging; 2009 Jun; 27(5):691-700. PubMed ID: 19036544
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Doubling the resolution of echo-planar brain imaging by acquisition of two k-space lines per gradient reversal using TRAIL.
    Priest AN; De Vita E; Ordidge RJ
    NMR Biomed; 2008 Feb; 21(2):79-88. PubMed ID: 17506114
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A single-scan T2* mapping method based on two gradient-echo images with compensation for macroscopic field inhomogeneity.
    Meng Y; Lei H
    Magn Reson Med; 2008 Dec; 60(6):1388-95. PubMed ID: 19025905
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A 32-channel multi-coil setup optimized for human brain shimming at 9.4T.
    Aghaeifar A; Zhou J; Heule R; Tabibian B; Schölkopf B; Jia F; Zaitsev M; Scheffler K
    Magn Reson Med; 2020 Feb; 83(2):749-764. PubMed ID: 31483527
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Real-time autoshimming for echo planar timecourse imaging.
    Ward HA; Riederer SJ; Jack CR
    Magn Reson Med; 2002 Nov; 48(5):771-80. PubMed ID: 12417991
    [TBL] [Abstract][Full Text] [Related]  

  • 35. High-fidelity, high-isotropic-resolution diffusion imaging through gSlider acquisition with
    Liao C; Stockmann J; Tian Q; Bilgic B; Arango NS; Manhard MK; Huang SY; Grissom WA; Wald LL; Setsompop K
    Magn Reson Med; 2020 Jan; 83(1):56-67. PubMed ID: 31373048
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Single, slice-specific z-shim gradient pulses improve T2*-weighted imaging of the spinal cord.
    Finsterbusch J; Eippert F; Büchel C
    Neuroimage; 2012 Feb; 59(3):2307-15. PubMed ID: 21979381
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Short-scan-time multi-slice diffusion MRI of the mouse cervical spinal cord using echo planar imaging.
    Callot V; Duhamel G; Cozzone PJ; Kober F
    NMR Biomed; 2008 Oct; 21(8):868-77. PubMed ID: 18574855
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Spiral imaging: a critical appraisal.
    Block KT; Frahm J
    J Magn Reson Imaging; 2005 Jun; 21(6):657-68. PubMed ID: 15906329
    [TBL] [Abstract][Full Text] [Related]  

  • 39. DYNAmic Multi-coIl TEchnique (DYNAMITE) shimming of the rat brain at 11.7 T.
    Juchem C; Herman P; Sanganahalli BG; Brown PB; McIntyre S; Nixon TW; Green D; Hyder F; de Graaf RA
    NMR Biomed; 2014 Aug; 27(8):897-906. PubMed ID: 24839167
    [TBL] [Abstract][Full Text] [Related]  

  • 40. On the synchronization of transcranial magnetic stimulation and functional echo-planar imaging.
    Bestmann S; Baudewig J; Frahm J
    J Magn Reson Imaging; 2003 Mar; 17(3):309-16. PubMed ID: 12594720
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.