These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 15711976)

  • 21. The Ability of esCCO and ECOM Monitors to Measure Trends in Cardiac Output During Alveolar Recruitment Maneuver After Cardiac Surgery: A Comparison with the Pulmonary Thermodilution Method.
    Thonnerieux M; Alexander B; Binet C; Obadia JF; Bastien O; Desebbe O
    Anesth Analg; 2015 Aug; 121(2):383-91. PubMed ID: 25902321
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Cardiac output monitoring by pressure recording analytical method in cardiac surgery.
    Giomarelli P; Biagioli B; Scolletta S
    Eur J Cardiothorac Surg; 2004 Sep; 26(3):515-20. PubMed ID: 15302045
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Clinicians' abilities to estimate cardiac index in ventilated children and infants.
    Tibby SM; Hatherill M; Marsh MJ; Murdoch IA
    Arch Dis Child; 1997 Dec; 77(6):516-8. PubMed ID: 9496187
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effect of peritoneal dialysis on intra-abdominal pressure and cardio-respiratory function in infants following cardiac surgery.
    Morris KP; Butt WW; Karl TR
    Cardiol Young; 2004 Jun; 14(3):293-8. PubMed ID: 15680023
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Measurement of cardiac output after cardiac surgery by a new transesophageal Doppler device.
    Jaeggi P; Hofer CK; Klaghofer R; Fodor P; Genoni M; Zollinger A
    J Cardiothorac Vasc Anesth; 2003 Apr; 17(2):217-20. PubMed ID: 12698405
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Comparison of ICG thoracic bioimpedance cardiac output monitoring system in patients undergoing cardiac surgery with pulmonary artery cardiac output measurements].
    Simon R; Desebbe O; Hénaine R; Bastien O; Lehot JJ; Cannesson M
    Ann Fr Anesth Reanim; 2009 Jun; 28(6):537-41. PubMed ID: 19525086
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [The usefulness of bioimpedance in patient monitoring in an intensive-therapy heart-surgery unit: a comparison with thermodilution].
    Ferraro S; D'Alto M; Maddalena G; Golino A; Liguori L; Jannelli G; Spampinato N; Chiariello M
    Cardiologia; 1993 Sep; 38(9):577-83. PubMed ID: 8287387
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Effect of the venous catheter site on transpulmonary thermodilution measurement variables.
    Schmidt S; Westhoff TH; Hofmann C; Schaefer JH; Zidek W; Compton F; van der Giet M
    Crit Care Med; 2007 Mar; 35(3):783-6. PubMed ID: 17255873
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Strong relationship between NT-proXNP levels and cardiac output following cardiac surgery in neonates and infants.
    Breuer T; Skoumal R; Horkay F; Merkely B; Ala-Kopsala M; Leppäluoto J; Vuolteenaho O; Ruskoaho H; Tóth M; Székely A
    Acta Anaesthesiol Scand; 2010 Apr; 54(4):502-9. PubMed ID: 19919584
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Cardiac Output Measurement With Echocardiography and Pressure Recording Analytical Method in Pediatric Patients Admitted to the Cardiac Intensive Care Unit: A Retrospective Assessment of Bias Between the Two Methods.
    Ricci Z; Cecconi G; Lillo R; Di Chiara L; Toscano A; Iacobelli R
    J Cardiothorac Vasc Anesth; 2021 May; 35(5):1351-1357. PubMed ID: 33376069
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Near-infrared spectroscopy after high-risk congenital heart surgery in the paediatric intensive care unit.
    Tume LN; Arnold P
    Cardiol Young; 2015 Mar; 25(3):459-67. PubMed ID: 24521519
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Cardiac output measured by a new arterial pressure waveform analysis method without calibration compared with thermodilution after cardiac surgery.
    Breukers RM; Sepehrkhouy S; Spiegelenberg SR; Groeneveld AB
    J Cardiothorac Vasc Anesth; 2007 Oct; 21(5):632-5. PubMed ID: 17905265
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Evaluation on the early hemodynamic changes after cardiac surgery for congenital heart diseases in neonates].
    Qiu LS; Liu JF; Zhu LM; Xu ZM
    Zhonghua Er Ke Za Zhi; 2009 Sep; 47(9):662-6. PubMed ID: 20021787
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Evaluation of a new invasive continuous cardiac output monitoring system: the truCCOMS system.
    Thierry S; Thebert D; Brocas E; Razzaghi F; Van De Louw A; Loisance D; Teboul JL
    Intensive Care Med; 2003 Nov; 29(11):2096-9. PubMed ID: 13680117
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Noninvasive cardiac output measurement using bioreactance in postoperative pediatric patients.
    Vergnaud E; Vidal C; Verchere JM; Taright H; Meyer PG; Carli PA; Orliaguet GA
    Paediatr Anaesth; 2015 Feb; 25(2):160-6. PubMed ID: 24814690
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Predictive power of serum cystatin C to detect acute kidney injury and pediatric-modified RIFLE class in children undergoing cardiac surgery.
    Hassinger AB; Backer CL; Lane JC; Haymond S; Wang D; Wald EL
    Pediatr Crit Care Med; 2012 Jul; 13(4):435-40. PubMed ID: 22596066
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Validation of a new arterial pulse contour-based cardiac output device.
    de Waal EE; Kalkman CJ; Rex S; Buhre WF
    Crit Care Med; 2007 Aug; 35(8):1904-9. PubMed ID: 17581493
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Pediatric Index of Cardiac Surgical Intensive Care Mortality Risk Score for Pediatric Cardiac Critical Care.
    Jeffries HE; Soto-Campos G; Katch A; Gall C; Rice TB; Wetzel R
    Pediatr Crit Care Med; 2015 Nov; 16(9):846-52. PubMed ID: 26196254
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Assessment of cardiac output in children: a comparison between the pressure recording analytical method and Doppler echocardiography.
    Calamandrei M; Mirabile L; Muschetta S; Gensini GF; De Simone L; Romano SM
    Pediatr Crit Care Med; 2008 May; 9(3):310-2. PubMed ID: 18446106
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Skin temperature as a noninvasive marker of haemodynamic and perfusion status in adult cardiac surgical patients: an observational study.
    Schey BM; Williams DY; Bucknall T
    Intensive Crit Care Nurs; 2009 Feb; 25(1):31-7. PubMed ID: 18621531
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.