These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

197 related articles for article (PubMed ID: 15717154)

  • 21. Assessment of pacing maneuvers used to validate anterograde accessory pathway potentials.
    Niebauer MJ; Daoud E; Goyal R; Harvey M; Castellani M; Bogun F; Chan KK; Man KC; Strickberger A; Morady F
    J Cardiovasc Electrophysiol; 1995 May; 6(5):350-6. PubMed ID: 7551303
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A feasible approach for direct his-bundle pacing using a new steerable catheter to facilitate precise lead placement.
    Zanon F; Baracca E; Aggio S; Pastore G; Boaretto G; Cardano P; Marotta T; Rigatelli G; Galasso M; Carraro M; Zonzin P
    J Cardiovasc Electrophysiol; 2006 Jan; 17(1):29-33. PubMed ID: 16426396
    [TBL] [Abstract][Full Text] [Related]  

  • 23. His bundle pacing: Initial experience and lessons learned.
    Deshmukh A; Deshmukh P
    J Electrocardiol; 2016; 49(5):658-63. PubMed ID: 27591359
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Permanent His-bundle pacing is feasible, safe, and superior to right ventricular pacing in routine clinical practice.
    Sharma PS; Dandamudi G; Naperkowski A; Oren JW; Storm RH; Ellenbogen KA; Vijayaraman P
    Heart Rhythm; 2015 Feb; 12(2):305-12. PubMed ID: 25446158
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Reanalysis of the "pseudo A-A-V" response to ventricular entrainment of supraventricular tachycardia: importance of his-bundle timing.
    Vijayaraman P; Lee BP; Kalahasty G; Wood MA; Ellenbogen KA
    J Cardiovasc Electrophysiol; 2006 Jan; 17(1):25-8. PubMed ID: 16426395
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Paradoxical increase of stimulus to atrium interval despite His-bundle capture during para-Hisian pacing.
    van Opstal JM; Crijns HJ
    Europace; 2009 Dec; 11(12):1702-4. PubMed ID: 19700778
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Rate stabilization by right ventricular apex or His bundle pacing in patients with atrial fibrillation.
    Padeletti L; Fantini F; Michelucci A; Pieragnoli P; Colella A; Musilli N; Ricciardi G; Buhr TA; Valsecchi S
    Europace; 2005 Sep; 7(5):454-9. PubMed ID: 16087109
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Failure to recognize a His bundle potential in complete atrioventricular block.
    Lane GK; Kennelly BM
    Eur J Cardiol; 1979 Jul; 10(1):71-5. PubMed ID: 467484
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Normalization of bundle branch block patterns by distal His bundle pacing. Clinical and experimental evidence of longitudinal dissociation in the pathologic his bundle.
    El-Sherif N; Amay-Y-Leon F; Schonfield C; Scherlag BJ; Rosen K; Lazzara R; Wyndham C
    Circulation; 1978 Mar; 57(3):473-83. PubMed ID: 624157
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Cycle length criteria for His-bundle capture are capable of determining pacing types misclassified by output criteria.
    Liang Y; Yu H; Wang N; Liang Z; Xu B; Gao Y; Cha YM; Wang Z; Han Y
    Heart Rhythm; 2019 Nov; 16(11):1629-1635. PubMed ID: 31096063
    [TBL] [Abstract][Full Text] [Related]  

  • 31. His-bundle electrogram in the convalescent stage of inferior myocardial infarction complicated with complete A-V block.
    Aizawa Y; Hayashi S; Hosokawa O; Watanabe K; Ozawa T; Shibata A; Takeuchi Y
    J Electrocardiol; 1982 Apr; 15(2):127-30. PubMed ID: 7069328
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Reinitiation of ventricular macroreentry within the His-Purkinje system by back-up ventricular pacing - a mechanism of ventricular tachycardia storm.
    Reithmann C; Hahnefeld A; Oversohl N; Ulbrich M; Remp T; Steinbeck G
    Pacing Clin Electrophysiol; 2007 Feb; 30(2):225-35. PubMed ID: 17338720
    [TBL] [Abstract][Full Text] [Related]  

  • 33. His overdrive pacing during supraventricular tachycardia: a novel maneuver for distinguishing atrioventricular nodal reentrant tachycardia from atrioventricular reciprocating tachycardia.
    Singh DK; Viswanathan MN; Tanel RE; Lee RJ; Lee BK; Marcus GM; Olgin JE; Han F; Vedantham V; Tseng ZH; Pellegrini C; Kawamura M; Gerstenfeld EP; Badhwar N; Scheinman M
    Heart Rhythm; 2014 Aug; 11(8):1327-35. PubMed ID: 24793458
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Frequency-dependent effects of quinidine on the ventricular action potential and QRS duration in humans.
    Nademanee K; Stevenson WG; Weiss JN; Frame VB; Antimisiaris MG; Suithichaiyakul T; Pruitt CM
    Circulation; 1990 Mar; 81(3):790-6. PubMed ID: 2306831
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Electrical parameters with His-bundle pacing: Considerations for automated programming.
    Starr N; Dayal N; Domenichini G; Stettler C; Burri H
    Heart Rhythm; 2019 Dec; 16(12):1817-1824. PubMed ID: 31377421
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Permanent His-bundle pacing: seeking physiological ventricular pacing.
    Barba-Pichardo R; Moriña-Vázquez P; Fernández-Gómez JM; Venegas-Gamero J; Herrera-Carranza M
    Europace; 2010 Apr; 12(4):527-33. PubMed ID: 20338988
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Programmed deep septal stimulation: A novel maneuver for the diagnosis of left bundle branch capture during permanent pacing.
    Jastrzębski M; Moskal P; Bednarek A; Kiełbasa G; Kusiak A; Sondej T; Bednarski A; Vijayaraman P; Czarnecka D
    J Cardiovasc Electrophysiol; 2020 Feb; 31(2):485-493. PubMed ID: 31930753
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Variability in the measurement of human ventricular refractoriness.
    Kadish AH; Schmaltz S; Morady F
    Pacing Clin Electrophysiol; 1991 Sep; 14(9):1393-401. PubMed ID: 1720533
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The effect of digitalis on refractoriness of the intact canine His-Purkinje system.
    Gomes JA; Damato AN; Bobb GA; Lau SH
    Circulation; 1978 Aug; 58(2):284-94. PubMed ID: 668077
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Experimental His-bundle pacing: histopathological and electrophysiological examination.
    Amitani S; Miyahara K; Sohara H; Kakura H; Koga M; Moriyama Y; Taira A; Nagano S; Miura N; Misumi K; Sakamoto H
    Pacing Clin Electrophysiol; 1999 Apr; 22(4 Pt 1):562-6. PubMed ID: 10234709
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.