These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
140 related articles for article (PubMed ID: 15719974)
21. An endoluminal cylindrical sectored-ring ultrasound phased-array applicator for minimally-invasive therapeutic ultrasound. Zubair M; Adams MS; Diederich CJ Med Phys; 2023 Jan; 50(1):1-19. PubMed ID: 36413363 [TBL] [Abstract][Full Text] [Related]
22. A system for the simultaneous delivery of intraoperative radiation and ultrasound hyperthermia. Montes H; Hynynen K Int J Hyperthermia; 1995; 11(1):109-19. PubMed ID: 7714364 [TBL] [Abstract][Full Text] [Related]
23. Characteristics and performance evaluation of the capacitive Contact Flexible Microstrip Applicator operating at 70 MHz for external hyperthermia. van Wieringen N; Wiersma J; Zum Vörde Sive Vörding P; Oldenborg S; Gelvich EA; Mazokhin VN; van Dijk JD; Crezee J Int J Hyperthermia; 2009 Nov; 25(7):542-53. PubMed ID: 19848617 [TBL] [Abstract][Full Text] [Related]
24. Method for MRI-guided conformal thermal therapy of prostate with planar transurethral ultrasound heating applicators. Chopra R; Burtnyk M; Haider MA; Bronskill MJ Phys Med Biol; 2005 Nov; 50(21):4957-75. PubMed ID: 16237234 [TBL] [Abstract][Full Text] [Related]
25. A new high intensity focused ultrasound applicator for surgical applications. Brentnall MD; Martin RW; Vaezy S; Kaczkowski P; Forster F; Crum L IEEE Trans Ultrason Ferroelectr Freq Control; 2001 Jan; 48(1):53-63. PubMed ID: 11367806 [TBL] [Abstract][Full Text] [Related]
26. Development and evaluation of a three-dimensional hyperthermia applicator with Water-COated Antennas (WACOA). Nadobny J; Wlodarczyk W; Westhoff L; Gellermann J; Rau B; Mönich G; Wust P Med Phys; 2003 Aug; 30(8):2052-64. PubMed ID: 12945971 [TBL] [Abstract][Full Text] [Related]
27. [Design of an microwave applicator using for tumor in superficial layer]. Sun B; Lu X; Cao Y Zhongguo Yi Liao Qi Xie Za Zhi; 2010 May; 34(3):198-201. PubMed ID: 20812645 [TBL] [Abstract][Full Text] [Related]
28. Design of a fast multileaf collimator for radiobiological optimized IMRT with scanned beams of photons, electrons, and light ions. Svensson R; Larsson S; Gudowska I; Holmberg R; Brahme A Med Phys; 2007 Mar; 34(3):877-88. PubMed ID: 17441233 [TBL] [Abstract][Full Text] [Related]
30. [A multifrequency phase-controlled driving system for ultrasound therapy]. Dai QJ; Zhou QW; Xu XZ; Ou Yang KY; Bian ZZ Zhongguo Yi Liao Qi Xie Za Zhi; 2002 Jul; 26(4):256-8. PubMed ID: 16104277 [TBL] [Abstract][Full Text] [Related]
31. Intraluminal ultrasound applicator compatible with magnetic resonance imaging "real-time" temperature mapping for the treatment of oesophageal tumours: an ex vivo study. Melodelima D; Salomir R; Mougenot C; Prat F; Theillère Y; Moonen C; Cathignol D Med Phys; 2004 Feb; 31(2):236-44. PubMed ID: 15000609 [TBL] [Abstract][Full Text] [Related]
32. Treatable domain and optimal frequency for brain tumors during ultrasound hyperthermia. Lin WL; Liauh CT; Yen JY; Chen YY; Shieh MJ Int J Radiat Oncol Biol Phys; 2000 Jan; 46(1):239-47. PubMed ID: 10656398 [TBL] [Abstract][Full Text] [Related]
33. Development of scanned focussed ultrasound hyperthermia: clinical response evaluation. Harari PM; Hynynen KH; Roemer RB; Anhalt DP; Shimm DS; Stea B; Cassady JR Int J Radiat Oncol Biol Phys; 1991 Aug; 21(3):831-40. PubMed ID: 1869473 [TBL] [Abstract][Full Text] [Related]
34. Multisectored interstitial ultrasound applicators for dynamic angular control of thermal therapy. Kinsey AM; Diederich CJ; Tyreus PD; Nau WH; Rieke V; Pauly KB Med Phys; 2006 May; 33(5):1352-63. PubMed ID: 16752571 [TBL] [Abstract][Full Text] [Related]
35. The design and characterization of an ultrasound phased array suitable for deep tissue hyperthermia. Aitkenhead AH; Mills JA; Wilson AJ Ultrasound Med Biol; 2008 Nov; 34(11):1793-807. PubMed ID: 18571831 [TBL] [Abstract][Full Text] [Related]
36. Techniques for intraoperative hyperthermia with ultrasound: the Dartmouth experience with 19 patients. Ryan TP; Colacchio TA; Douple EB; Strohbehn JW; Coughlin CT Int J Hyperthermia; 1992; 8(4):407-21. PubMed ID: 1402123 [TBL] [Abstract][Full Text] [Related]
37. Analysis and testing of a concentric ring applicator for ultrasound hyperthermia with clinical results. Ryan TP; Hartov A; Colacchio TA; Coughlin CT; Stafford JH; Hoopes PJ Int J Hyperthermia; 1991; 7(4):587-603. PubMed ID: 1919154 [TBL] [Abstract][Full Text] [Related]
38. [System design of small intellectualized ultrasound hyperthermia instrument in the LabVIEW environment]. Jiang F; Bai J; Chen Y Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2005 Aug; 22(4):836-9. PubMed ID: 16156285 [TBL] [Abstract][Full Text] [Related]
39. Deployable cylindrical phased-array applicator mimicking a concentric-ring configuration for minimally-invasive delivery of therapeutic ultrasound. Adams MS; Diederich CJ Phys Med Biol; 2019 Jun; 64(12):125001. PubMed ID: 31108478 [TBL] [Abstract][Full Text] [Related]
40. Design and experimental evaluation of an intracavitary ultrasound phased array system for hyperthermia. Buchanan MT; Hynynen K IEEE Trans Biomed Eng; 1994 Dec; 41(12):1178-87. PubMed ID: 7851919 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]