These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. PCR microfluidic devices for DNA amplification. Zhang C; Xu J; Ma W; Zheng W Biotechnol Adv; 2006; 24(3):243-84. PubMed ID: 16326063 [TBL] [Abstract][Full Text] [Related]
5. Polydimethylsiloxane-LiNbO3 surface acoustic wave micropump devices for fluid control into microchannels. Girardo S; Cecchini M; Beltram F; Cingolani R; Pisignano D Lab Chip; 2008 Sep; 8(9):1557-63. PubMed ID: 18818813 [TBL] [Abstract][Full Text] [Related]
6. Continuous-flow polymerase chain reaction of single-copy DNA in microfluidic microdroplets. Schaerli Y; Wootton RC; Robinson T; Stein V; Dunsby C; Neil MA; French PM; Demello AJ; Abell C; Hollfelder F Anal Chem; 2009 Jan; 81(1):302-6. PubMed ID: 19055421 [TBL] [Abstract][Full Text] [Related]
7. Microchamber array based DNA quantification and specific sequence detection from a single copy via PCR in nanoliter volumes. Matsubara Y; Kerman K; Kobayashi M; Yamamura S; Morita Y; Tamiya E Biosens Bioelectron; 2005 Feb; 20(8):1482-90. PubMed ID: 15626601 [TBL] [Abstract][Full Text] [Related]
8. Parallel picoliter rt-PCR assays using microfluidics. Marcus JS; Anderson WF; Quake SR Anal Chem; 2006 Feb; 78(3):956-8. PubMed ID: 16448074 [TBL] [Abstract][Full Text] [Related]
9. Real time PCR on disposable PDMS chip with a miniaturized thermal cycler. Xiang Q; Xu B; Fu R; Li D Biomed Microdevices; 2005 Dec; 7(4):273-9. PubMed ID: 16404505 [TBL] [Abstract][Full Text] [Related]
11. Ultrasonic standing wave manipulation technology integrated into a dielectrophoretic chip. Wiklund M; Günther C; Lemor R; Jäger M; Fuhr G; Hertz HM Lab Chip; 2006 Dec; 6(12):1537-44. PubMed ID: 17203158 [TBL] [Abstract][Full Text] [Related]
12. Integration of a surface acoustic wave biosensor in a microfluidic polymer chip. Länge K; Blaess G; Voigt A; Götzen R; Rapp M Biosens Bioelectron; 2006 Aug; 22(2):227-32. PubMed ID: 16458497 [TBL] [Abstract][Full Text] [Related]
13. Automated chip-based device for simple and fast nucleic acid amplification. Münchow G; Dadic D; Doffing F; Hardt S; Drese KS Expert Rev Mol Diagn; 2005 Jul; 5(4):613-20. PubMed ID: 16013978 [TBL] [Abstract][Full Text] [Related]
14. A chip-to-chip nanoliter microfluidic dispenser. Wang J; Zhou Y; Qiu H; Huang H; Sun C; Xi J; Huang Y Lab Chip; 2009 Jul; 9(13):1831-5. PubMed ID: 19532955 [TBL] [Abstract][Full Text] [Related]
15. A simple, valveless microfluidic sample preparation device for extraction and amplification of DNA from nanoliter-volume samples. Legendre LA; Bienvenue JM; Roper MG; Ferrance JP; Landers JP Anal Chem; 2006 Mar; 78(5):1444-51. PubMed ID: 16503592 [TBL] [Abstract][Full Text] [Related]
16. A palmtop PCR system with a disposable polymer chip operated by the thermosiphon effect. Chung KH; Park SH; Choi YH Lab Chip; 2010 Jan; 10(2):202-10. PubMed ID: 20066248 [TBL] [Abstract][Full Text] [Related]