BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

174 related articles for article (PubMed ID: 1572888)

  • 1. A nonsurgical technique for removal of a Swan-Ganz catheter entrapped in the right atrium.
    Petrilli G; Peranzoni PF; Barbieri E
    J Cardiovasc Surg (Torino); 1992; 33(2):251-2. PubMed ID: 1572888
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ventricular entrapment of a Swan-Ganz catheter: a technique for nonsurgical removal.
    Lazzam C; Sanborn TA; Christian F
    J Am Coll Cardiol; 1989 May; 13(6):1422-4. PubMed ID: 2649532
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Complications caused by a Swan-Ganz catheter. An inadvertent entrapment in the right atrium during cardiac surgery].
    Seitz W; Kaukemüller J; Frank G
    Anaesthesist; 1989 May; 38(5):259-61. PubMed ID: 2735522
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Non-surgical removal of a knotted Swan-Ganz catheter].
    Böttiger BW; Schmidt H; Böhrer H; Martin E
    Anaesthesist; 1991 Dec; 40(12):682-6. PubMed ID: 1781566
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transfemoral percutaneous removal of a knotted Swan-Ganz catheter.
    Katsikis A; Karavolias G; Voudris V
    Catheter Cardiovasc Interv; 2009 Nov; 74(5):802-4. PubMed ID: 19830792
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Successful nonsurgical removal of a knotted and entrapped pulmonary artery catheter.
    Mehta N; Lochab SS; Tempe DK; Trehan V; Nigam M
    Cathet Cardiovasc Diagn; 1998 Jan; 43(1):87-9. PubMed ID: 9473201
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A new technique for right heart catheterization with a Swan-Ganz balloon catheter via femoral vein in the patient with dilated right heart chambers, utilizing a modified transseptal-type sheath.
    Lee HH; Mahrer PR
    Cathet Cardiovasc Diagn; 1991 May; 23(1):54-6. PubMed ID: 1830829
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Percutaneous untying of a knot in a retained Swan-Ganz catheter.
    Bhatti WA; Sinha S; Rowlands P
    Cardiovasc Intervent Radiol; 2000; 23(3):224-5. PubMed ID: 10821898
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Retrieval of intravascular catheter fragment remaining for 15 years--a case report].
    Toda R; Yuda T; Nishida T; Yamauchi T; Toyohira H; Taira A
    Nihon Kyobu Geka Gakkai Zasshi; 1997 Jan; 45(1):51-4. PubMed ID: 9028124
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Entrapment of a Swan-Ganz catheter.
    Chen LC; Huang PH
    J Chin Med Assoc; 2007 May; 70(5):213-4. PubMed ID: 17524999
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Entrapment of pulmonary artery catheter in a suture at the inferior vena cava cannulation site.
    Huang L; Elsharydah A; Nawabi A; Cork RC
    J Clin Anesth; 2004 Nov; 16(7):557-9. PubMed ID: 15590265
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Snaring of a Swan-Ganz catheter.
    Block PC
    J Thorac Cardiovasc Surg; 1976 Jun; 71(6):917-9. PubMed ID: 775200
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Percutaneous unknotting and retrieval of Swan-Ganz catheter.
    Walser EM; Savage C; Ozkan O; Zwischenberger JB
    Ann Thorac Surg; 2003 Mar; 75(3):1027. PubMed ID: 12645746
    [No Abstract]   [Full Text] [Related]  

  • 14. [Transfemoral extraction of a knotted Swan-Ganz catheter using an F24 dilator].
    Alzen G; Wildberger J; Klinge U; Günther RW
    Anasthesiol Intensivmed Notfallmed Schmerzther; 1991 Aug; 26(5):280-2. PubMed ID: 1932452
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Inadvertent fracture during the attempted removal of entrapped Swan-Ganz catheter.
    Sezen M; Yavuz S; Goncu T; Eris C
    Ann Acad Med Singap; 2008 Nov; 37(11):984-5. PubMed ID: 19082211
    [No Abstract]   [Full Text] [Related]  

  • 16. [Entrapment of a Swan-Ganz catheter within the right pulmonary artery ligature during right pneumonectomy].
    Heves Karagöz A; Kanbak M; Celebioğlu B; Akinci SB; Kara M; Doğan R
    Tuberk Toraks; 2009; 57(1):81-3. PubMed ID: 19533443
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Inadvertent passage of a pulmonary artery catheter from the superior vena cava through the left atrium and left ventricle into the aorta.
    Allyn J; Lichtenstein A; Koski EG; Jacobs ML; Lowenstein E
    Anesthesiology; 1989 Jun; 70(6):1019-21. PubMed ID: 2658687
    [No Abstract]   [Full Text] [Related]  

  • 18. Percutaneous fluoroscopic removal of a knotted Swan-Ganz catheter in a patient with a persistent left-sided superior vena cava.
    Ranatunga D; Richardson M; Brooks D
    Australas Radiol; 2007 Apr; 51(2):182-5. PubMed ID: 17419868
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Severe Tricuspid Regurgitation After Percutaneous Removal of a Swan-Ganz Catheter Caught by Suture.
    Gennari M; Bartorelli AL; Polvani G; Muratori M; Ferrari C; Penza E; Arlati FG; Agrifoglio M
    Ann Thorac Surg; 2017 Sep; 104(3):e225-e226. PubMed ID: 28838512
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Transesophageal echocardiographic diagnosis of intracardiac entrapment of a Swan-Ganz catheter in open heart operation.
    Wang HJ; Wang SS; Liau CS
    J Am Soc Echocardiogr; 2004 Mar; 17(3):277-9. PubMed ID: 14981428
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.