These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 15732229)

  • 1. Sonovue improves endocardial border detection and variability in assessing wall motion score and ejection fraction during stress echocardiography.
    Brown AS; Calachanis M; Evdoridis C; Hancock J; Wild S; Prasan A; Nihoyannopoulos P; Monaghan MJ
    Ir J Med Sci; 2004; 173(1):13-7. PubMed ID: 15732229
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Assessment of left ventricular wall motion and delineation of the endocardial border after intravenous injection of Infoson during dobutamine stress echocardiography.
    Ikonomidis I; Holmes E; Narbuvold H; Bolstad B; Muan B; Nihoyannopoulos P
    Coron Artery Dis; 1998; 9(9):567-76. PubMed ID: 9861518
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Enhanced left ventricular endocardial border delineation with an intravenous injection of SonoVue, a new echocardiographic contrast agent: A European multicenter study.
    Senior R; Andersson O; Caidahl K; Carlens P; Herregods MC; Jenni R; Kenny A; Melcher A; Svedenhag J; Vanoverschelde JL; Wandt B; Widgren BR; Williams G; Guerret P; la Rosee K; Agati L; Bezante G
    Echocardiography; 2000 Nov; 17(8):705-11. PubMed ID: 11153016
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Transpulmonary contrast echocardiography: effects on delineation of endocardial border, assessment of wall motion and interobserver variability in stress echocardiograms of limited image quality.
    Schnaack SD; Siegmund P; Spes CH; Tammen AR; Theisen K; Angermann CE
    Coron Artery Dis; 2000 Oct; 11(7):549-54. PubMed ID: 11023243
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Analysis of regional wall motion during contrast-enhanced dobutamine stress echocardiography: effect of contrast imaging settings.
    Cosyns B; Van Camp G; Droogmans S; Weytjens C; Schoors D; Lancellotti P
    Eur J Echocardiogr; 2009 Dec; 10(8):956-60. PubMed ID: 19773247
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [The effect of SonoVue in endocardial border delineation and myocardial perfusion].
    Fang LG;
    Zhonghua Nei Ke Za Zhi; 2004 Nov; 43(11):824-7. PubMed ID: 15634541
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The feasibility and usefulness of contrast exercise echocardiography for the assessment of left ventricular function in master athletes.
    Rizzo M; Vono MC; Toncelli L; Peçagna P; Manetti P; Stefani L; Galanti G
    Eur J Echocardiogr; 2005 Jan; 6(1):24-30. PubMed ID: 15664550
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dobutamine stress echocardiography: improved endocardial border definition and wall motion analysis with tissue harmonic imaging.
    Zaglavara T; Norton M; Cumberledge B; Morris D; Irvine T; Cummins C; Schuster J; Kenny A
    J Am Soc Echocardiogr; 1999 Sep; 12(9):706-13. PubMed ID: 10477414
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The potential clinical value of contrast-enhanced echocardiography beyond current recommendations.
    Larsson MK; Da Silva C; Gunyeli E; Ilami AA; Szummer K; Winter R; Bjällmark A
    Cardiovasc Ultrasound; 2016 Jan; 14():2. PubMed ID: 26729298
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Contrast echocardiography is superior to tissue harmonics for assessment of left ventricular function in mechanically ventilated patients.
    Kornbluth M; Liang DH; Brown P; Gessford E; Schnittger I
    Am Heart J; 2000 Aug; 140(2):291-6. PubMed ID: 10925345
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Improved assessment of the left ventricular endocardial border by intravenous injection of a left heart contrast agent].
    Dittmann H; Razwan E; Greis C; Seipel L
    Ultraschall Med; 1999 Oct; 20(5):185-90. PubMed ID: 10595386
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Endocardial border delineation during dobutamine infusion using contrast echocardiography.
    Mathias W; Arruda AL; Andrade JL; Filho OC; Porter TR
    Echocardiography; 2002 Feb; 19(2):109-14. PubMed ID: 11926972
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of sulfur hexafluoride microbubble (SonoVue)-enhanced myocardial contrast echocardiography with gated single-photon emission computed tomography for detection of significant coronary artery disease: a large European multicenter study.
    Senior R; Moreo A; Gaibazzi N; Agati L; Tiemann K; Shivalkar B; von Bardeleben S; Galiuto L; Lardoux H; Trocino G; Carrió I; Le Guludec D; Sambuceti G; Becher H; Colonna P; Ten Cate F; Bramucci E; Cohen A; Bezante G; Aggeli C; Kasprzak JD
    J Am Coll Cardiol; 2013 Oct; 62(15):1353-61. PubMed ID: 23770168
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of intravenous contrast for left ventricular opacification and border definition on sensitivity and specificity of dobutamine stress echocardiography compared with coronary angiography in technically difficult patients.
    Dolan MS; Riad K; El-Shafei A; Puri S; Tamirisa K; Bierig M; St Vrain J; McKinney L; Havens E; Habermehl K; Pyatt L; Kern M; Labovitz AJ
    Am Heart J; 2001 Nov; 142(5):908-15. PubMed ID: 11685180
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Usefulness of ultrasound contrast for image enhancement during stress echocardiography.
    Ten Cate FJ
    Echocardiography; 2002 Oct; 19(7 Pt 2):621-5. PubMed ID: 12401138
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reproducibility of stress echocardiography using intravenous injection of ultrasound contrast agent (BY 963).
    Leischik R; Kuhlmann C; Bruch C; Jeremias A; Buck T; Erbel R
    Int J Card Imaging; 1997 Oct; 13(5):387-94. PubMed ID: 9360175
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Contrast echocardiography improves interobserver agreement for wall motion score index and correlation with ejection fraction.
    Galema TW; van de Ven AR; Soliman OI; van Domburg RT; Vletter WB; van Dalen BM; Nemes A; ten Cate FJ; Geleijnse ML
    Echocardiography; 2011 May; 28(5):575-81. PubMed ID: 21535116
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Diagnostic efficacy of SonoVue.
    Bokor D
    Am J Cardiol; 2000 Aug; 86(4A):19G-24G. PubMed ID: 10997347
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Native tissue second harmonic imaging improves endocardial and epicardial border definition in dobutamine stress echocardiography.
    Nixdorff U; Matschke C; Winklmaier M; Flachskampf FA; Ludwig J; Pohle K; Land M; Gefeller O; Daniel WG
    Eur J Echocardiogr; 2001 Mar; 2(1):52-61. PubMed ID: 11882426
    [TBL] [Abstract][Full Text] [Related]  

  • 20. High-definition blood flow imaging in the assessment of left ventricular function: Initial experience and comparison with contrast echocardiography.
    Wu G; Xie T; Dimaano MM; Alghrouz MI; Ahmad M
    Echocardiography; 2019 Mar; 36(3):546-557. PubMed ID: 30786059
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.