943 related articles for article (PubMed ID: 15733788)
1. Effects of coil dimensions and field polarization on RF heating inside a head phantom.
Kangarlu A; Ibrahim TS; Shellock FG
Magn Reson Imaging; 2005 Jan; 23(1):53-60. PubMed ID: 15733788
[TBL] [Abstract][Full Text] [Related]
2. 8.0-Tesla human MR system: temperature changes associated with radiofrequency-induced heating of a head phantom.
Kangarlu A; Shellock FG; Chakeres DW
J Magn Reson Imaging; 2003 Feb; 17(2):220-6. PubMed ID: 12541230
[TBL] [Abstract][Full Text] [Related]
3. In-depth study of the electromagnetics of ultrahigh-field MRI.
Ibrahim TS; Mitchell C; Abraham R; Schmalbrock P
NMR Biomed; 2007 Feb; 20(1):58-68. PubMed ID: 17006885
[TBL] [Abstract][Full Text] [Related]
4. Variability in RF-induced heating of a deep brain stimulation implant across MR systems.
Baker KB; Tkach JA; Phillips MD; Rezai AR
J Magn Reson Imaging; 2006 Dec; 24(6):1236-42. PubMed ID: 17078088
[TBL] [Abstract][Full Text] [Related]
5. On the effect of resistive EEG electrodes and leads during 7 T MRI: simulation and temperature measurement studies.
Angelone LM; Vasios CE; Wiggins G; Purdon PL; Bonmassar G
Magn Reson Imaging; 2006 Jul; 24(6):801-12. PubMed ID: 16824975
[TBL] [Abstract][Full Text] [Related]
6. Magnetic resonance safety testing of a newly-developed fiber-optic cardiac pacing lead.
Greatbatch W; Miller V; Shellock FG
J Magn Reson Imaging; 2002 Jul; 16(1):97-103. PubMed ID: 12112509
[TBL] [Abstract][Full Text] [Related]
7. Bilateral neurostimulation systems used for deep brain stimulation: in vitro study of MRI-related heating at 1.5 T and implications for clinical imaging of the brain.
Bhidayasiri R; Bronstein JM; Sinha S; Krahl SE; Ahn S; Behnke EJ; Cohen MS; Frysinger R; Shellock FG
Magn Reson Imaging; 2005 May; 23(4):549-55. PubMed ID: 15919600
[TBL] [Abstract][Full Text] [Related]
8. Spatial distribution of high-frequency electromagnetic energy in human head during MRI: numerical results and measurements.
Simunić D; Wach P; Renhart W; Stollberger R
IEEE Trans Biomed Eng; 1996 Jan; 43(1):88-94. PubMed ID: 8567009
[TBL] [Abstract][Full Text] [Related]
9. In vitro investigation of pacemaker lead heating induced by magnetic resonance imaging: role of implant geometry.
Calcagnini G; Triventi M; Censi F; Mattei E; Bartolini P; Kainz W; Bassen HI
J Magn Reson Imaging; 2008 Oct; 28(4):879-86. PubMed ID: 18821629
[TBL] [Abstract][Full Text] [Related]
10. Finite volume analysis of temperature effects induced by active MRI implants: 2. Defects on active MRI implants causing hot spots.
Busch MH; Vollmann W; Grönemeyer DH
Biomed Eng Online; 2006 May; 5():35. PubMed ID: 16729878
[TBL] [Abstract][Full Text] [Related]
11. An eight-channel phased array RF coil for spine MR imaging at 7 T.
Kraff O; Bitz AK; Kruszona S; Orzada S; Schaefer LC; Theysohn JM; Maderwald S; Ladd ME; Quick HH
Invest Radiol; 2009 Nov; 44(11):734-40. PubMed ID: 19809342
[TBL] [Abstract][Full Text] [Related]
12. Electric field measurements and computational modeling at ultrahigh-field MRI.
Kangarlu A; Tang L; Ibrahim TS
Magn Reson Imaging; 2007 Oct; 25(8):1222-6. PubMed ID: 17368794
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of specific absorption rate as a dosimeter of MRI-related implant heating.
Baker KB; Tkach JA; Nyenhuis JA; Phillips M; Shellock FG; Gonzalez-Martinez J; Rezai AR
J Magn Reson Imaging; 2004 Aug; 20(2):315-20. PubMed ID: 15269959
[TBL] [Abstract][Full Text] [Related]
14. Simple design changes to wires to substantially reduce MRI-induced heating at 1.5 T: implications for implanted leads.
Gray RW; Bibens WT; Shellock FG
Magn Reson Imaging; 2005 Oct; 23(8):887-91. PubMed ID: 16275428
[TBL] [Abstract][Full Text] [Related]
15. Reduction of implant RF heating through modification of transmit coil electric field.
Eryaman Y; Akin B; Atalar E
Magn Reson Med; 2011 May; 65(5):1305-13. PubMed ID: 21500259
[TBL] [Abstract][Full Text] [Related]
16. An inverse design of an open, head/neck RF coil for MRI.
Lawrence BG; Crozier S; Cowin G; Yau DD
IEEE Trans Biomed Eng; 2002 Sep; 49(9):1024-30. PubMed ID: 12214874
[TBL] [Abstract][Full Text] [Related]
17. Design and performance issues of RF coils utilized in ultra high field MRI: experimental and numerical evaluations.
Ibrahim TS; Kangarlu A; Chakeress DW
IEEE Trans Biomed Eng; 2005 Jul; 52(7):1278-84. PubMed ID: 16041991
[TBL] [Abstract][Full Text] [Related]
18. Ocular effects of radiofrequency energy.
Elder JA
Bioelectromagnetics; 2003; Suppl 6():S148-61. PubMed ID: 14628311
[TBL] [Abstract][Full Text] [Related]
19. Temperature and SAR calculations for a human head within volume and surface coils at 64 and 300 MHz.
Collins CM; Liu W; Wang J; Gruetter R; Vaughan JT; Ugurbil K; Smith MB
J Magn Reson Imaging; 2004 May; 19(5):650-6. PubMed ID: 15112317
[TBL] [Abstract][Full Text] [Related]
20. Reducing SAR in parallel excitation using variable-density spirals: a simulation-based study.
Liu Y; Feng K; McDougall MP; Wright SM; Ji J
Magn Reson Imaging; 2008 Oct; 26(8):1122-32. PubMed ID: 18440750
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]