297 related articles for article (PubMed ID: 15736567)
21. Morphologic and histologic findings in bioprosthetic valves explanted from the mitral position in children younger than 5 years of age.
Gellis L; Baird CW; Emani S; Borisuk M; Gauvreau K; Padera RF; Sanders SP
J Thorac Cardiovasc Surg; 2018 Feb; 155(2):746-752. PubMed ID: 29102206
[TBL] [Abstract][Full Text] [Related]
22. 5-year experience with transcatheter transapical mitral valve-in-valve implantation for bioprosthetic valve dysfunction.
Cheung A; Webb JG; Barbanti M; Freeman M; Binder RK; Thompson C; Wood DA; Ye J
J Am Coll Cardiol; 2013 Apr; 61(17):1759-66. PubMed ID: 23500301
[TBL] [Abstract][Full Text] [Related]
23. Porcine versus pericardial bioprostheses: eleven-year follow up of a prospective randomized trial.
Chaudhry MA; Raco L; Muriithi EW; Bernacca GM; Tolland MM; Wheatley DJ
J Heart Valve Dis; 2000 May; 9(3):429-37; discussion 437-8. PubMed ID: 10888102
[TBL] [Abstract][Full Text] [Related]
24. Long-term performance of prostheses in mitral valve replacement.
Moffatt-Bruce SD; Jamieson WR
J Cardiovasc Surg (Torino); 2004 Oct; 45(5):427-47. PubMed ID: 15736566
[TBL] [Abstract][Full Text] [Related]
25. Comparison of reoperation findings of the Carpentier-Edwards (standard) bioprosthesis and the St Jude bioimplant (formerly Liotta) in the mitral position.
Yamak B; Ozsöyler ; Ulus AT; Kiziltepe U; Katircioğlu SF; Taşdemir O
Cardiovasc Surg; 1999 Dec; 7(7):730-4. PubMed ID: 10639048
[TBL] [Abstract][Full Text] [Related]
26. Accelerated degeneration of a bovine pericardial bioprosthetic aortic valve in children and young adults.
Saleeb SF; Newburger JW; Geva T; Baird CW; Gauvreau K; Padera RF; Del Nido PJ; Borisuk MJ; Sanders SP; Mayer JE
Circulation; 2014 Jul; 130(1):51-60. PubMed ID: 24756063
[TBL] [Abstract][Full Text] [Related]
27. Patterns of failure in Hancock pericardial bioprostheses.
Walley VM; Rubens FD; Campagna M; Pipe AL; Keon WJ
J Thorac Cardiovasc Surg; 1991 Aug; 102(2):187-94. PubMed ID: 1865694
[TBL] [Abstract][Full Text] [Related]
28. Mitroflow pericardial bioprosthesis: structured failure at 4.5 years.
Butany J; Feng T; Suri R; Law K; Christakis G
Cardiovasc Pathol; 2012; 21(6):506-10. PubMed ID: 23137773
[TBL] [Abstract][Full Text] [Related]
29. Clinical and Doppler echocardiographic evaluation of bioprosthetic valve failure after 10 years.
Teoh KH; Ivanov J; Weisel RD; Daniel LB; Darcel IC; Rakowski H
Circulation; 1990 Nov; 82(5 Suppl):IV110-6. PubMed ID: 2225395
[TBL] [Abstract][Full Text] [Related]
30. Mitral Valve Replacement Using Carpentier-Edwards Pericardial Bioprosthesis in Patients With Rheumatic Heart Disease Aged Below 40 Years: 17-Year Results.
Chowdhury UK; Rizvi A; Narang R; Seth S; Kalaivani M; Hasija S; Kumari L
Heart Lung Circ; 2018 Jul; 27(7):864-871. PubMed ID: 29029949
[TBL] [Abstract][Full Text] [Related]
31. Long-term follow-up of the Ionescu-Shiley mitral pericardial xenograft.
Gabbay S; Bortolotti U; Wasserman F; Tindel N; Factor SM; Frater RW
J Thorac Cardiovasc Surg; 1984 Nov; 88(5 Pt 1):758-63. PubMed ID: 6492841
[TBL] [Abstract][Full Text] [Related]
32. [Late-occurrence hemolytic anemia after mitral valve bioprosthesis. 2 cases].
Piquemal R; Fauchier L; Regimbeau C; Babuty D; Neville P; Renard JP
Arch Mal Coeur Vaiss; 1998 Jul; 91(7):879-81. PubMed ID: 9749180
[TBL] [Abstract][Full Text] [Related]
33. A morphologic study of Carpentier-Edwards pericardial xenografts in the mitral position exhibiting primary tissue failure in adults in comparison with Ionescu-Shiley pericardial xenografts.
Machida H; Ishibashi-Ueda H; Nakano K; Sasako Y; Kobayashi J; Bando K; Minatoya K; Imamura H; Kitamura S
J Thorac Cardiovasc Surg; 2001 Oct; 122(4):649-55. PubMed ID: 11581594
[TBL] [Abstract][Full Text] [Related]
34. Rest and exercise hemodynamics following aortic valve replacement. A comparison between 19 and 21 mm Ionescu-Shiley pericardial and Carpentier-Edwards porcine valves.
Bove EL; Marvasti MA; Potts JL; Reger MJ; Zamora JL; Eich RH; Parker FB
J Thorac Cardiovasc Surg; 1985 Nov; 90(5):750-5. PubMed ID: 4058047
[TBL] [Abstract][Full Text] [Related]
35. Early mechanical failures of the Hancock pericardial xenograft.
Bortolotti U; Milano A; Thiene G; Guerra F; Mazzucco A; Valente M; Talenti E; Gallucci V
J Thorac Cardiovasc Surg; 1987 Aug; 94(2):200-7. PubMed ID: 3613618
[TBL] [Abstract][Full Text] [Related]
36. [Sorin-Pericarbon pericardial bioprosthesis. A 4-year follow-up study].
Wallnberger E; Jault F; Fontanel M; Nataf P; Cantoni M; Pavie A; Cabrol C; Gandjbakhch I
Arch Mal Coeur Vaiss; 1994 Mar; 87(3):325-8. PubMed ID: 7832619
[TBL] [Abstract][Full Text] [Related]
37. Survival and bioprosthetic valve failure. Ten-year follow-up.
Teoh KH; Ivanov J; Weisel RD; Darcel IC; Rakowski H
Circulation; 1989 Sep; 80(3 Pt 1):I8-15. PubMed ID: 2766540
[TBL] [Abstract][Full Text] [Related]
38. Aortic valve replacement with new-generation stentless pericardial valves: short-term clinical and hemodynamic results.
Grubitzsch H; Linneweber J; Kossagk C; Sanli E; Beholz S; Konertz WF
J Heart Valve Dis; 2005 Sep; 14(5):623-9. PubMed ID: 16245501
[TBL] [Abstract][Full Text] [Related]
39. An eight-year experience with porcine bioprosthetic cardiac valves.
Hartz RS; Fisher EB; Finkelmeier B; DeBoer A; Sanders JH; Moran JM; Michaelis LL
J Thorac Cardiovasc Surg; 1986 Jun; 91(6):910-7. PubMed ID: 3713240
[TBL] [Abstract][Full Text] [Related]
40. [Re-operation of a mitral porcine bioprosthesis 22-years after implantation].
Soeda M; Hata H; Iida M; Kimura H
Kyobu Geka; 2009 Feb; 62(2):149-51. PubMed ID: 19202937
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]