168 related articles for article (PubMed ID: 15741805)
1. Usefulness of lyophilized calibration plasmas for International Normalized Ratio determination with the bovine combined thromboplastin (Thrombotest): results of a collaborative study.
Chantarangkul V; Frontoni R; Gresele P; Oca G; Paniccia R; Pellegrini L; Tripodi A
Blood Coagul Fibrinolysis; 2005 Mar; 16(2):157-63. PubMed ID: 15741805
[TBL] [Abstract][Full Text] [Related]
2. Assignment of international normalized ratio to frozen and freeze-dried pooled plasmas.
van den Besselaar AMHP; Cobbaert CM
Clin Chem Lab Med; 2020 Nov; 58(12):2089-2097. PubMed ID: 32840098
[TBL] [Abstract][Full Text] [Related]
3. Use of lyophilized calibrant plasmas for simplified international normalized ratio determination with a human tissue factor thromboplastin reagent derived from cultured human cells.
van den Besselaar AM; Houdijk WP
Clin Chem; 2003 Dec; 49(12):2006-11. PubMed ID: 14633871
[TBL] [Abstract][Full Text] [Related]
4. Guidelines on preparation, certification, and use of certified plasmas for ISI calibration and INR determination.
van den Besselaar AM; Barrowcliffe TW; Houbouyan-Réveillard LL; Jespersen J; Johnston M; Poller L; Tripodi A;
J Thromb Haemost; 2004 Nov; 2(11):1946-53. PubMed ID: 15550026
[TBL] [Abstract][Full Text] [Related]
5. Field study of lyophilized calibrant plasmas for fresh plasma INR determination.
van den Besselaar AM; Houbouyan-Réveillard LL
Thromb Haemost; 2002 Feb; 87(2):277-81. PubMed ID: 11859852
[TBL] [Abstract][Full Text] [Related]
6. Simplified method for international normalized ratio (INR) derivation based on the prothrombin time/INR line: an international study.
Poller L; Ibrahim S; Keown M; Pattison A; Jespersen J
Clin Chem; 2010 Oct; 56(10):1608-17. PubMed ID: 20798354
[TBL] [Abstract][Full Text] [Related]
7. A comparison of INRs after local calibration of thromboplastin international sensitivity indexes.
McGlasson DL
Clin Lab Sci; 2002; 15(2):91-5. PubMed ID: 12776770
[TBL] [Abstract][Full Text] [Related]
8. A comparison of lyophilized artificially depleted plasmas and lyophilized plasmas from patients receiving warfarin in correcting for coagulometer effects on international normalized ratios.
Poller L; Triplett DA; Hirsh J; Carroll J; Clarke K
Am J Clin Pathol; 1995 Mar; 103(3):366-71. PubMed ID: 7872262
[TBL] [Abstract][Full Text] [Related]
9. Calibration of local systems with lyophilized calibrant plasmas improves the interlaboratory variability of the INR in the Italian external quality assessment scheme.
Chantarangkul V; Tripodi A; Cesana BM; Mannucci PM
Thromb Haemost; 1999 Dec; 82(6):1621-6. PubMed ID: 10613645
[TBL] [Abstract][Full Text] [Related]
10. Multicenter evaluation of lyophilized and deep-frozen plasmas for assignment of the International Normalized Ratio.
van den Besselaar AM; Houbouyan-Reveillard LL; Aillaud MF; Denson KW; Droullé C; Johnston M; Kitchen S; Lindahl TL; Marren M; Martinuzzo ME; Tripodi A; Vergnes C
Thromb Haemost; 1999 Nov; 82(5):1451-5. PubMed ID: 10595637
[TBL] [Abstract][Full Text] [Related]
11. Use of INR calibrator plasmas in the routine coagulation laboratory: a study of two thrombolastin reagents.
Fattorini A; Pattarini E; Viganò S; Crippa L; D'Angelo A
Thromb Res; 2012 Sep; 130(3):e158-62. PubMed ID: 22682443
[TBL] [Abstract][Full Text] [Related]
12. An international collaborative study on the INR calibration of freeze-dried reference plasmas.
Hubbard AR; Margetts SM; Weller LJ; Macnab J; Barrowcliffe TW
Br J Haematol; 1999 Mar; 104(3):455-60. PubMed ID: 10086778
[TBL] [Abstract][Full Text] [Related]
13. The prothrombin time/international normalized ratio (PT/INR) Line: derivation of local INR with commercial thromboplastins and coagulometers--two independent studies.
Poller L; Ibrahim S; Keown M; Pattison A; Jespersen J;
J Thromb Haemost; 2011 Jan; 9(1):140-8. PubMed ID: 20942851
[TBL] [Abstract][Full Text] [Related]
14. Discrepant sensitivity of thromboplastin reagents to clotting factor levels explored by the prothrombin time in patients on stable oral anticoagulant treatment: impact on the international normalized ratio system.
Testa S; Morstabilini G; Fattorini A; Galli L; Denti N; D'Angelo A
Haematologica; 2002 Dec; 87(12):1265-73. PubMed ID: 12495900
[TBL] [Abstract][Full Text] [Related]
15. The European Concerted Action on Anticoagulation (ECAA): field studies of coagulometer effects on the ISI of ECAA thromboplastins.
Poller L; van den Besselaar AM; Jespersen J; Tripodi A; Houghton D
Thromb Haemost; 1998 Oct; 80(4):615-23. PubMed ID: 9798981
[TBL] [Abstract][Full Text] [Related]
16. Improving the inter-laboratory harmonization of the international normalized ratio (INR): utilizing the concept of transference to estimate and/or validate international sensitivity index (ISI) and mean normal prothrombin time (MNPT) values and/or to eliminate measurement bias.
Favaloro EJ; McVicker W; Zhang Y; Hamdam S; Huynh M; Peris P; O'Neal M; Hocker N
Clin Lab Sci; 2012; 25(1):13-25. PubMed ID: 22458045
[TBL] [Abstract][Full Text] [Related]
17. Evaluation of frozen plasma calibrants for enhanced standardization of the international normalized ratio (INR): a multi-center study.
Adcock DM; Johnston M
Thromb Haemost; 2002 Jan; 87(1):74-9. PubMed ID: 11848460
[TBL] [Abstract][Full Text] [Related]
18. Standardization of coagulation tests.
Opartkiattikul N
Southeast Asian J Trop Med Public Health; 1999; 30 Suppl 3():79-85. PubMed ID: 10926265
[TBL] [Abstract][Full Text] [Related]
19. The value of plasma calibrants in correcting coagulometer effects on international normalized ratios. An international multicenter study.
Poller L; Triplett DA; Hirsh J; Carroll J; Clarke K
Am J Clin Pathol; 1995 Mar; 103(3):358-65. PubMed ID: 7872261
[TBL] [Abstract][Full Text] [Related]
20. Screening INR deviation of local prothrombin time systems.
Poller L
J Clin Pathol; 1998 May; 51(5):356-9. PubMed ID: 9708200
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]