81 related articles for article (PubMed ID: 15747178)
1. New fast method for determination of number of UHMWPE wear particles.
Slouf M; Sloufová I; Horák Z; Stépánek P; Entlicher G; Krejcík M; Radonský T; Pokorný D; Sosna A
J Mater Sci Mater Med; 2004 Dec; 15(12):1267-78. PubMed ID: 15747178
[TBL] [Abstract][Full Text] [Related]
2. [Method for assessment of distribution of UHMWPE wear particles in periprosthetic tissues in total hip arthroplasty].
Pokorný D; Slouf M; Horák Z; Jahoda D; Entlicher G; Eklová S; Sosna A
Acta Chir Orthop Traumatol Cech; 2006 Aug; 73(4):243-50. PubMed ID: 17026883
[TBL] [Abstract][Full Text] [Related]
3. [New metod for quantification of UHMWPE wear particles around joint replacements].
Pokorný D; Slouf M; Dybal J; Zolotarevová E; Veselý F; Jahoda D; Vavrík P; Landor I; Entlicher G; Sosna A
Acta Chir Orthop Traumatol Cech; 2009 Oct; 76(5):374-81. PubMed ID: 19912700
[TBL] [Abstract][Full Text] [Related]
4. [Distribution of UHMWPE wear particles in periprosthetic tissues of total hip replacements].
Pokorný D; Slouf M; Veselý F; Fulín P; Jahoda D; Sosna A
Acta Chir Orthop Traumatol Cech; 2010 Apr; 77(2):87-92. PubMed ID: 20447349
[TBL] [Abstract][Full Text] [Related]
5. [MORF method for assessment of the size and shape of UHMWPE wear microparticles and nanoparticles in periprosthetic tissues].
Fulín P; Pokorný D; Slouf M; Lapčíková M; Pavlova E; Zolotarevová E
Acta Chir Orthop Traumatol Cech; 2011; 78(2):131-7. PubMed ID: 21575556
[TBL] [Abstract][Full Text] [Related]
6. Isolation of predominantly submicron-sized UHMWPE wear particles from periprosthetic tissues.
Campbell P; Ma S; Yeom B; McKellop H; Schmalzried TP; Amstutz HC
J Biomed Mater Res; 1995 Jan; 29(1):127-31. PubMed ID: 7713952
[TBL] [Abstract][Full Text] [Related]
7. Distribution of polyethylene wear particles and bone fragments in periprosthetic tissue around total hip joint replacements.
Zolotarevova E; Entlicher G; Pavlova E; Slouf M; Pokorny D; Vesely F; Gallo J; Sosna A
Acta Biomater; 2010 Sep; 6(9):3595-600. PubMed ID: 20417318
[TBL] [Abstract][Full Text] [Related]
8. Low-voltage scanning electron microscopic imaging of ultrahigh-molecular-weight polyethylene.
Pienkowski D; Jacob R; Hoglin D; Saum K; Kaufer H; Nicholls PJ
J Biomed Mater Res; 1995 Oct; 29(10):1167-74. PubMed ID: 8557717
[TBL] [Abstract][Full Text] [Related]
9. Preparation of UHMWPE particles and establishment of inverted macrophage cell model to investigate wear particles induced bioactivites.
Fang HW; Ho YC; Yang CB; Liu HL; Ho FY; Lu YC; Ma HM; Huang CH
J Biochem Biophys Methods; 2006 Oct; 68(3):175-87. PubMed ID: 16859749
[TBL] [Abstract][Full Text] [Related]
10. Influence of design and bearing material on polyethylene wear particle generation in total knee replacement.
Utzschneider S; Paulus A; Datz JC; Schroeder C; Sievers B; Wegener B; Jansson V
Acta Biomater; 2009 Sep; 5(7):2495-502. PubMed ID: 19375997
[TBL] [Abstract][Full Text] [Related]
11. Ferrographic analysis of wear particles in arthroplastic joints.
Mears DC; Hanley EN; Rutkowski R; Westcott VC
J Biomed Mater Res; 1978 Nov; 12(6):867-75. PubMed ID: 739018
[TBL] [Abstract][Full Text] [Related]
12. Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulators.
Tipper JL; Galvin AL; Williams S; McEwen HM; Stone MH; Ingham E; Fisher J
J Biomed Mater Res A; 2006 Sep; 78(3):473-80. PubMed ID: 16721797
[TBL] [Abstract][Full Text] [Related]
13. Technique for generating submicrometer ultra high molecular weight polyethylene particles.
Shanbhag AS; Hasselman CT; Rubash HE
J Orthop Res; 1996 Nov; 14(6):1000-4. PubMed ID: 8982145
[TBL] [Abstract][Full Text] [Related]
14. Simple colorimetric methods for determination of sub-milligram amounts of ultra-high molecular weight polyethylene wear particles.
Vesely F; Zolotarevova E; Spundova M; Kaftan F; Slouf M; Entlicher G
Acta Biomater; 2012 May; 8(5):1935-8. PubMed ID: 22289643
[TBL] [Abstract][Full Text] [Related]
15. Inactivation of a subpopulation of human neutrophils by exposure to ultrahigh-molecular-weight polyethylene wear debris.
Bernard L; Vaudaux P; Huggler E; Stern R; Fréhel C; Francois P; Lew D; Hoffmeyer P
FEMS Immunol Med Microbiol; 2007 Apr; 49(3):425-32. PubMed ID: 17343684
[TBL] [Abstract][Full Text] [Related]
16. [Cytokine profile of a human bone marrow cell culture under the influence of UHMW-PE wear particles].
Wilke A; Bartsch I; Kratz M; Jones D; Endres S
Biomed Tech (Berl); 2005 Oct; 50(10):330-6. PubMed ID: 16300048
[TBL] [Abstract][Full Text] [Related]
17. Chondrocyte acting as phagocyte to internalize polyethylene wear particles and leads to the elevations of osteoarthritis associated NO and PGE2.
Chang CH; Fang HW; Ho YC; Huang HT
Biochem Biophys Res Commun; 2008 May; 369(3):884-8. PubMed ID: 18328808
[TBL] [Abstract][Full Text] [Related]
18. The microstructure of ultra-high molecular weight polyethylene used in total joint replacements.
Farrar DF; Brain AA
Biomaterials; 1997 Dec; 18(24):1677-85. PubMed ID: 9613817
[TBL] [Abstract][Full Text] [Related]
19. The combined effects of crosslinking and high crystallinity on the microstructural and mechanical properties of ultra high molecular weight polyethylene.
Simis KS; Bistolfi A; Bellare A; Pruitt LA
Biomaterials; 2006 Mar; 27(9):1688-94. PubMed ID: 16253325
[TBL] [Abstract][Full Text] [Related]
20. Wear of contemporary total knee replacements--a knee simulator study of six current designs.
Utzschneider S; Harrasser N; Schroeder C; Mazoochian F; Jansson V
Clin Biomech (Bristol, Avon); 2009 Aug; 24(7):583-8. PubMed ID: 19450910
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]