These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
182 related articles for article (PubMed ID: 15753751)
1. Ambient isoflurane pollution and isoflurane consumption during intensive care unit sedation with the Anesthetic Conserving Device. Sackey PV; Martling CR; Nise G; Radell PJ Crit Care Med; 2005 Mar; 33(3):585-90. PubMed ID: 15753751 [TBL] [Abstract][Full Text] [Related]
2. Health worker exposure risk during inhalation sedation with sevoflurane using the (AnaConDa®) anaesthetic conserving device. González-Rodríguez R; Muñoz Martínez A; Galan Serrano J; Moral García MV Rev Esp Anestesiol Reanim; 2014 Mar; 61(3):133-9. PubMed ID: 24439525 [TBL] [Abstract][Full Text] [Related]
3. Environmental safety: Air pollution while using MIRUS™ for short-term sedation in the ICU. Herzog-Niescery J; Vogelsang H; Gude P; Seipp HM; Uhl W; Weber TP; Bellgardt M Acta Anaesthesiol Scand; 2019 Jan; 63(1):86-92. PubMed ID: 30088264 [TBL] [Abstract][Full Text] [Related]
4. Prolonged isoflurane sedation of intensive care unit patients with the Anesthetic Conserving Device. Sackey PV; Martling CR; Granath F; Radell PJ Crit Care Med; 2004 Nov; 32(11):2241-6. PubMed ID: 15640636 [TBL] [Abstract][Full Text] [Related]
5. The impact of the anesthetic conserving device on occupational exposure to isoflurane among intensive care healthcare professionals. Herzog-Niescery J; Vogelsang H; Gude P; Seipp HM; Bartz H; Uhl W; Weber TP; Bellgardt M Minerva Anestesiol; 2018 Jan; 84(1):25-32. PubMed ID: 28631452 [TBL] [Abstract][Full Text] [Related]
6. The scavenging of volatile anesthetic agents in the cardiovascular intensive care unit environment: a technical report. Pickworth T; Jerath A; DeVine R; Kherani N; Wąsowicz M Can J Anaesth; 2013 Jan; 60(1):38-43. PubMed ID: 23132045 [TBL] [Abstract][Full Text] [Related]
7. Feasibility and potential cost/benefit of routine isoflurane sedation using an anesthetic-conserving device: a prospective observational study. L'her E; Dy L; Pili R; Prat G; Tonnelier JM; Lefevre M; Renault A; Boles JM Respir Care; 2008 Oct; 53(10):1295-303. PubMed ID: 18811990 [TBL] [Abstract][Full Text] [Related]
8. General anesthesia in the intensive care unit? Is it ready for "prime time"? Maccioli GA; Cohen NH Crit Care Med; 2005 Mar; 33(3):687-8. PubMed ID: 15753774 [No Abstract] [Full Text] [Related]
9. Atmospheric waste isoflurane concentrations using conventional equipment and rat anesthesia protocols. Smith JC; Bolon B Contemp Top Lab Anim Sci; 2002 Mar; 41(2):10-7. PubMed ID: 11958597 [TBL] [Abstract][Full Text] [Related]
10. Evaluation of waste isoflurane gas exposure during rodent surgery in an Australian university. Johnstone KR; Lau C; Whitelaw JL J Occup Environ Hyg; 2017 Dec; 14(12):955-964. PubMed ID: 28837406 [TBL] [Abstract][Full Text] [Related]
11. Halving the volume of AnaConDa: initial clinical experience with a new small-volume anaesthetic reflector in critically ill patients-a quality improvement project. Bomberg H; Meiser F; Zimmer S; Bellgardt M; Volk T; Sessler DI; Groesdonk HV; Meiser A J Clin Monit Comput; 2018 Aug; 32(4):639-646. PubMed ID: 29700664 [TBL] [Abstract][Full Text] [Related]
12. [Exposure of intensive care personnel to isoflurane in long-term sedation]. Hoerauf K; Koller C; Vescia F; Metz C; Hobbhahn J Anasthesiol Intensivmed Notfallmed Schmerzther; 1995 Dec; 30(8):483-7. PubMed ID: 8580241 [TBL] [Abstract][Full Text] [Related]
13. Comparison of three commercially available activated charcoal canisters for passive scavenging of waste isoflurane during conventional rodent anesthesia. Smith JC; Bolon B Contemp Top Lab Anim Sci; 2003 Mar; 42(2):10-5. PubMed ID: 19757618 [TBL] [Abstract][Full Text] [Related]
14. Three cases of PICU sedation with isoflurane delivered by the 'AnaConDa'. Sackey PV; Martling CR; Radell PJ Paediatr Anaesth; 2005 Oct; 15(10):879-85. PubMed ID: 16176317 [TBL] [Abstract][Full Text] [Related]
15. Halving the Volume of AnaConDa: Evaluation of a New Small-Volume Anesthetic Reflector in a Test Lung Model. Bomberg H; Meiser F; Daume P; Bellgardt M; Volk T; Sessler DI; Groesdonk HV; Meiser A Anesth Analg; 2019 Aug; 129(2):371-379. PubMed ID: 29787413 [TBL] [Abstract][Full Text] [Related]
16. Isoflurane Sedation on the ICU in Cardiac Arrest Patients Treated With Targeted Temperature Management: An Observational Propensity-Matched Study. Krannich A; Leithner C; Engels M; Nee J; Petzinka V; Schröder T; Jörres A; Kruse J; Storm C Crit Care Med; 2017 Apr; 45(4):e384-e390. PubMed ID: 27941501 [TBL] [Abstract][Full Text] [Related]
17. [Functioning of the anaesthetic conserving device: aspects to consider for use in inhalational sedation]. Meiser A; Bellgardt M; Vogelsang H; Sirtl C; Weber T Anaesthesist; 2010 Nov; 59(11):1029-40. PubMed ID: 20878139 [TBL] [Abstract][Full Text] [Related]
18. A case report of personal exposures to isoflurane during animal anesthesia procedures. Fay J J Occup Environ Hyg; 2018 Feb; 15(2):99-104. PubMed ID: 29083962 [TBL] [Abstract][Full Text] [Related]
19. Scavenging anesthetic gas from a membrane oxygenator during cardiopulmonary bypass. Homishak M; Widmer S; Stauffer R J Extra Corpor Technol; 1996 Jun; 28(2):88-90. PubMed ID: 10160449 [TBL] [Abstract][Full Text] [Related]
20. Uncontrolled delivery of liquid volatile anaesthetic when using the anaesthetic conserving device. Karnjuš I; Mekiš D; Križmarić M J Clin Monit Comput; 2018 Aug; 32(4):629-638. PubMed ID: 28567612 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]