These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

73 related articles for article (PubMed ID: 1575645)

  • 1. Measurements of computed tomography radiation scatter.
    Van Every B; Petty RJ
    Australas Phys Eng Sci Med; 1992 Mar; 15(1):15-24. PubMed ID: 1575645
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Establishment of scatter factors for use in shielding calculations and risk assessment for computed tomography facilities.
    Wallace H; Martin CJ; Sutton DG; Peet D; Williams JR
    J Radiol Prot; 2012 Mar; 32(1):39-50. PubMed ID: 22327169
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dosimetric characterization of a cone-beam O-arm imaging system.
    Zhang J; Weir V; Fajardo L; Lin J; Hsiung H; Ritenour ER
    J Xray Sci Technol; 2009; 17(4):305-17. PubMed ID: 19923687
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of the CT scatter fractions provided in NCRP Report No. 147 to scanner-specific scatter fractions and the consequences for calculated barrier thickness.
    Larson SC; Goodsitt MM; Christodoulou EG; Larson LS
    Health Phys; 2007 Aug; 93(2):165-70. PubMed ID: 17622822
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms.
    DeMarco JJ; Cagnon CH; Cody DD; Stevens DM; McCollough CH; O'Daniel J; McNitt-Gray MF
    Phys Med Biol; 2005 Sep; 50(17):3989-4004. PubMed ID: 16177525
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A model-based approach of scatter dose contributions and efficiency of apron shielding for radiation protection in CT.
    Weber N; Monnin P; Elandoy C; Ding S
    Phys Med; 2015 Dec; 31(8):889-896. PubMed ID: 26112350
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Efficacy of lower-body shielding in computed tomography fluoroscopy-guided interventions.
    Mahnken AH; Sedlmair M; Ritter C; Banckwitz R; Flohr T
    Cardiovasc Intervent Radiol; 2012 Dec; 35(6):1475-9. PubMed ID: 22231128
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A Monte Carlo study of the energy spectra and transmission characteristics of scattered radiation from x-ray computed tomography.
    Platten DJ
    J Radiol Prot; 2014 Jun; 34(2):445-56. PubMed ID: 24894101
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monte Carlo Modeling of Computed Tomography Ceiling Scatter for Shielding Calculations.
    Edwards S; Schick D
    Health Phys; 2016 Apr; 110(4):328-41. PubMed ID: 26910026
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparative analysis of patient scatter to phantom scatter for computed tomography systems.
    Edwards SM; Schick D
    Phys Eng Sci Med; 2022 Sep; 45(3):883-888. PubMed ID: 35920978
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The contribution of internal scatter to radiation dose during CT scan of the head.
    Chopp M; Ewald L; Hartson M
    Neuroradiology; 1981; 22(3):145-50. PubMed ID: 7312164
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Radiation shielding implications of computed tomography scatter exposure to the floor.
    Langer SG; Gray JE
    Health Phys; 1998 Aug; 75(2):193-6. PubMed ID: 9685075
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effects of scatter in x-ray computed tomography.
    Joseph PM; Spital RD
    Med Phys; 1982; 9(4):464-72. PubMed ID: 7110075
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of scatter doses from a multislice and a single slice CT scanner.
    Burrage JW; Causer DA
    Australas Phys Eng Sci Med; 2006 Sep; 29(3):257-9. PubMed ID: 17058587
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Compton scatter axial tomography with x-rays: SCAT-CAT.
    Brateman L; Jacobs AM; Fitzgerald LT
    Phys Med Biol; 1984 Nov; 29(11):1353-70. PubMed ID: 6505017
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measurement of scattered radiation in a volumetric 64-slice CT scanner using three experimental techniques.
    Akbarzadeh A; Ay MR; Ghadiri H; Sarkar S; Zaidi H
    Phys Med Biol; 2010 Apr; 55(8):2269-80. PubMed ID: 20354280
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new shielding calculation method for X-ray computed tomography regarding scattered radiation.
    Watanabe H; Noto K; Shohji T; Ogawa Y; Fujibuchi T; Yamaguchi I; Hiraki H; Kida T; Sasanuma K; Katsunuma Y; Nakano T; Horitsugi G; Hosono M
    Radiol Phys Technol; 2017 Jun; 10(2):213-226. PubMed ID: 28025782
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Head scatter factors for small MV photon fields. Part I: a comparison of phantom types and methodologies.
    McKerracher C; Thwaites DI
    Radiother Oncol; 2007 Nov; 85(2):277-85. PubMed ID: 17983677
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Constituent components of out-of-field scatter dose for 18-MV intensity modulated radiation therapy versus 3-dimensional conformal radiation therapy: a comparison with 6-MV and implications for carcinogenesis.
    Ruben JD; Smith R; Lancaster CM; Haynes M; Jones P; Panettieri V
    Int J Radiat Oncol Biol Phys; 2014 Nov; 90(3):645-53. PubMed ID: 25084609
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Correction for scattered radiation and other background signals in dual-energy computed tomography material thickness measurements.
    Vetter JR; Holden JE
    Med Phys; 1988; 15(5):726-31. PubMed ID: 3185409
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.