These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

257 related articles for article (PubMed ID: 15756605)

  • 1. Complex tibial plateau fractures treated with Ilizarov external fixator with or without minimal internal fixation.
    El Barbary H; Abdel Ghani H; Misbah H; Salem K
    Int Orthop; 2005 Jun; 29(3):182-5. PubMed ID: 15756605
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Comparative study on internal fixation and external fixation for the treatment of complex tibial plateau fracture].
    Zhuo N; Li Z; Ge J; Lu X
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Aug; 22(8):952-5. PubMed ID: 18773812
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Compartment syndrome in Schatzker type VI plateau fractures and medial condylar fracture-dislocations treated with temporary external fixation.
    Stark E; Stucken C; Trainer G; Tornetta P
    J Orthop Trauma; 2009 Aug; 23(7):502-6. PubMed ID: 19633459
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Treatment of fractures of the tibial plateau (Schatzker VI) with external fixators versus plate osteosynthesis.
    Bove F; Sala F; Capitani P; Thabet AM; Scita V; Spagnolo R
    Injury; 2018 Nov; 49 Suppl 3():S12-S18. PubMed ID: 30415663
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Does Early versus Delayed Spanning External Fixation Impact Complication Rates for High-energy Tibial Plateau and Plafond Fractures?
    Haller JM; Holt D; Rothberg DL; Kubiak EN; Higgins TF
    Clin Orthop Relat Res; 2016 Jun; 474(6):1436-44. PubMed ID: 26481122
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Treatment strategies for complex fractures of the tibial plateau with external circular fixation and limited internal fixation.
    Catagni MA; Ottaviani G; Maggioni M
    J Trauma; 2007 Nov; 63(5):1043-53. PubMed ID: 17993949
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Outcome of open comminuted tibial plateau fractures treated using an external fixator.
    Subasi M; Kapukaya A; Arslan H; Ozkul E; Cebesoy O
    J Orthop Sci; 2007 Jul; 12(4):347-53. PubMed ID: 17657554
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Bicondylar tibial plateau fractures treated with a hybrid ring external fixator: a preliminary study.
    Stamer DT; Schenk R; Staggers B; Aurori K; Aurori B; Behrens FF
    J Orthop Trauma; 1994 Dec; 8(6):455-61. PubMed ID: 7869158
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Small wire external fixation of high energy tibial plateau fractures.
    Mikulak SA; Gold SM; Zinar DM
    Clin Orthop Relat Res; 1998 Nov; (356):230-8. PubMed ID: 9917689
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Open reduction and internal fixation compared with circular fixator application for bicondylar tibial plateau fractures. Results of a multicenter, prospective, randomized clinical trial.
    Canadian Orthopaedic Trauma Society
    J Bone Joint Surg Am; 2006 Dec; 88(12):2613-23. PubMed ID: 17142411
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Open reduction and internal fixation compared with circular fixator application for bicondylar tibial plateau fractures. Surgical technique.
    Hall JA; Beuerlein MJ; McKee MD;
    J Bone Joint Surg Am; 2009 Mar; 91 Suppl 2 Pt 1():74-88. PubMed ID: 19255201
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Functional outcome of tibial plateau fractures treated with the fine-wire fixator.
    Chin TY; Bardana D; Bailey M; Williamson OD; Miller R; Edwards ER; Esser MP
    Injury; 2005 Dec; 36(12):1467-75. PubMed ID: 16243333
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Preoperative Plan with 3D Printing in Internal and External Fixation for Complex Tibial Plateau Fractures.
    Wu WY; Xu WG; Wan CY; Fang M
    Orthop Surg; 2019 Aug; 11(4):560-568. PubMed ID: 31456325
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Schatzker type VI tibial plateau fractures and the Ilizarov circular external fixator.
    Morandi MM; Landi S; Kilaghbian V; Randelli P
    Bull Hosp Jt Dis; 1997; 56(1):46-8. PubMed ID: 9063603
    [No Abstract]   [Full Text] [Related]  

  • 15. Treatment of complex (Schatzker Type VI) fractures of the tibial plateau with circular wire external fixation: retrospective case review.
    Kumar A; Whittle AP
    J Orthop Trauma; 2000; 14(5):339-44. PubMed ID: 10926241
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Outcome of complex tibial plateau fractures with Ilizarov external fixation with or without minimal internal fixation.
    Subramanyam KN; Tammanaiah M; Mundargi AV; Bhoskar RN; Reddy PS
    Chin J Traumatol; 2019 Jun; 22(3):166-171. PubMed ID: 31072699
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Small wire external fixation for high-energy tibial plateau fractures.
    Kataria H; Sharma N; Kanojia RK
    J Orthop Surg (Hong Kong); 2007 Aug; 15(2):137-43. PubMed ID: 17709848
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Staged management of high-energy proximal tibia fractures (OTA types 41): the results of a prospective, standardized protocol.
    Egol KA; Tejwani NC; Capla EL; Wolinsky PL; Koval KJ
    J Orthop Trauma; 2005 Aug; 19(7):448-55; discussion 456. PubMed ID: 16056075
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparative study of the results of compound tibial shaft fractures treated by Ilizarov ring fixators and limb reconstruction system fixators.
    Pal CP; Kumar H; Kumar D; Dinkar KS; Mittal V; Singh NK
    Chin J Traumatol; 2015; 18(6):347-51. PubMed ID: 26917026
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Treatment of high-energy tibia plateau injury with half-ring external fixation combined with minimum internal fixation].
    Xie Z; Wu XH; Wang XQ; Ma SZ; Xu JZ; Li QH
    Nan Fang Yi Ke Da Xue Xue Bao; 2007 Mar; 27(3):371-3. PubMed ID: 17425996
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.